Aim: To assess the frequency of glaucoma-like alterations in Alzheimer's disease (AD) patients using Heidelberg Retinal Tomograph III (HRT-3) and Frequency Doubling Technology (FDT) perimetry. Methods: The study included 51 eyes of 51 AD subjects and 67 eyes of 67 age- and sex-matched controls....
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683203/ https://www.ncbi.nlm.nih.gov/pubmed/26733792 http://dx.doi.org/10.3389/fnins.2015.00479 |
_version_ | 1782405994087710720 |
---|---|
author | Cesareo, Massimo Martucci, Alessio Ciuffoletti, Elena Mancino, Raffaele Cerulli, Angelica Sorge, Roberto P. Martorana, Alessandro Sancesario, Giuseppe Nucci, Carlo |
author_facet | Cesareo, Massimo Martucci, Alessio Ciuffoletti, Elena Mancino, Raffaele Cerulli, Angelica Sorge, Roberto P. Martorana, Alessandro Sancesario, Giuseppe Nucci, Carlo |
author_sort | Cesareo, Massimo |
collection | PubMed |
description | Aim: To assess the frequency of glaucoma-like alterations in Alzheimer's disease (AD) patients using Heidelberg Retinal Tomograph III (HRT-3) and Frequency Doubling Technology (FDT) perimetry. Methods: The study included 51 eyes of 51 AD subjects and 67 eyes of 67 age- and sex-matched controls. Subjects underwent an ophthalmological examination including measurements of intraocular pressure (IOP), Matrix FDT visual field testing, optic nerve head morphology and retinal nerve fiber layer thickness (RNFLt) assessment by slit-lamp biomicroscopy and HRT-3. Results: The frequency of alterations was significantly higher in the AD group (27.5 vs. 7.5%; p = 0.003; OR = 4.69). AD patients showed lower IOP (p = 0.000) despite not significantly different values of central corneal thickness (CCT) between the groups (p = 0.336). Of all the stereometric parameters measured by HRT-3, RNFLt was significantly lower in AD patients (p = 0.013). This group also had significantly worse results in terms of Moorfields Regression Analysis (p = 0.027). Matrix showed significantly worse Mean Deviation (MD) (p = 0.000) and Pattern Standard Deviation (PSD) (p = 0.000) values and more altered Glaucoma Hemifield Test (p = 0.006) in AD patients. Pearson's R correlation test showed that Mini Mental State Examination is directly correlated with MD (R = 0.349; p = 0.034) and inversely correlated with PSD (R = −0.357; p = 0.030). Conclusion: Patients with AD have a higher frequency of glaucoma-like alterations, as detected by the use of HRT-3. These alterations were not associated with elevated IOP or abnormal CCT values. |
format | Online Article Text |
id | pubmed-4683203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-46832032016-01-05 Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry Cesareo, Massimo Martucci, Alessio Ciuffoletti, Elena Mancino, Raffaele Cerulli, Angelica Sorge, Roberto P. Martorana, Alessandro Sancesario, Giuseppe Nucci, Carlo Front Neurosci Psychiatry Aim: To assess the frequency of glaucoma-like alterations in Alzheimer's disease (AD) patients using Heidelberg Retinal Tomograph III (HRT-3) and Frequency Doubling Technology (FDT) perimetry. Methods: The study included 51 eyes of 51 AD subjects and 67 eyes of 67 age- and sex-matched controls. Subjects underwent an ophthalmological examination including measurements of intraocular pressure (IOP), Matrix FDT visual field testing, optic nerve head morphology and retinal nerve fiber layer thickness (RNFLt) assessment by slit-lamp biomicroscopy and HRT-3. Results: The frequency of alterations was significantly higher in the AD group (27.5 vs. 7.5%; p = 0.003; OR = 4.69). AD patients showed lower IOP (p = 0.000) despite not significantly different values of central corneal thickness (CCT) between the groups (p = 0.336). Of all the stereometric parameters measured by HRT-3, RNFLt was significantly lower in AD patients (p = 0.013). This group also had significantly worse results in terms of Moorfields Regression Analysis (p = 0.027). Matrix showed significantly worse Mean Deviation (MD) (p = 0.000) and Pattern Standard Deviation (PSD) (p = 0.000) values and more altered Glaucoma Hemifield Test (p = 0.006) in AD patients. Pearson's R correlation test showed that Mini Mental State Examination is directly correlated with MD (R = 0.349; p = 0.034) and inversely correlated with PSD (R = −0.357; p = 0.030). Conclusion: Patients with AD have a higher frequency of glaucoma-like alterations, as detected by the use of HRT-3. These alterations were not associated with elevated IOP or abnormal CCT values. Frontiers Media S.A. 2015-12-18 /pmc/articles/PMC4683203/ /pubmed/26733792 http://dx.doi.org/10.3389/fnins.2015.00479 Text en Copyright © 2015 Cesareo, Martucci, Ciuffoletti, Mancino, Cerulli, Sorge, Martorana, Sancesario and Nucci. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Psychiatry Cesareo, Massimo Martucci, Alessio Ciuffoletti, Elena Mancino, Raffaele Cerulli, Angelica Sorge, Roberto P. Martorana, Alessandro Sancesario, Giuseppe Nucci, Carlo Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry |
title | Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry |
title_full | Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry |
title_fullStr | Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry |
title_full_unstemmed | Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry |
title_short | Association Between Alzheimer's Disease and Glaucoma: A Study Based on Heidelberg Retinal Tomography and Frequency Doubling Technology Perimetry |
title_sort | association between alzheimer's disease and glaucoma: a study based on heidelberg retinal tomography and frequency doubling technology perimetry |
topic | Psychiatry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683203/ https://www.ncbi.nlm.nih.gov/pubmed/26733792 http://dx.doi.org/10.3389/fnins.2015.00479 |
work_keys_str_mv | AT cesareomassimo associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT martuccialessio associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT ciuffolettielena associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT mancinoraffaele associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT cerulliangelica associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT sorgerobertop associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT martoranaalessandro associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT sancesariogiuseppe associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry AT nuccicarlo associationbetweenalzheimersdiseaseandglaucomaastudybasedonheidelbergretinaltomographyandfrequencydoublingtechnologyperimetry |