Cargando…
The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid?
OBJECTIVE: The abdominal drawing-in manoeuvre (ADIM) is a common clinical tool for manually assessing whether a preferential activation of the deep abdominal muscles in patients with low back pain (LBP) is ‘correct’ or not. The validity and reliability of manual assessment of the ADIM are, however,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4679884/ https://www.ncbi.nlm.nih.gov/pubmed/26656015 http://dx.doi.org/10.1136/bmjopen-2015-008711 |
_version_ | 1782405601297432576 |
---|---|
author | Kaping, Karsten Äng, Björn O Rasmussen-Barr, Eva |
author_facet | Kaping, Karsten Äng, Björn O Rasmussen-Barr, Eva |
author_sort | Kaping, Karsten |
collection | PubMed |
description | OBJECTIVE: The abdominal drawing-in manoeuvre (ADIM) is a common clinical tool for manually assessing whether a preferential activation of the deep abdominal muscles in patients with low back pain (LBP) is ‘correct’ or not. The validity and reliability of manual assessment of the ADIM are, however, as yet unknown. This study evaluated the concurrent and discriminative validity and reliability of the manually assessed ADIM. DESIGN: Single-blinded cross-sectional study. SETTINGS: General population in Stockholm County, Sweden. PARTICIPANTS: The study sample comprised 38 participants seeking care for LBP, and 15 healthy subjects. MEASURES: The manual ADIM was assessed as correct or not following a standard procedure. Ultrasound imaging (USI) was used as the concurrent reference (gold standard) for the manually assessed ADIM by calculating a ratio of the change in muscle thickness between the resting and the contracted states: the correlation between manual test and USI was calculated. Discriminative validity was analysed by calculating sensitivity and specificity. A sample of 24 participants was analysed with κ coefficients for interobserver reliability between two raters. RESULTS: The concurrent validity between the manual ADIM and the ADIM–USI ratios showed poor correlations (r=0.13–0.40). The discriminative validity of the manually assessed ADIM to predict LBP showed a sensitivity/specificity of 0.30/0.73, while the ADIM–USI ratio to predict LBP showed 0.19/0.87. The interobserver reliability for the manually assessed ADIM revealed substantial agreement: K=0.71, CI (95%) 0.41 to 1.00. CONCLUSIONS: Although the interobserver reliability of the manually assessed ADIM was high, the concurrent and discriminative validity were both low for examining the preferential activity of the deep abdominal muscles. Neither the manually assessed ADIM nor the ultrasound testing discriminated between participants with LBP and healthy subjects regarding preferential activity of the transversus muscle as this ability/inability was also present in healthy subjects. |
format | Online Article Text |
id | pubmed-4679884 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-46798842015-12-22 The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? Kaping, Karsten Äng, Björn O Rasmussen-Barr, Eva BMJ Open Rehabilitation Medicine OBJECTIVE: The abdominal drawing-in manoeuvre (ADIM) is a common clinical tool for manually assessing whether a preferential activation of the deep abdominal muscles in patients with low back pain (LBP) is ‘correct’ or not. The validity and reliability of manual assessment of the ADIM are, however, as yet unknown. This study evaluated the concurrent and discriminative validity and reliability of the manually assessed ADIM. DESIGN: Single-blinded cross-sectional study. SETTINGS: General population in Stockholm County, Sweden. PARTICIPANTS: The study sample comprised 38 participants seeking care for LBP, and 15 healthy subjects. MEASURES: The manual ADIM was assessed as correct or not following a standard procedure. Ultrasound imaging (USI) was used as the concurrent reference (gold standard) for the manually assessed ADIM by calculating a ratio of the change in muscle thickness between the resting and the contracted states: the correlation between manual test and USI was calculated. Discriminative validity was analysed by calculating sensitivity and specificity. A sample of 24 participants was analysed with κ coefficients for interobserver reliability between two raters. RESULTS: The concurrent validity between the manual ADIM and the ADIM–USI ratios showed poor correlations (r=0.13–0.40). The discriminative validity of the manually assessed ADIM to predict LBP showed a sensitivity/specificity of 0.30/0.73, while the ADIM–USI ratio to predict LBP showed 0.19/0.87. The interobserver reliability for the manually assessed ADIM revealed substantial agreement: K=0.71, CI (95%) 0.41 to 1.00. CONCLUSIONS: Although the interobserver reliability of the manually assessed ADIM was high, the concurrent and discriminative validity were both low for examining the preferential activity of the deep abdominal muscles. Neither the manually assessed ADIM nor the ultrasound testing discriminated between participants with LBP and healthy subjects regarding preferential activity of the transversus muscle as this ability/inability was also present in healthy subjects. BMJ Publishing Group 2015-12-09 /pmc/articles/PMC4679884/ /pubmed/26656015 http://dx.doi.org/10.1136/bmjopen-2015-008711 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Rehabilitation Medicine Kaping, Karsten Äng, Björn O Rasmussen-Barr, Eva The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
title | The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
title_full | The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
title_fullStr | The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
title_full_unstemmed | The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
title_short | The abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
title_sort | abdominal drawing-in manoeuvre for detecting activity in the deep abdominal muscles: is this clinical tool reliable and valid? |
topic | Rehabilitation Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4679884/ https://www.ncbi.nlm.nih.gov/pubmed/26656015 http://dx.doi.org/10.1136/bmjopen-2015-008711 |
work_keys_str_mv | AT kapingkarsten theabdominaldrawinginmanoeuvrefordetectingactivityinthedeepabdominalmusclesisthisclinicaltoolreliableandvalid AT angbjorno theabdominaldrawinginmanoeuvrefordetectingactivityinthedeepabdominalmusclesisthisclinicaltoolreliableandvalid AT rasmussenbarreva theabdominaldrawinginmanoeuvrefordetectingactivityinthedeepabdominalmusclesisthisclinicaltoolreliableandvalid AT kapingkarsten abdominaldrawinginmanoeuvrefordetectingactivityinthedeepabdominalmusclesisthisclinicaltoolreliableandvalid AT angbjorno abdominaldrawinginmanoeuvrefordetectingactivityinthedeepabdominalmusclesisthisclinicaltoolreliableandvalid AT rasmussenbarreva abdominaldrawinginmanoeuvrefordetectingactivityinthedeepabdominalmusclesisthisclinicaltoolreliableandvalid |