Cargando…
Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is th...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MyJove Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672992/ https://www.ncbi.nlm.nih.gov/pubmed/25145990 http://dx.doi.org/10.3791/51419 |
_version_ | 1782404655104393216 |
---|---|
author | Knaak, Jan M. Spetzler, Vinzent N. Goldaracena, Nicolas Louis, Kristine S. Selzner, Nazia Selzner, Markus |
author_facet | Knaak, Jan M. Spetzler, Vinzent N. Goldaracena, Nicolas Louis, Kristine S. Selzner, Nazia Selzner, Markus |
author_sort | Knaak, Jan M. |
collection | PubMed |
description | The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is the utilization of marginal grafts, such as fatty livers, grafts from older donors, or donation after cardiac death (DCD). The current preservation technique of cold static storage is only poorly tolerated by marginal livers resulting in significant organ damage. In addition, cold static organ storage does not allow graft assessment or repair prior to transplantation. These shortcomings of cold static preservation have triggered an interest in warm perfused organ preservation to reduce cold ischemic injury, assess liver grafts during preservation, and explore the opportunity to repair marginal livers prior to transplantation. The optimal pressure and flow conditions, perfusion temperature, composition of the perfusion solution and the need for an oxygen carrier has been controversial in the past. In spite of promising results in several animal studies, the complexity and the costs have prevented a broader clinical application so far. Recently, with enhanced technology and a better understanding of liver physiology during ex vivo perfusion the outcome of warm liver perfusion has improved and consistently good results can be achieved. This paper will provide information about liver retrieval, storage techniques, and isolated liver perfusion in pigs. We will illustrate a) the requirements to ensure sufficient oxygen supply to the organ, b) technical considerations about the perfusion machine and the perfusion solution, and c) biochemical aspects of isolated organs. |
format | Online Article Text |
id | pubmed-4672992 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | MyJove Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46729922015-12-11 Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts Knaak, Jan M. Spetzler, Vinzent N. Goldaracena, Nicolas Louis, Kristine S. Selzner, Nazia Selzner, Markus J Vis Exp Medicine The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is the utilization of marginal grafts, such as fatty livers, grafts from older donors, or donation after cardiac death (DCD). The current preservation technique of cold static storage is only poorly tolerated by marginal livers resulting in significant organ damage. In addition, cold static organ storage does not allow graft assessment or repair prior to transplantation. These shortcomings of cold static preservation have triggered an interest in warm perfused organ preservation to reduce cold ischemic injury, assess liver grafts during preservation, and explore the opportunity to repair marginal livers prior to transplantation. The optimal pressure and flow conditions, perfusion temperature, composition of the perfusion solution and the need for an oxygen carrier has been controversial in the past. In spite of promising results in several animal studies, the complexity and the costs have prevented a broader clinical application so far. Recently, with enhanced technology and a better understanding of liver physiology during ex vivo perfusion the outcome of warm liver perfusion has improved and consistently good results can be achieved. This paper will provide information about liver retrieval, storage techniques, and isolated liver perfusion in pigs. We will illustrate a) the requirements to ensure sufficient oxygen supply to the organ, b) technical considerations about the perfusion machine and the perfusion solution, and c) biochemical aspects of isolated organs. MyJove Corporation 2014-08-13 /pmc/articles/PMC4672992/ /pubmed/25145990 http://dx.doi.org/10.3791/51419 Text en Copyright © 2014, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Medicine Knaak, Jan M. Spetzler, Vinzent N. Goldaracena, Nicolas Louis, Kristine S. Selzner, Nazia Selzner, Markus Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts |
title | Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts |
title_full | Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts |
title_fullStr | Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts |
title_full_unstemmed | Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts |
title_short | Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts |
title_sort | technique of subnormothermic ex vivo liver perfusion for the storage, assessment, and repair of marginal liver grafts |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672992/ https://www.ncbi.nlm.nih.gov/pubmed/25145990 http://dx.doi.org/10.3791/51419 |
work_keys_str_mv | AT knaakjanm techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts AT spetzlervinzentn techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts AT goldaracenanicolas techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts AT louiskristines techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts AT selznernazia techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts AT selznermarkus techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts |