Cargando…
Supine effect of passive cycling movement induces vagal withdrawal
[Purpose] The purpose of this study was to examine changes in vagal tone during passive exercise while supine. [Subjects and Methods] Eleven healthy males lay supine for 5 min and then performed passive cycling for 10 min using a passive cycling machine. The lower legs moved through a range of motio...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681913/ https://www.ncbi.nlm.nih.gov/pubmed/26696706 http://dx.doi.org/10.1589/jpts.27.3397 |
_version_ | 1782405794387460096 |
---|---|
author | Fujita, Daisuke Kubo, Kousei Takagi, Daisuke Nishida, Yuusuke |
author_facet | Fujita, Daisuke Kubo, Kousei Takagi, Daisuke Nishida, Yuusuke |
author_sort | Fujita, Daisuke |
collection | PubMed |
description | [Purpose] The purpose of this study was to examine changes in vagal tone during passive exercise while supine. [Subjects and Methods] Eleven healthy males lay supine for 5 min and then performed passive cycling for 10 min using a passive cycling machine. The lower legs moved through a range of motion defined by 90° and 180° knee joint angles at 60 rpm. Respiratory rates were maintained at 0.25 Hz to elicit respiratory sinus arrhythmia. Heart rate variability was analyzed using the time domain analysis, as the root mean squared standard differences between adjacent R-R intervals (rMSSD), and spectrum domain analysis of the high frequency (HF) component. [Results] Compared to rest, passive cycling decreased rMSSD (rest, 66.6 ± 92.6 ms; passive exercise, 53.5 ± 32.5 ms). However, no significant changes in HR or HF were observed (rest, 68.2 ± 6.9 bpm, 65.6 ± 12.0 n.u.; passive exercise, 70.2 ± 7.2 bpm, 67.9 ± 10.0 n.u.). [Conclusion] These results suggest that passive exercise decreases rMMSD through supine-stimulated mechanoreceptors with no effect on HR or HF. Therefore, rMSSD is not affected by hydrostatic pressure during passive cycling in the supine position. |
format | Online Article Text |
id | pubmed-4681913 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46819132015-12-22 Supine effect of passive cycling movement induces vagal withdrawal Fujita, Daisuke Kubo, Kousei Takagi, Daisuke Nishida, Yuusuke J Phys Ther Sci Original Article [Purpose] The purpose of this study was to examine changes in vagal tone during passive exercise while supine. [Subjects and Methods] Eleven healthy males lay supine for 5 min and then performed passive cycling for 10 min using a passive cycling machine. The lower legs moved through a range of motion defined by 90° and 180° knee joint angles at 60 rpm. Respiratory rates were maintained at 0.25 Hz to elicit respiratory sinus arrhythmia. Heart rate variability was analyzed using the time domain analysis, as the root mean squared standard differences between adjacent R-R intervals (rMSSD), and spectrum domain analysis of the high frequency (HF) component. [Results] Compared to rest, passive cycling decreased rMSSD (rest, 66.6 ± 92.6 ms; passive exercise, 53.5 ± 32.5 ms). However, no significant changes in HR or HF were observed (rest, 68.2 ± 6.9 bpm, 65.6 ± 12.0 n.u.; passive exercise, 70.2 ± 7.2 bpm, 67.9 ± 10.0 n.u.). [Conclusion] These results suggest that passive exercise decreases rMMSD through supine-stimulated mechanoreceptors with no effect on HR or HF. Therefore, rMSSD is not affected by hydrostatic pressure during passive cycling in the supine position. The Society of Physical Therapy Science 2015-11-30 2015-11 /pmc/articles/PMC4681913/ /pubmed/26696706 http://dx.doi.org/10.1589/jpts.27.3397 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. |
spellingShingle | Original Article Fujita, Daisuke Kubo, Kousei Takagi, Daisuke Nishida, Yuusuke Supine effect of passive cycling movement induces vagal withdrawal |
title | Supine effect of passive cycling movement induces vagal
withdrawal |
title_full | Supine effect of passive cycling movement induces vagal
withdrawal |
title_fullStr | Supine effect of passive cycling movement induces vagal
withdrawal |
title_full_unstemmed | Supine effect of passive cycling movement induces vagal
withdrawal |
title_short | Supine effect of passive cycling movement induces vagal
withdrawal |
title_sort | supine effect of passive cycling movement induces vagal
withdrawal |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681913/ https://www.ncbi.nlm.nih.gov/pubmed/26696706 http://dx.doi.org/10.1589/jpts.27.3397 |
work_keys_str_mv | AT fujitadaisuke supineeffectofpassivecyclingmovementinducesvagalwithdrawal AT kubokousei supineeffectofpassivecyclingmovementinducesvagalwithdrawal AT takagidaisuke supineeffectofpassivecyclingmovementinducesvagalwithdrawal AT nishidayuusuke supineeffectofpassivecyclingmovementinducesvagalwithdrawal |