Cargando…

Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts

The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is th...

Descripción completa

Detalles Bibliográficos
Autores principales: Knaak, Jan M., Spetzler, Vinzent N., Goldaracena, Nicolas, Louis, Kristine S., Selzner, Nazia, Selzner, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672992/
https://www.ncbi.nlm.nih.gov/pubmed/25145990
http://dx.doi.org/10.3791/51419
_version_ 1782404655104393216
author Knaak, Jan M.
Spetzler, Vinzent N.
Goldaracena, Nicolas
Louis, Kristine S.
Selzner, Nazia
Selzner, Markus
author_facet Knaak, Jan M.
Spetzler, Vinzent N.
Goldaracena, Nicolas
Louis, Kristine S.
Selzner, Nazia
Selzner, Markus
author_sort Knaak, Jan M.
collection PubMed
description The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is the utilization of marginal grafts, such as fatty livers, grafts from older donors, or donation after cardiac death (DCD). The current preservation technique of cold static storage is only poorly tolerated by marginal livers resulting in significant organ damage. In addition, cold static organ storage does not allow graft assessment or repair prior to transplantation. These shortcomings of cold static preservation have triggered an interest in warm perfused organ preservation to reduce cold ischemic injury, assess liver grafts during preservation, and explore the opportunity to repair marginal livers prior to transplantation. The optimal pressure and flow conditions, perfusion temperature, composition of the perfusion solution and the need for an oxygen carrier has been controversial in the past. In spite of promising results in several animal studies, the complexity and the costs have prevented a broader clinical application so far. Recently, with enhanced technology and a better understanding of liver physiology during ex vivo perfusion the outcome of warm liver perfusion has improved and consistently good results can be achieved. This paper will provide information about liver retrieval, storage techniques, and isolated liver perfusion in pigs. We will illustrate a) the requirements to ensure sufficient oxygen supply to the organ, b) technical considerations about the perfusion machine and the perfusion solution, and c) biochemical aspects of isolated organs.
format Online
Article
Text
id pubmed-4672992
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-46729922015-12-11 Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts Knaak, Jan M. Spetzler, Vinzent N. Goldaracena, Nicolas Louis, Kristine S. Selzner, Nazia Selzner, Markus J Vis Exp Medicine The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is the utilization of marginal grafts, such as fatty livers, grafts from older donors, or donation after cardiac death (DCD). The current preservation technique of cold static storage is only poorly tolerated by marginal livers resulting in significant organ damage. In addition, cold static organ storage does not allow graft assessment or repair prior to transplantation. These shortcomings of cold static preservation have triggered an interest in warm perfused organ preservation to reduce cold ischemic injury, assess liver grafts during preservation, and explore the opportunity to repair marginal livers prior to transplantation. The optimal pressure and flow conditions, perfusion temperature, composition of the perfusion solution and the need for an oxygen carrier has been controversial in the past. In spite of promising results in several animal studies, the complexity and the costs have prevented a broader clinical application so far. Recently, with enhanced technology and a better understanding of liver physiology during ex vivo perfusion the outcome of warm liver perfusion has improved and consistently good results can be achieved. This paper will provide information about liver retrieval, storage techniques, and isolated liver perfusion in pigs. We will illustrate a) the requirements to ensure sufficient oxygen supply to the organ, b) technical considerations about the perfusion machine and the perfusion solution, and c) biochemical aspects of isolated organs. MyJove Corporation 2014-08-13 /pmc/articles/PMC4672992/ /pubmed/25145990 http://dx.doi.org/10.3791/51419 Text en Copyright © 2014, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Medicine
Knaak, Jan M.
Spetzler, Vinzent N.
Goldaracena, Nicolas
Louis, Kristine S.
Selzner, Nazia
Selzner, Markus
Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
title Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
title_full Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
title_fullStr Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
title_full_unstemmed Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
title_short Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
title_sort technique of subnormothermic ex vivo liver perfusion for the storage, assessment, and repair of marginal liver grafts
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672992/
https://www.ncbi.nlm.nih.gov/pubmed/25145990
http://dx.doi.org/10.3791/51419
work_keys_str_mv AT knaakjanm techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts
AT spetzlervinzentn techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts
AT goldaracenanicolas techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts
AT louiskristines techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts
AT selznernazia techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts
AT selznermarkus techniqueofsubnormothermicexvivoliverperfusionforthestorageassessmentandrepairofmarginallivergrafts