A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants

Spectrometers now offer the field strengths necessary to visualize mammalian cells but were not designed to accommodate imaging of live tissues. As such, spectrometers pose significant challenges—the most evident of which are spatial limitations—to conducting experiments in living tissue. This limit...

Descripción completa

Detalles Bibliográficos
Autores principales: Flint, Jeremy J., Menon, Kannan, Hansen, Brian, Forder, John, Blackband, Stephen J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4678305/
https://www.ncbi.nlm.nih.gov/pubmed/26666980
http://dx.doi.org/10.1038/srep18095
_version_ 1782405431980720128
author Flint, Jeremy J.
Menon, Kannan
Hansen, Brian
Forder, John
Blackband, Stephen J.
author_facet Flint, Jeremy J.
Menon, Kannan
Hansen, Brian
Forder, John
Blackband, Stephen J.
author_sort Flint, Jeremy J.
collection PubMed
description Spectrometers now offer the field strengths necessary to visualize mammalian cells but were not designed to accommodate imaging of live tissues. As such, spectrometers pose significant challenges—the most evident of which are spatial limitations—to conducting experiments in living tissue. This limitation becomes problematic upon trying to employ commercial perfusion equipment which is bulky and—being designed almost exclusively for light microscopy or electrophysiology studies—seldom includes MR-compatibility as a design criterion. To overcome problems exclusive to ultra-high magnetic field environments with limited spatial access, we have designed microperfusion and in-bore oxygenation systems capable of interfacing with Bruker’s series of micro surface-coils. These devices are designed for supporting cellular resolution imaging in MR studies of excised, living tissue. The combined system allows for precise control of both dissolved gas and pH levels in the perfusate thus demonstrating applicability for a wide range of tissue types. Its compactness, linear architecture, and MR-compatible material content are key design features intended to provide a versatile hardware interface compatible with any NMR spectrometer. Such attributes will ensure the microperfusion rig’s continued utility as it may be used with a multitude of contemporary NMR systems in addition to those which are currently in development.
format Online
Article
Text
id pubmed-4678305
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-46783052015-12-17 A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants Flint, Jeremy J. Menon, Kannan Hansen, Brian Forder, John Blackband, Stephen J. Sci Rep Article Spectrometers now offer the field strengths necessary to visualize mammalian cells but were not designed to accommodate imaging of live tissues. As such, spectrometers pose significant challenges—the most evident of which are spatial limitations—to conducting experiments in living tissue. This limitation becomes problematic upon trying to employ commercial perfusion equipment which is bulky and—being designed almost exclusively for light microscopy or electrophysiology studies—seldom includes MR-compatibility as a design criterion. To overcome problems exclusive to ultra-high magnetic field environments with limited spatial access, we have designed microperfusion and in-bore oxygenation systems capable of interfacing with Bruker’s series of micro surface-coils. These devices are designed for supporting cellular resolution imaging in MR studies of excised, living tissue. The combined system allows for precise control of both dissolved gas and pH levels in the perfusate thus demonstrating applicability for a wide range of tissue types. Its compactness, linear architecture, and MR-compatible material content are key design features intended to provide a versatile hardware interface compatible with any NMR spectrometer. Such attributes will ensure the microperfusion rig’s continued utility as it may be used with a multitude of contemporary NMR systems in addition to those which are currently in development. Nature Publishing Group 2015-12-15 /pmc/articles/PMC4678305/ /pubmed/26666980 http://dx.doi.org/10.1038/srep18095 Text en Copyright © 2015, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Flint, Jeremy J.
Menon, Kannan
Hansen, Brian
Forder, John
Blackband, Stephen J.
A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
title A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
title_full A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
title_fullStr A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
title_full_unstemmed A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
title_short A Microperfusion and In-Bore Oxygenator System Designed for Magnetic Resonance Microscopy Studies on Living Tissue Explants
title_sort microperfusion and in-bore oxygenator system designed for magnetic resonance microscopy studies on living tissue explants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4678305/
https://www.ncbi.nlm.nih.gov/pubmed/26666980
http://dx.doi.org/10.1038/srep18095
work_keys_str_mv AT flintjeremyj amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT menonkannan amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT hansenbrian amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT forderjohn amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT blackbandstephenj amicroperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT flintjeremyj microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT menonkannan microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT hansenbrian microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT forderjohn microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants
AT blackbandstephenj microperfusionandinboreoxygenatorsystemdesignedformagneticresonancemicroscopystudiesonlivingtissueexplants