Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
BACKGROUND: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional ra...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Shiraz University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681462/ https://www.ncbi.nlm.nih.gov/pubmed/26688796 |
_version_ | 1782405752875384832 |
---|---|
author | Janbabanezhad Toori, A. Shabestani-Monfared, A. Deevband, M.R. Abdi, R. Nabahati, M. |
author_facet | Janbabanezhad Toori, A. Shabestani-Monfared, A. Deevband, M.R. Abdi, R. Nabahati, M. |
author_sort | Janbabanezhad Toori, A. |
collection | PubMed |
description | BACKGROUND: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. OBJECTIVE: This study is aimed at evaluating radiation dose to patients from Computed Tomography (CT) examination in Mazandaran hospitals and defining diagnostic reference level (DRL). METHODS: Patient-related data on CT protocol for four common CT examinations including brain, sinus, chest and abdomen & pelvic were collected. In each center, Computed Tomography Dose Index (CTDI) measurements were performed using pencil ionization chamber and CT dosimetry phantom according to AAPM report No. 96 for those techniques. Then, Weighted Computed Tomography Dose Index (CTDIW), Volume Computed Tomography Dose Index (CTDI vol) and Dose Length Product (DLP) were calculated. RESULTS: The CTDIw for brain, sinus, chest and abdomen & pelvic ranged (15.6-73), (3.8-25. 8), (4.5-16.3) and (7-16.3), respectively. Values of DLP had a range of (197.4-981), (41.8-184), (131-342.3) and (283.6-486) for brain, sinus, chest and abdomen & pelvic, respectively. The 3rd quartile of CTDIW, derived from dose distribution for each examination is the proposed quantity for DRL. The DRLs of brain, sinus, chest and abdomen & pelvic are measured 59.5, 17, 7.8 and 11 mGy, respectively. CONCLUSION: Results of this study demonstrated large scales of dose for the same examination among different centers. For all examinations, our values were lower than international reference doses. |
format | Online Article Text |
id | pubmed-4681462 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Shiraz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-46814622015-12-18 Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran Janbabanezhad Toori, A. Shabestani-Monfared, A. Deevband, M.R. Abdi, R. Nabahati, M. J Biomed Phys Eng Original Article BACKGROUND: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. OBJECTIVE: This study is aimed at evaluating radiation dose to patients from Computed Tomography (CT) examination in Mazandaran hospitals and defining diagnostic reference level (DRL). METHODS: Patient-related data on CT protocol for four common CT examinations including brain, sinus, chest and abdomen & pelvic were collected. In each center, Computed Tomography Dose Index (CTDI) measurements were performed using pencil ionization chamber and CT dosimetry phantom according to AAPM report No. 96 for those techniques. Then, Weighted Computed Tomography Dose Index (CTDIW), Volume Computed Tomography Dose Index (CTDI vol) and Dose Length Product (DLP) were calculated. RESULTS: The CTDIw for brain, sinus, chest and abdomen & pelvic ranged (15.6-73), (3.8-25. 8), (4.5-16.3) and (7-16.3), respectively. Values of DLP had a range of (197.4-981), (41.8-184), (131-342.3) and (283.6-486) for brain, sinus, chest and abdomen & pelvic, respectively. The 3rd quartile of CTDIW, derived from dose distribution for each examination is the proposed quantity for DRL. The DRLs of brain, sinus, chest and abdomen & pelvic are measured 59.5, 17, 7.8 and 11 mGy, respectively. CONCLUSION: Results of this study demonstrated large scales of dose for the same examination among different centers. For all examinations, our values were lower than international reference doses. Shiraz University of Medical Sciences 2015-12-01 /pmc/articles/PMC4681462/ /pubmed/26688796 Text en © 2015: Journal of Biomedical Physics and Engineering This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported License (http://creativecommons.org/licenses/by/3.0/), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Janbabanezhad Toori, A. Shabestani-Monfared, A. Deevband, M.R. Abdi, R. Nabahati, M. Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran |
title | Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran |
title_full | Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran |
title_fullStr | Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran |
title_full_unstemmed | Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran |
title_short | Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran |
title_sort | dose assessment in computed tomography examination and establishment of local diagnostic reference levels in mazandaran, iran |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681462/ https://www.ncbi.nlm.nih.gov/pubmed/26688796 |
work_keys_str_mv | AT janbabanezhadtooria doseassessmentincomputedtomographyexaminationandestablishmentoflocaldiagnosticreferencelevelsinmazandaraniran AT shabestanimonfareda doseassessmentincomputedtomographyexaminationandestablishmentoflocaldiagnosticreferencelevelsinmazandaraniran AT deevbandmr doseassessmentincomputedtomographyexaminationandestablishmentoflocaldiagnosticreferencelevelsinmazandaraniran AT abdir doseassessmentincomputedtomographyexaminationandestablishmentoflocaldiagnosticreferencelevelsinmazandaraniran AT nabahatim doseassessmentincomputedtomographyexaminationandestablishmentoflocaldiagnosticreferencelevelsinmazandaraniran |