Cargando…
Development of a device for detecting target specimens from EUS-guided FNA samples
Background and study aims: Specimens collected by fine needle are microscopic and contain blood; therefore, the presence of a target specimen within a sample is often difficult to confirm. Although rapid on-site evaluation (ROSE) during endoscopic ultrasound-guided fine needle aspiration biopsy (EUS...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683133/ https://www.ncbi.nlm.nih.gov/pubmed/26716133 http://dx.doi.org/10.1055/s-0034-1393076 |
_version_ | 1782405979751579648 |
---|---|
author | Matsumoto, Kazuya Ueki, Masaru Takeda, Yohei Harada, Kenichi Onoyama, Takumi Kawata, Soichiro Ikebuchi, Yuichiro Imamoto, Ryu Horie, Yasushi Murawaki, Yoshikazu |
author_facet | Matsumoto, Kazuya Ueki, Masaru Takeda, Yohei Harada, Kenichi Onoyama, Takumi Kawata, Soichiro Ikebuchi, Yuichiro Imamoto, Ryu Horie, Yasushi Murawaki, Yoshikazu |
author_sort | Matsumoto, Kazuya |
collection | PubMed |
description | Background and study aims: Specimens collected by fine needle are microscopic and contain blood; therefore, the presence of a target specimen within a sample is often difficult to confirm. Although rapid on-site evaluation (ROSE) during endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNA) is beneficial, many health care facilities are unable to apply this technique due to a lack of cytopathologists. The aim of this study was to develop and validate a device that detects the target specimen within pancreatic tumor EUS-FNA samples. Patients and methods: Fifty-eight consecutive patients with solid pancreatic masses were studied for a preliminary case series at a tertiary-care university hospital (Tottori University Hospital, Yonago, Japan). The material collected was checked with a target sample check illuminator (TSCI) and was evaluated by one cytopathologist. Results: The agreement rate between the TSCI and histopathology was 93.7 %. Further testing procedures were not needed in 91.4 % of patients, and the mean number of needle punctures was 1.2 after a single pass using TSCI. No adverse events were encountered with the procedure. Conclusions: With the introduction of the TSCI in EUS-FNA, it became possible to both collect the minimum necessary target samples by EUS-FNA and to end further procedures, even without performing ROSE. |
format | Online Article Text |
id | pubmed-4683133 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-46831332015-12-29 Development of a device for detecting target specimens from EUS-guided FNA samples Matsumoto, Kazuya Ueki, Masaru Takeda, Yohei Harada, Kenichi Onoyama, Takumi Kawata, Soichiro Ikebuchi, Yuichiro Imamoto, Ryu Horie, Yasushi Murawaki, Yoshikazu Endosc Int Open Article Background and study aims: Specimens collected by fine needle are microscopic and contain blood; therefore, the presence of a target specimen within a sample is often difficult to confirm. Although rapid on-site evaluation (ROSE) during endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNA) is beneficial, many health care facilities are unable to apply this technique due to a lack of cytopathologists. The aim of this study was to develop and validate a device that detects the target specimen within pancreatic tumor EUS-FNA samples. Patients and methods: Fifty-eight consecutive patients with solid pancreatic masses were studied for a preliminary case series at a tertiary-care university hospital (Tottori University Hospital, Yonago, Japan). The material collected was checked with a target sample check illuminator (TSCI) and was evaluated by one cytopathologist. Results: The agreement rate between the TSCI and histopathology was 93.7 %. Further testing procedures were not needed in 91.4 % of patients, and the mean number of needle punctures was 1.2 after a single pass using TSCI. No adverse events were encountered with the procedure. Conclusions: With the introduction of the TSCI in EUS-FNA, it became possible to both collect the minimum necessary target samples by EUS-FNA and to end further procedures, even without performing ROSE. © Georg Thieme Verlag KG 2015-12 2015-09-23 /pmc/articles/PMC4683133/ /pubmed/26716133 http://dx.doi.org/10.1055/s-0034-1393076 Text en © Thieme Medical Publishers |
spellingShingle | Article Matsumoto, Kazuya Ueki, Masaru Takeda, Yohei Harada, Kenichi Onoyama, Takumi Kawata, Soichiro Ikebuchi, Yuichiro Imamoto, Ryu Horie, Yasushi Murawaki, Yoshikazu Development of a device for detecting target specimens from EUS-guided FNA samples |
title | Development of a device for detecting target specimens from EUS-guided FNA samples |
title_full | Development of a device for detecting target specimens from EUS-guided FNA samples |
title_fullStr | Development of a device for detecting target specimens from EUS-guided FNA samples |
title_full_unstemmed | Development of a device for detecting target specimens from EUS-guided FNA samples |
title_short | Development of a device for detecting target specimens from EUS-guided FNA samples |
title_sort | development of a device for detecting target specimens from eus-guided fna samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683133/ https://www.ncbi.nlm.nih.gov/pubmed/26716133 http://dx.doi.org/10.1055/s-0034-1393076 |
work_keys_str_mv | AT matsumotokazuya developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT uekimasaru developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT takedayohei developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT haradakenichi developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT onoyamatakumi developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT kawatasoichiro developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT ikebuchiyuichiro developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT imamotoryu developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT horieyasushi developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples AT murawakiyoshikazu developmentofadevicefordetectingtargetspecimensfromeusguidedfnasamples |