Cargando…

Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement

We present an unusual case of life-threatening hemothorax in a 15-year-old boy following subclavian vein tear during internal jugular vein (IJV) cannulation prior to initiation of surgery (mitral valve replacement). Successful IJV cannulation was done in the third attempt. However, we missed the sub...

Descripción completa

Detalles Bibliográficos
Autores principales: Mishra, Sandeep Kumar, Paulose, Deepak, Kundra, Pankaj, Parida, Satyen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683488/
https://www.ncbi.nlm.nih.gov/pubmed/26712992
http://dx.doi.org/10.4103/0259-1162.161815
_version_ 1782406033188061184
author Mishra, Sandeep Kumar
Paulose, Deepak
Kundra, Pankaj
Parida, Satyen
author_facet Mishra, Sandeep Kumar
Paulose, Deepak
Kundra, Pankaj
Parida, Satyen
author_sort Mishra, Sandeep Kumar
collection PubMed
description We present an unusual case of life-threatening hemothorax in a 15-year-old boy following subclavian vein tear during internal jugular vein (IJV) cannulation prior to initiation of surgery (mitral valve replacement). Successful IJV cannulation was done in the third attempt. However, we missed the subclavian tear which occurred during the first two initial attempts as there was no clinical evidence suggestive of it at that point of time. This undiagnosed hemothorax led to hemodynamic decompensation requiring high volume and inotropic support to wean the patient off cardiopulmonary bypass. This unusually high requirement of fluid and inotropes required the surgeon to look for noncardiac causes for the hemodynamic disturbance and he noticed a bulge in the right pleura, which on exploration had approximately 1.5 L of collected blood. It was then retrospectively analyzed that the cause of this hemothorax could have been the undue lateral orientation of the needle during IJV cannulation and the advancement of the dilator to its entire length could have injured the subclavian vein. Here, we also would like to discuss the safety precautions to be taken during the cannulation, like the needle orientation and the length to which the dilator must be advanced for safe central venous cannulation.
format Online
Article
Text
id pubmed-4683488
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-46834882015-12-28 Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement Mishra, Sandeep Kumar Paulose, Deepak Kundra, Pankaj Parida, Satyen Anesth Essays Res Case Report We present an unusual case of life-threatening hemothorax in a 15-year-old boy following subclavian vein tear during internal jugular vein (IJV) cannulation prior to initiation of surgery (mitral valve replacement). Successful IJV cannulation was done in the third attempt. However, we missed the subclavian tear which occurred during the first two initial attempts as there was no clinical evidence suggestive of it at that point of time. This undiagnosed hemothorax led to hemodynamic decompensation requiring high volume and inotropic support to wean the patient off cardiopulmonary bypass. This unusually high requirement of fluid and inotropes required the surgeon to look for noncardiac causes for the hemodynamic disturbance and he noticed a bulge in the right pleura, which on exploration had approximately 1.5 L of collected blood. It was then retrospectively analyzed that the cause of this hemothorax could have been the undue lateral orientation of the needle during IJV cannulation and the advancement of the dilator to its entire length could have injured the subclavian vein. Here, we also would like to discuss the safety precautions to be taken during the cannulation, like the needle orientation and the length to which the dilator must be advanced for safe central venous cannulation. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4683488/ /pubmed/26712992 http://dx.doi.org/10.4103/0259-1162.161815 Text en Copyright: © 2015 Anesthesia: Essays and Researches http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Case Report
Mishra, Sandeep Kumar
Paulose, Deepak
Kundra, Pankaj
Parida, Satyen
Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
title Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
title_full Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
title_fullStr Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
title_full_unstemmed Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
title_short Massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
title_sort massive hemothorax due to subclavian vein tear during internal jugular vein cannulation in a 15-year-old boy scheduled for mitral valve replacement
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683488/
https://www.ncbi.nlm.nih.gov/pubmed/26712992
http://dx.doi.org/10.4103/0259-1162.161815
work_keys_str_mv AT mishrasandeepkumar massivehemothoraxduetosubclavianveintearduringinternaljugularveincannulationina15yearoldboyscheduledformitralvalvereplacement
AT paulosedeepak massivehemothoraxduetosubclavianveintearduringinternaljugularveincannulationina15yearoldboyscheduledformitralvalvereplacement
AT kundrapankaj massivehemothoraxduetosubclavianveintearduringinternaljugularveincannulationina15yearoldboyscheduledformitralvalvereplacement
AT paridasatyen massivehemothoraxduetosubclavianveintearduringinternaljugularveincannulationina15yearoldboyscheduledformitralvalvereplacement