Cargando…
Low within- and between-day variability in exposure to new insulin glargine 300 U/ml
AIMS: To characterize the variability in exposure and metabolic effect of insulin glargine 300 U/ml (Gla-300) at steady state in people with type 1 diabetes (T1DM). METHODS: A total of 50 participants with T1DM underwent two 24-h euglycaemic clamps in steady-state conditions after six once-daily adm...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4674964/ https://www.ncbi.nlm.nih.gov/pubmed/25425394 http://dx.doi.org/10.1111/dom.12416 |
Sumario: | AIMS: To characterize the variability in exposure and metabolic effect of insulin glargine 300 U/ml (Gla-300) at steady state in people with type 1 diabetes (T1DM). METHODS: A total of 50 participants with T1DM underwent two 24-h euglycaemic clamps in steady-state conditions after six once-daily administrations of 0.4 U/kg Gla-300 in a double-blind, randomized, two-treatment, two-period, crossover clamp study. Participants were randomized to receive Gla-300 as a standard cartridge formulation in the first treatment period, and as a formulation with enhanced stability through polysorbate-20 addition in the second treatment period, or vice versa. This design allowed the assessment of bioequivalence between formulations and, subsequently, within- and between-day variability. RESULTS: The cumulative exposure and effect of Gla-300 developed linearly over 24 h, and were evenly distributed across 6- and 12-h intervals. Diurnal fluctuation in exposure (within-day variability) was low; the peak-to-trough ratio of insulin concentration profiles was <2, and both the swing and peak-to-trough fluctuation were <1. Day-to-day reproducibility of exposure was high: the between-day within-subject coefficients of variation for total systemic exposure (area under the serum insulin glargine concentration time curve from time 0 to 24 h after dosing) and maximum insulin concentration were 17.4% [95% confidence interval (CI) 15–21] and 33.4% (95% CI 28–41), respectively. Reproducibility of the metabolic effect was lower than that of exposure. CONCLUSIONS: Gla-300 provides predictable, evenly distributed 24-h coverage as a result of low fluctuation and high reproducibility in insulin exposure, and appears suitable for effective basal insulin use. |
---|