An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time

BACKGROUND/AIMS: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. METHODS: To evaluate in vit...

Descripción completa

Detalles Bibliográficos
Autores principales: Shinozaki, Satoshi, Miura, Yoshimasa, Ino, Yuji, Shinozaki, Kenjiro, Lefor, Alan Kawarai, Yamamoto, Hironori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Gastrointestinal Endoscopy 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676661/
https://www.ncbi.nlm.nih.gov/pubmed/26668798
http://dx.doi.org/10.5946/ce.2015.48.6.516
_version_ 1782405212315582464
author Shinozaki, Satoshi
Miura, Yoshimasa
Ino, Yuji
Shinozaki, Kenjiro
Lefor, Alan Kawarai
Yamamoto, Hironori
author_facet Shinozaki, Satoshi
Miura, Yoshimasa
Ino, Yuji
Shinozaki, Kenjiro
Lefor, Alan Kawarai
Yamamoto, Hironori
author_sort Shinozaki, Satoshi
collection PubMed
description BACKGROUND/AIMS: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. METHODS: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. RESULTS: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). CONCLUSIONS: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel.
format Online
Article
Text
id pubmed-4676661
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Gastrointestinal Endoscopy
record_format MEDLINE/PubMed
spelling pubmed-46766612015-12-14 An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time Shinozaki, Satoshi Miura, Yoshimasa Ino, Yuji Shinozaki, Kenjiro Lefor, Alan Kawarai Yamamoto, Hironori Clin Endosc Original Article BACKGROUND/AIMS: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. METHODS: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. RESULTS: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). CONCLUSIONS: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel. The Korean Society of Gastrointestinal Endoscopy 2015-11 2015-11-30 /pmc/articles/PMC4676661/ /pubmed/26668798 http://dx.doi.org/10.5946/ce.2015.48.6.516 Text en Copyright © 2015 Korean Society of Gastrointestinal Endoscopy This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Shinozaki, Satoshi
Miura, Yoshimasa
Ino, Yuji
Shinozaki, Kenjiro
Lefor, Alan Kawarai
Yamamoto, Hironori
An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time
title An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time
title_full An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time
title_fullStr An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time
title_full_unstemmed An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time
title_short An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time
title_sort ultrathin endoscope with a 2.4-mm working channel shortens the esophagogastroduodenoscopy time by shortening the suction time
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676661/
https://www.ncbi.nlm.nih.gov/pubmed/26668798
http://dx.doi.org/10.5946/ce.2015.48.6.516
work_keys_str_mv AT shinozakisatoshi anultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT miurayoshimasa anultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT inoyuji anultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT shinozakikenjiro anultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT leforalankawarai anultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT yamamotohironori anultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT shinozakisatoshi ultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT miurayoshimasa ultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT inoyuji ultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT shinozakikenjiro ultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT leforalankawarai ultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime
AT yamamotohironori ultrathinendoscopewitha24mmworkingchannelshortenstheesophagogastroduodenoscopytimebyshorteningthesuctiontime