Cargando…
Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts
This study aimed to establish feasibility for myocardial speckle tracking (MST) and intra-observer reliability of both MST and tissue velocity imaging (TVI)-derived right ventricular (RV) strain (ϵ) and strain rate (SR) at rest and during upright incremental exercise. RV ϵ and SR were derived using...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bioscientifica Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676466/ https://www.ncbi.nlm.nih.gov/pubmed/26693290 http://dx.doi.org/10.1530/ERP-14-0011 |
_version_ | 1782405182055776256 |
---|---|
author | Lord, Rachel N George, Keith Jones, Helen Somauroo, John Oxborough, David |
author_facet | Lord, Rachel N George, Keith Jones, Helen Somauroo, John Oxborough, David |
author_sort | Lord, Rachel N |
collection | PubMed |
description | This study aimed to establish feasibility for myocardial speckle tracking (MST) and intra-observer reliability of both MST and tissue velocity imaging (TVI)-derived right ventricular (RV) strain (ϵ) and strain rate (SR) at rest and during upright incremental exercise. RV ϵ and SR were derived using both techniques in 19 healthy male participants. MST-derived ϵ and SR were feasible at rest (85% of segments tracked appropriately). Feasibility reduced significantly with progressive exercise intensity (3% of segments tracking appropriately at 90% maximum heart rate (HR(max))). Coefficient of variations (CoVs) of global ϵ values at rest was acceptable for both TVI and MST (7–12%), with low bias and narrow limits of agreement. Global SR data were less reliable for MST compared with TVI as demonstrated with CoV data (systolic SR=15 and 61%, early diastolic SR=16 and 17% and late diastolic SR=26 and 31% respectively). CoVs of global RV ϵ and SR obtained at 50% HR(max) were acceptable using both techniques. As exercise intensity increased to 70 and 90% HR(max), reliability of ϵ and SR values reduced with larger variability in MST. We conclude that RV global and regional ϵ and SR data are feasible, comparable and reliable at rest and at 50% HR(max) using both MST and TVI. Reliability was reduced during higher exercise intensities with only TVI acceptable for clinical and scientific use. |
format | Online Article Text |
id | pubmed-4676466 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Bioscientifica Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-46764662015-12-21 Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts Lord, Rachel N George, Keith Jones, Helen Somauroo, John Oxborough, David Echo Res Pract Research This study aimed to establish feasibility for myocardial speckle tracking (MST) and intra-observer reliability of both MST and tissue velocity imaging (TVI)-derived right ventricular (RV) strain (ϵ) and strain rate (SR) at rest and during upright incremental exercise. RV ϵ and SR were derived using both techniques in 19 healthy male participants. MST-derived ϵ and SR were feasible at rest (85% of segments tracked appropriately). Feasibility reduced significantly with progressive exercise intensity (3% of segments tracking appropriately at 90% maximum heart rate (HR(max))). Coefficient of variations (CoVs) of global ϵ values at rest was acceptable for both TVI and MST (7–12%), with low bias and narrow limits of agreement. Global SR data were less reliable for MST compared with TVI as demonstrated with CoV data (systolic SR=15 and 61%, early diastolic SR=16 and 17% and late diastolic SR=26 and 31% respectively). CoVs of global RV ϵ and SR obtained at 50% HR(max) were acceptable using both techniques. As exercise intensity increased to 70 and 90% HR(max), reliability of ϵ and SR values reduced with larger variability in MST. We conclude that RV global and regional ϵ and SR data are feasible, comparable and reliable at rest and at 50% HR(max) using both MST and TVI. Reliability was reduced during higher exercise intensities with only TVI acceptable for clinical and scientific use. Bioscientifica Ltd 2014-07-28 2014-09-01 /pmc/articles/PMC4676466/ /pubmed/26693290 http://dx.doi.org/10.1530/ERP-14-0011 Text en © 2014 The authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (http://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Research Lord, Rachel N George, Keith Jones, Helen Somauroo, John Oxborough, David Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts |
title | Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts |
title_full | Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts |
title_fullStr | Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts |
title_full_unstemmed | Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts |
title_short | Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts |
title_sort | reproducibility and feasibility of right ventricular strain and strain rate (sr) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue doppler-derived strain and sr in healthy human hearts |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676466/ https://www.ncbi.nlm.nih.gov/pubmed/26693290 http://dx.doi.org/10.1530/ERP-14-0011 |
work_keys_str_mv | AT lordracheln reproducibilityandfeasibilityofrightventricularstrainandstrainratesrasdeterminedbymyocardialspeckletrackingduringhighintensityuprightexerciseacomparisonwithtissuedopplerderivedstrainandsrinhealthyhumanhearts AT georgekeith reproducibilityandfeasibilityofrightventricularstrainandstrainratesrasdeterminedbymyocardialspeckletrackingduringhighintensityuprightexerciseacomparisonwithtissuedopplerderivedstrainandsrinhealthyhumanhearts AT joneshelen reproducibilityandfeasibilityofrightventricularstrainandstrainratesrasdeterminedbymyocardialspeckletrackingduringhighintensityuprightexerciseacomparisonwithtissuedopplerderivedstrainandsrinhealthyhumanhearts AT somauroojohn reproducibilityandfeasibilityofrightventricularstrainandstrainratesrasdeterminedbymyocardialspeckletrackingduringhighintensityuprightexerciseacomparisonwithtissuedopplerderivedstrainandsrinhealthyhumanhearts AT oxboroughdavid reproducibilityandfeasibilityofrightventricularstrainandstrainratesrasdeterminedbymyocardialspeckletrackingduringhighintensityuprightexerciseacomparisonwithtissuedopplerderivedstrainandsrinhealthyhumanhearts |