Cargando…

Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry

Aim: To assess the frequency of glaucoma-like alterations in Alzheimer's disease (AD) patients using Heidelberg Retinal Tomograph III (HRT-3) and Frequency Doubling Technology (FDT) perimetry. Methods: The study included 51 eyes of 51 AD subjects and 67 eyes of 67 age- and sex-matched controls....

Descripción completa

Detalles Bibliográficos
Autores principales: Cesareo, Massimo, Martucci, Alessio, Ciuffoletti, Elena, Mancino, Raffaele, Cerulli, Angelica, Sorge, Roberto P., Martorana, Alessandro, Sancesario, Giuseppe, Nucci, Carlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683203/
https://www.ncbi.nlm.nih.gov/pubmed/26733792
http://dx.doi.org/10.3389/fnins.2015.00479
_version_ 1782405994087710720
author Cesareo, Massimo
Martucci, Alessio
Ciuffoletti, Elena
Mancino, Raffaele
Cerulli, Angelica
Sorge, Roberto P.
Martorana, Alessandro
Sancesario, Giuseppe
Nucci, Carlo
author_facet Cesareo, Massimo
Martucci, Alessio
Ciuffoletti, Elena
Mancino, Raffaele
Cerulli, Angelica
Sorge, Roberto P.
Martorana, Alessandro
Sancesario, Giuseppe
Nucci, Carlo
author_sort Cesareo, Massimo
collection PubMed
description Aim: To assess the frequency of glaucoma-like alterations in Alzheimer's disease (AD) patients using Heidelberg Retinal Tomograph III (HRT-3) and Frequency Doubling Technology (FDT) perimetry. Methods: The study included 51 eyes of 51 AD subjects and 67 eyes of 67 age- and sex-matched controls. Subjects underwent an ophthalmological examination including measurements of intraocular pressure (IOP), Matrix FDT visual field testing, optic nerve head morphology and retinal nerve fiber layer thickness (RNFLt) assessment by slit-lamp biomicroscopy and HRT-3. Results: The frequency of alterations was significantly higher in the AD group (27.5 vs. 7.5%; p = 0.003; OR = 4.69). AD patients showed lower IOP (p = 0.000) despite not significantly different values of central corneal thickness (CCT) between the groups (p = 0.336). Of all the stereometric parameters measured by HRT-3, RNFLt was significantly lower in AD patients (p = 0.013). This group also had significantly worse results in terms of Moorfields Regression Analysis (p = 0.027). Matrix showed significantly worse Mean Deviation (MD) (p = 0.000) and Pattern Standard Deviation (PSD) (p = 0.000) values and more altered Glaucoma Hemifield Test (p = 0.006) in AD patients. Pearson's R correlation test showed that Mini Mental State Examination is directly correlated with MD (R = 0.349; p = 0.034) and inversely correlated with PSD (R = −0.357; p = 0.030). Conclusion: Patients with AD have a higher frequency of glaucoma-like alterations, as detected by the use of HRT-3. These alterations were not associated with elevated IOP or abnormal CCT values.
format Online
Article
Text
id pubmed-4683203
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-46832032016-01-05 Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry Cesareo, Massimo Martucci, Alessio Ciuffoletti, Elena Mancino, Raffaele Cerulli, Angelica Sorge, Roberto P. Martorana, Alessandro Sancesario, Giuseppe Nucci, Carlo Front Neurosci Psychiatry Aim: To assess the frequency of glaucoma-like alterations in Alzheimer's disease (AD) patients using Heidelberg Retinal Tomograph III (HRT-3) and Frequency Doubling Technology (FDT) perimetry. Methods: The study included 51 eyes of 51 AD subjects and 67 eyes of 67 age- and sex-matched controls. Subjects underwent an ophthalmological examination including measurements of intraocular pressure (IOP), Matrix FDT visual field testing, optic nerve head morphology and retinal nerve fiber layer thickness (RNFLt) assessment by slit-lamp biomicroscopy and HRT-3. Results: The frequency of alterations was significantly higher in the AD group (27.5 vs. 7.5%; p = 0.003; OR = 4.69). AD patients showed lower IOP (p = 0.000) despite not significantly different values of central corneal thickness (CCT) between the groups (p = 0.336). Of all the stereometric parameters measured by HRT-3, RNFLt was significantly lower in AD patients (p = 0.013). This group also had significantly worse results in terms of Moorfields Regression Analysis (p = 0.027). Matrix showed significantly worse Mean Deviation (MD) (p = 0.000) and Pattern Standard Deviation (PSD) (p = 0.000) values and more altered Glaucoma Hemifield Test (p = 0.006) in AD patients. Pearson's R correlation test showed that Mini Mental State Examination is directly correlated with MD (R = 0.349; p = 0.034) and inversely correlated with PSD (R = −0.357; p = 0.030). Conclusion: Patients with AD have a higher frequency of glaucoma-like alterations, as detected by the use of HRT-3. These alterations were not associated with elevated IOP or abnormal CCT values. Frontiers Media S.A. 2015-12-18 /pmc/articles/PMC4683203/ /pubmed/26733792 http://dx.doi.org/10.3389/fnins.2015.00479 Text en Copyright © 2015 Cesareo, Martucci, Ciuffoletti, Mancino, Cerulli, Sorge, Martorana, Sancesario and Nucci. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Psychiatry
Cesareo, Massimo
Martucci, Alessio
Ciuffoletti, Elena
Mancino, Raffaele
Cerulli, Angelica
Sorge, Roberto P.
Martorana, Alessandro
Sancesario, Giuseppe
Nucci, Carlo
Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
title Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
title_full Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
title_fullStr Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
title_full_unstemmed Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
title_short Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry
title_sort association between alzheimer's disease and glaucoma: a study based on heidelberg retinal tomography and frequency doubling technology perimetry
topic Psychiatry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683203/
https://www.ncbi.nlm.nih.gov/pubmed/26733792
http://dx.doi.org/10.3389/fnins.2015.00479
work_keys_str_mv AT cesareomassimo associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT martuccialessio associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT ciuffolettielena associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT mancinoraffaele associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT cerulliangelica associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT sorgerobertop associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT martoranaalessandro associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT sancesariogiuseppe associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry
AT nuccicarlo associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry