Cargando…

Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force

BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite eleme...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Ying-juan, Chang, Shao-hai, Ye, Jian-tao, Ye, Yu-shan, Yu, Yan-song
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4682797/
https://www.ncbi.nlm.nih.gov/pubmed/26659581
http://dx.doi.org/10.1371/journal.pone.0144744
_version_ 1782405924460167168
author Lu, Ying-juan
Chang, Shao-hai
Ye, Jian-tao
Ye, Yu-shan
Yu, Yan-song
author_facet Lu, Ying-juan
Chang, Shao-hai
Ye, Jian-tao
Ye, Yu-shan
Yu, Yan-song
author_sort Lu, Ying-juan
collection PubMed
description BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. RESULTS: The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. CONCLUSION: When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm.
format Online
Article
Text
id pubmed-4682797
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46827972015-12-31 Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force Lu, Ying-juan Chang, Shao-hai Ye, Jian-tao Ye, Yu-shan Yu, Yan-song PLoS One Research Article BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. RESULTS: The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. CONCLUSION: When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm. Public Library of Science 2015-12-14 /pmc/articles/PMC4682797/ /pubmed/26659581 http://dx.doi.org/10.1371/journal.pone.0144744 Text en © 2015 Lu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lu, Ying-juan
Chang, Shao-hai
Ye, Jian-tao
Ye, Yu-shan
Yu, Yan-song
Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
title Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
title_full Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
title_fullStr Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
title_full_unstemmed Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
title_short Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
title_sort finite element analysis of bone stress around micro-implants of different diameters and lengths with application of a single or composite torque force
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4682797/
https://www.ncbi.nlm.nih.gov/pubmed/26659581
http://dx.doi.org/10.1371/journal.pone.0144744
work_keys_str_mv AT luyingjuan finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce
AT changshaohai finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce
AT yejiantao finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce
AT yeyushan finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce
AT yuyansong finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce