Cargando…

Reliability of ultrasonography measurement for the longus colli according to inward probe pressure

[Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 year...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Byoung-Lock, Ha, Sung-Min, Jeon, In-Cheol, Hong, Ki-Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681948/
https://www.ncbi.nlm.nih.gov/pubmed/26696741
http://dx.doi.org/10.1589/jpts.27.3579
_version_ 1782405802284285952
author Jeong, Byoung-Lock
Ha, Sung-Min
Jeon, In-Cheol
Hong, Ki-Hoon
author_facet Jeong, Byoung-Lock
Ha, Sung-Min
Jeon, In-Cheol
Hong, Ki-Hoon
author_sort Jeong, Byoung-Lock
collection PubMed
description [Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 years) were recruited via convenience sampling of university students. [Methods] Real-time US measurements of the CSA and MT of the longus colli were recorded. Repeated US measurements using a standard protocol were performed on the same day 1 hour apart to assess intra- and inter-rater reliability. Intra-class correlation coefficients (ICC; 2, 1) were used to determine the intra- and inter-rater reliability of the CSA and MT measurements. [Results] This study demonstrated that the US measurements (0.5 and 1 kg) of the CSA and MT of the longus colli give reliable and consistent results. [Conclusion] Based on these results, a consistent inward pressure of the probe is needed to ensure precise US measurement of the longus colli muscle.
format Online
Article
Text
id pubmed-4681948
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-46819482015-12-22 Reliability of ultrasonography measurement for the longus colli according to inward probe pressure Jeong, Byoung-Lock Ha, Sung-Min Jeon, In-Cheol Hong, Ki-Hoon J Phys Ther Sci Original Article [Purpose] To investigate the intra- and inter-rater reliability of the cross-sectional area (CSA) and muscle thickness (MT) of the longus colli according to the inward pressure of an ultrasonography (US) probe (0.5 and 1 kg). [Subjects] Thirteen subjects (11 males and 2 females; age, 23.1 ± 2.9 years) were recruited via convenience sampling of university students. [Methods] Real-time US measurements of the CSA and MT of the longus colli were recorded. Repeated US measurements using a standard protocol were performed on the same day 1 hour apart to assess intra- and inter-rater reliability. Intra-class correlation coefficients (ICC; 2, 1) were used to determine the intra- and inter-rater reliability of the CSA and MT measurements. [Results] This study demonstrated that the US measurements (0.5 and 1 kg) of the CSA and MT of the longus colli give reliable and consistent results. [Conclusion] Based on these results, a consistent inward pressure of the probe is needed to ensure precise US measurement of the longus colli muscle. The Society of Physical Therapy Science 2015-11-30 2015-11 /pmc/articles/PMC4681948/ /pubmed/26696741 http://dx.doi.org/10.1589/jpts.27.3579 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Original Article
Jeong, Byoung-Lock
Ha, Sung-Min
Jeon, In-Cheol
Hong, Ki-Hoon
Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
title Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
title_full Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
title_fullStr Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
title_full_unstemmed Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
title_short Reliability of ultrasonography measurement for the longus colli according to inward probe pressure
title_sort reliability of ultrasonography measurement for the longus colli according to inward probe pressure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681948/
https://www.ncbi.nlm.nih.gov/pubmed/26696741
http://dx.doi.org/10.1589/jpts.27.3579
work_keys_str_mv AT jeongbyounglock reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure
AT hasungmin reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure
AT jeonincheol reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure
AT hongkihoon reliabilityofultrasonographymeasurementforthelonguscolliaccordingtoinwardprobepressure