Cargando…

Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph

PURPOSE: To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT). METHODS: Fifty-three healthy eyes of 28 subjects unde...

Descripción completa

Detalles Bibliográficos
Autores principales: Kita, Yoshiyuki, Hollό, Gábor, Kita, Ritsuko, Horie, Daisuke, Inoue, Makoto, Hirakata, Akito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4682851/
https://www.ncbi.nlm.nih.gov/pubmed/26657805
http://dx.doi.org/10.1371/journal.pone.0144721
_version_ 1782405935334948864
author Kita, Yoshiyuki
Hollό, Gábor
Kita, Ritsuko
Horie, Daisuke
Inoue, Makoto
Hirakata, Akito
author_facet Kita, Yoshiyuki
Hollό, Gábor
Kita, Ritsuko
Horie, Daisuke
Inoue, Makoto
Hirakata, Akito
author_sort Kita, Yoshiyuki
collection PubMed
description PURPOSE: To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT). METHODS: Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter. RESULTS: The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively. CONCLUSIONS: Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters.
format Online
Article
Text
id pubmed-4682851
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-46828512015-12-31 Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph Kita, Yoshiyuki Hollό, Gábor Kita, Ritsuko Horie, Daisuke Inoue, Makoto Hirakata, Akito PLoS One Research Article PURPOSE: To evaluate the intrasession reproducibility of various thickness parameters used to diagnose and follow-up glaucoma, in particular circumpapillary total retinal thickness (cpTR) provided by the RS-3000 optical coherence tomograph (OCT). METHODS: Fifty-three healthy eyes of 28 subjects underwent three consecutive imaging with the RS-3000 Advance OCT (NIDEK, Aichi,Japan) to evaluate the intrasession reproducibility of circumpapillary total retinal thickness (cpTR), circumpapillary retinal nerve fiber layer thickness (cpRNFL), macular ganglion cell complex thickness (mGCC) and macular total retina thickness (mTR) measurements. Intraclass correlation (ICC), coefficient of variation (CV) and reproducibility coefficient (RC) were calculated for each parameter. RESULTS: The ICC and CV values for mean cpTR and cpRNFL were 0.987 and 0.897, and 0.60% and 2.81%, respectively. The RC values for the mean cpTR and cpRNFL were 5.95 μm and 9.04 μm, respectively. For all cpTR parameters the ICC values were higher and both the CV and RC values were lower than those for the corresponding cpRNFL parameters. The ICC and CV values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 0.983, 0.980, 0.983 and 0.988, and 0.84%, 0.98%, 0.48% and 0.43%, respectively. The RC values for superior mGCC, inferior mGCC, superior mTR and inferior mTR were 2.86 μm, 3.12 μm, 4.41μm and 4.43 μm, respectively. CONCLUSIONS: Intrasession reproducibility of cpTR, mGCC and mTR measurements made on healthy eyes was high. Repeatability of cpTR measurements was better than that of the corresponding cpRNFL measurements. These results suggest that future clinical investigations addressing detection of glaucoma and glaucomatous progression with the RS-3000 OCT may benefit from focusing on the cpTR parameters. Public Library of Science 2015-12-14 /pmc/articles/PMC4682851/ /pubmed/26657805 http://dx.doi.org/10.1371/journal.pone.0144721 Text en © 2015 Kita et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Kita, Yoshiyuki
Hollό, Gábor
Kita, Ritsuko
Horie, Daisuke
Inoue, Makoto
Hirakata, Akito
Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph
title Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph
title_full Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph
title_fullStr Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph
title_full_unstemmed Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph
title_short Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph
title_sort differences of intrasession reproducibility of circumpapillary total retinal thickness and circumpapillary retinal nerve fiber layer thickness measurements made with the rs-3000 optical coherence tomograph
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4682851/
https://www.ncbi.nlm.nih.gov/pubmed/26657805
http://dx.doi.org/10.1371/journal.pone.0144721
work_keys_str_mv AT kitayoshiyuki differencesofintrasessionreproducibilityofcircumpapillarytotalretinalthicknessandcircumpapillaryretinalnervefiberlayerthicknessmeasurementsmadewiththers3000opticalcoherencetomograph
AT hollogabor differencesofintrasessionreproducibilityofcircumpapillarytotalretinalthicknessandcircumpapillaryretinalnervefiberlayerthicknessmeasurementsmadewiththers3000opticalcoherencetomograph
AT kitaritsuko differencesofintrasessionreproducibilityofcircumpapillarytotalretinalthicknessandcircumpapillaryretinalnervefiberlayerthicknessmeasurementsmadewiththers3000opticalcoherencetomograph
AT horiedaisuke differencesofintrasessionreproducibilityofcircumpapillarytotalretinalthicknessandcircumpapillaryretinalnervefiberlayerthicknessmeasurementsmadewiththers3000opticalcoherencetomograph
AT inouemakoto differencesofintrasessionreproducibilityofcircumpapillarytotalretinalthicknessandcircumpapillaryretinalnervefiberlayerthicknessmeasurementsmadewiththers3000opticalcoherencetomograph
AT hirakataakito differencesofintrasessionreproducibilityofcircumpapillarytotalretinalthicknessandcircumpapillaryretinalnervefiberlayerthicknessmeasurementsmadewiththers3000opticalcoherencetomograph