Failed MILLER Banding Complicated by Pseudoaneurysm: Report of a Case
We present a case in which Minimally Invasive Limited Ligation Endoluminal-assisted Revision (MILLER) banding was complicated by the development of a pseudoaneurysm at the site of attempted banding. A patient with a high-flow fistula and symptoms of distal arterial hypoperfusion underwent Miller ban...