Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force
BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite eleme...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4682797/ https://www.ncbi.nlm.nih.gov/pubmed/26659581 http://dx.doi.org/10.1371/journal.pone.0144744 |
_version_ | 1782405924460167168 |
---|---|
author | Lu, Ying-juan Chang, Shao-hai Ye, Jian-tao Ye, Yu-shan Yu, Yan-song |
author_facet | Lu, Ying-juan Chang, Shao-hai Ye, Jian-tao Ye, Yu-shan Yu, Yan-song |
author_sort | Lu, Ying-juan |
collection | PubMed |
description | BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. RESULTS: The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. CONCLUSION: When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm. |
format | Online Article Text |
id | pubmed-4682797 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-46827972015-12-31 Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force Lu, Ying-juan Chang, Shao-hai Ye, Jian-tao Ye, Yu-shan Yu, Yan-song PLoS One Research Article BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. RESULTS: The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. CONCLUSION: When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm. Public Library of Science 2015-12-14 /pmc/articles/PMC4682797/ /pubmed/26659581 http://dx.doi.org/10.1371/journal.pone.0144744 Text en © 2015 Lu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Lu, Ying-juan Chang, Shao-hai Ye, Jian-tao Ye, Yu-shan Yu, Yan-song Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force |
title | Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force |
title_full | Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force |
title_fullStr | Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force |
title_full_unstemmed | Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force |
title_short | Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force |
title_sort | finite element analysis of bone stress around micro-implants of different diameters and lengths with application of a single or composite torque force |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4682797/ https://www.ncbi.nlm.nih.gov/pubmed/26659581 http://dx.doi.org/10.1371/journal.pone.0144744 |
work_keys_str_mv | AT luyingjuan finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce AT changshaohai finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce AT yejiantao finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce AT yeyushan finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce AT yuyansong finiteelementanalysisofbonestressaroundmicroimplantsofdifferentdiametersandlengthswithapplicationofasingleorcompositetorqueforce |