Cargando…
Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
[Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 year...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681948/ https://www.ncbi.nlm.nih.gov/pubmed/26696741 http://dx.doi.org/10.1589/jpts.27.3579 |
_version_ | 1782405802284285952 |
---|---|
author | Jeong, Byoung-Lock Ha, Sung-Min Jeon, In-Cheol Hong, Ki-Hoon |
author_facet | Jeong, Byoung-Lock Ha, Sung-Min Jeon, In-Cheol Hong, Ki-Hoon |
author_sort | Jeong, Byoung-Lock |
collection | PubMed |
description | [Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 years) were recruited via convenience sampling of university students. [Methods] Real-time US measurements of the CSA and MT of the longus colli were recorded. Repeated US measurements using a standard protocol were performed on the same day 1 hour apart to assess intra- and inter-rater reliability. Intra-class correlation coefficients (ICC; 2, 1) were used to determine the intra- and inter-rater reliability of the CSA and MT measurements. [Results] This study demonstrated that the US measurements (0.5 and 1 kg) of the CSA and MT of the longus colli give reliable and consistent results. [Conclusion] Based on these results, a consistent inward pressure of the probe is needed to ensure precise US measurement of the longus colli muscle. |
format | Online Article Text |
id | pubmed-4681948 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46819482015-12-22 Reliability of ultrasonography measurement for the longus colli according to inward probe pressure Jeong, Byoung-Lock Ha, Sung-Min Jeon, In-Cheol Hong, Ki-Hoon J Phys Ther Sci Original Article [Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 years) were recruited via convenience sampling of university students. [Methods] Real-time US measurements of the CSA and MT of the longus colli were recorded. Repeated US measurements using a standard protocol were performed on the same day 1 hour apart to assess intra- and inter-rater reliability. Intra-class correlation coefficients (ICC; 2, 1) were used to determine the intra- and inter-rater reliability of the CSA and MT measurements. [Results] This study demonstrated that the US measurements (0.5 and 1 kg) of the CSA and MT of the longus colli give reliable and consistent results. [Conclusion] Based on these results, a consistent inward pressure of the probe is needed to ensure precise US measurement of the longus colli muscle. The Society of Physical Therapy Science 2015-11-30 2015-11 /pmc/articles/PMC4681948/ /pubmed/26696741 http://dx.doi.org/10.1589/jpts.27.3579 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. |
spellingShingle | Original Article Jeong, Byoung-Lock Ha, Sung-Min Jeon, In-Cheol Hong, Ki-Hoon Reliability of ultrasonography measurement for the longus colli according to inward probe pressure |
title | Reliability of ultrasonography measurement for the longus colli according to
inward probe pressure |
title_full | Reliability of ultrasonography measurement for the longus colli according to
inward probe pressure |
title_fullStr | Reliability of ultrasonography measurement for the longus colli according to
inward probe pressure |
title_full_unstemmed | Reliability of ultrasonography measurement for the longus colli according to
inward probe pressure |
title_short | Reliability of ultrasonography measurement for the longus colli according to
inward probe pressure |
title_sort | reliability of ultrasonography measurement for the longus colli according to
inward probe pressure |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681948/ https://www.ncbi.nlm.nih.gov/pubmed/26696741 http://dx.doi.org/10.1589/jpts.27.3579 |
work_keys_str_mv | AT jeongbyounglock reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure AT hasungmin reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure AT jeonincheol reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure AT hongkihoon reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure |