Cargando…

The effect of micro-electric current and other activation techniques on dissolution abilities of sodium hypochlorite in bovine tissues

BACKGROUND: The aim of the study was to evaluate the effects of micro-electric current on sodium hypochlorite’s (NaOCl’s) tissue-dissolution abilities, compared with other activation methods, including sonic, ultrasonic, pipetting, and temperature. METHODS: Bovine muscle tissues (n = 154) with stand...

Descripción completa

Detalles Bibliográficos
Autores principales: Ertuğrul, İhsan Furkan, Maden, Murat, Orhan, Ekim Onur, Özkorucuklu, Sabriye Perçin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4683763/
https://www.ncbi.nlm.nih.gov/pubmed/26681346
http://dx.doi.org/10.1186/s12903-015-0152-1
Descripción
Sumario:BACKGROUND: The aim of the study was to evaluate the effects of micro-electric current on sodium hypochlorite’s (NaOCl’s) tissue-dissolution abilities, compared with other activation methods, including sonic, ultrasonic, pipetting, and temperature. METHODS: Bovine muscle tissues (n = 154) with standard sizes and weights were prepared and divided into two temperature groups: room temperature and 45 °C. Each temperature group was divided into seven sub-groups by activation methods: D = distilled water (−control); NaOCl = 5.25 % passive NaOCl (+ control); P = 5.25 % NaOCl with pipetting; SA = 5.25 % NaOCl with sonic activation; UA = 5.25 % NaOCl with ultrasonic activation; E-NaOCl = 5.25 % NaOCl with micro-electric current; and E-NaOCl + P = 5.25 % NaOCl with micro-electric current and pipetting. Specimens were weighed before and after treatment. Average, standard deviation, minimum, maximum, and median were calculated for each group. Resulting data were analyzed statistically using multi-way ANOVA and Tukey HSD tests. The level of the alpha-type error was set at < 0.05. RESULTS: At room temperature, the E-NaOCl + P group dissolved the highest amount of tissue (p < 0.05), and the UA, SA, and P groups dissolved significantly higher amounts of tissue than did the positive control or E-NaOCl groups (p < 0.05). At 45 °C, there was no significant difference between the SA and E-NaOCl groups (p > 0.05), and the E-NaOCl + P group dissolved a higher amount of tissue than any other group (p < 0.05). CONCLUSIONS: Using NaOCl with micro-electric current can improve the tissue-dissolving ability of the solution. In addition, this method can be combined with additional techniques, such as heating and/or pipetting, to achieve a synergistic effect of NaOCl on tissue dissolution.