Cargando…
A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
Spectrometers now offer the field strengths necessary to visualize mammalian cells but were not designed to accommodate imaging of live tissues. As such, spectrometers pose significant challenges—the most evident of which are spatial limitations—to conducting experiments in living tissue. This limit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4678305/ https://www.ncbi.nlm.nih.gov/pubmed/26666980 http://dx.doi.org/10.1038/srep18095 |
_version_ | 1782405431980720128 |
---|---|
author | Flint, Jeremy J. Menon, Kannan Hansen, Brian Forder, John Blackband, Stephen J. |
author_facet | Flint, Jeremy J. Menon, Kannan Hansen, Brian Forder, John Blackband, Stephen J. |
author_sort | Flint, Jeremy J. |
collection | PubMed |
description | Spectrometers now offer the field strengths necessary to visualize mammalian cells but were not designed to accommodate imaging of live tissues. As such, spectrometers pose significant challenges—the most evident of which are spatial limitations—to conducting experiments in living tissue. This limitation becomes problematic upon trying to employ commercial perfusion equipment which is bulky and—being designed almost exclusively for light microscopy or electrophysiology studies—seldom includes MR-compatibility as a design criterion. To overcome problems exclusive to ultra-high magnetic field environments with limited spatial access, we have designed microperfusion and in-bore oxygenation systems capable of interfacing with Bruker’s series of micro surface-coils. These devices are designed for supporting cellular resolution imaging in MR studies of excised, living tissue. The combined system allows for precise control of both dissolved gas and pH levels in the perfusate thus demonstrating applicability for a wide range of tissue types. Its compactness, linear architecture, and MR-compatible material content are key design features intended to provide a versatile hardware interface compatible with any NMR spectrometer. Such attributes will ensure the microperfusion rig’s continued utility as it may be used with a multitude of contemporary NMR systems in addition to those which are currently in development. |
format | Online Article Text |
id | pubmed-4678305 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-46783052015-12-17 A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants Flint, Jeremy J. Menon, Kannan Hansen, Brian Forder, John Blackband, Stephen J. Sci Rep Article Spectrometers now offer the field strengths necessary to visualize mammalian cells but were not designed to accommodate imaging of live tissues. As such, spectrometers pose significant challenges—the most evident of which are spatial limitations—to conducting experiments in living tissue. This limitation becomes problematic upon trying to employ commercial perfusion equipment which is bulky and—being designed almost exclusively for light microscopy or electrophysiology studies—seldom includes MR-compatibility as a design criterion. To overcome problems exclusive to ultra-high magnetic field environments with limited spatial access, we have designed microperfusion and in-bore oxygenation systems capable of interfacing with Bruker’s series of micro surface-coils. These devices are designed for supporting cellular resolution imaging in MR studies of excised, living tissue. The combined system allows for precise control of both dissolved gas and pH levels in the perfusate thus demonstrating applicability for a wide range of tissue types. Its compactness, linear architecture, and MR-compatible material content are key design features intended to provide a versatile hardware interface compatible with any NMR spectrometer. Such attributes will ensure the microperfusion rig’s continued utility as it may be used with a multitude of contemporary NMR systems in addition to those which are currently in development. Nature Publishing Group 2015-12-15 /pmc/articles/PMC4678305/ /pubmed/26666980 http://dx.doi.org/10.1038/srep18095 Text en Copyright © 2015, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Flint, Jeremy J. Menon, Kannan Hansen, Brian Forder, John Blackband, Stephen J. A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants |
title | A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants |
title_full | A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants |
title_fullStr | A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants |
title_full_unstemmed | A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants |
title_short | A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants |
title_sort | microperfusion and in-bore oxygenator system designed for magnetic resonance microscopy studies on living tissue explants |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4678305/ https://www.ncbi.nlm.nih.gov/pubmed/26666980 http://dx.doi.org/10.1038/srep18095 |
work_keys_str_mv | AT flintjeremyj amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT menonkannan amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT hansenbrian amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT forderjohn amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT blackbandstephenj amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT flintjeremyj microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT menonkannan microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT hansenbrian microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT forderjohn microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants AT blackbandstephenj microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants |