Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma

BACKGROUND: Poisoning is one of the most common medical presentations in a hospital. Hypoglycemic patients are at increased risk of toxicity. The purpose of this study was to compare capillary blood glucose and venous blood glucose measurements using glucometer against laboratory blood glucose in ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Yaraghi, Ahmad, Mood, Nastaran Eizadi, Dolatabadi, Leila Kamali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4685638/
https://www.ncbi.nlm.nih.gov/pubmed/26693472
http://dx.doi.org/10.4103/2277-9175.170242
_version_ 1782406343348453376
author Yaraghi, Ahmad
Mood, Nastaran Eizadi
Dolatabadi, Leila Kamali
author_facet Yaraghi, Ahmad
Mood, Nastaran Eizadi
Dolatabadi, Leila Kamali
author_sort Yaraghi, Ahmad
collection PubMed
description BACKGROUND: Poisoning is one of the most common medical presentations in a hospital. Hypoglycemic patients are at increased risk of toxicity. The purpose of this study was to compare capillary blood glucose and venous blood glucose measurements using glucometer against laboratory blood glucose in case of poisoned patients being in coma. MATERIALS AND METHODS: During the 6-month study period, a random sample of 98 patients was admitted in the Department of Poisoning Emergency and Clinical Toxicology of Noor Hospital, Isfahan University of Medical Sciences, Iran from May 2010. Data collected included age, gender, poisoning reason, vital signs, and Glasgow Coma Scale. Capillary blood samples were obtained from the fourth fingertip of the non-dominant hand. t-Test, paired t-test, Pearson's correlation analysis, and one-way analysis of variance (ANOVA) were used for analysis. RESULTS: The mean of capillary blood glucose was 115.7 ± 50.2, of venous blood glucose measured by glucose meter was 117.8 ± 47.3, and of glucose measured in vitro was 115.8 ± 55.1. Mean of blood glucose showed no significant difference with the three mentioned methods. The correlation between capillary and intravenous blood glucose samples measured by glucometer was 0.93, between capillary blood glucose and in vitro measured venous blood glucose was 0.78, and between venous blood glucose measured by glucose meter and in vitro measured sample was 0.81. The mean of capillary and venous blood glucose levels measured by glucose meter, capillary and venous blood glucose levels measured in vitro, and venous blood glucose levels measured by glucose meter had no significant differences. CONCLUSION: Using venous blood sample and measuring the glucose level in it by glucometer is an acceptable and advisable method, and capillary blood glucose measurement by using glucometer is not recommended for patients in coma.
format Online
Article
Text
id pubmed-4685638
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-46856382015-12-21 Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma Yaraghi, Ahmad Mood, Nastaran Eizadi Dolatabadi, Leila Kamali Adv Biomed Res Original Article BACKGROUND: Poisoning is one of the most common medical presentations in a hospital. Hypoglycemic patients are at increased risk of toxicity. The purpose of this study was to compare capillary blood glucose and venous blood glucose measurements using glucometer against laboratory blood glucose in case of poisoned patients being in coma. MATERIALS AND METHODS: During the 6-month study period, a random sample of 98 patients was admitted in the Department of Poisoning Emergency and Clinical Toxicology of Noor Hospital, Isfahan University of Medical Sciences, Iran from May 2010. Data collected included age, gender, poisoning reason, vital signs, and Glasgow Coma Scale. Capillary blood samples were obtained from the fourth fingertip of the non-dominant hand. t-Test, paired t-test, Pearson's correlation analysis, and one-way analysis of variance (ANOVA) were used for analysis. RESULTS: The mean of capillary blood glucose was 115.7 ± 50.2, of venous blood glucose measured by glucose meter was 117.8 ± 47.3, and of glucose measured in vitro was 115.8 ± 55.1. Mean of blood glucose showed no significant difference with the three mentioned methods. The correlation between capillary and intravenous blood glucose samples measured by glucometer was 0.93, between capillary blood glucose and in vitro measured venous blood glucose was 0.78, and between venous blood glucose measured by glucose meter and in vitro measured sample was 0.81. The mean of capillary and venous blood glucose levels measured by glucose meter, capillary and venous blood glucose levels measured in vitro, and venous blood glucose levels measured by glucose meter had no significant differences. CONCLUSION: Using venous blood sample and measuring the glucose level in it by glucometer is an acceptable and advisable method, and capillary blood glucose measurement by using glucometer is not recommended for patients in coma. Medknow Publications & Media Pvt Ltd 2015-11-23 /pmc/articles/PMC4685638/ /pubmed/26693472 http://dx.doi.org/10.4103/2277-9175.170242 Text en Copyright: © 2015 Yaraghi. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Yaraghi, Ahmad
Mood, Nastaran Eizadi
Dolatabadi, Leila Kamali
Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
title Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
title_full Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
title_fullStr Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
title_full_unstemmed Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
title_short Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
title_sort comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4685638/
https://www.ncbi.nlm.nih.gov/pubmed/26693472
http://dx.doi.org/10.4103/2277-9175.170242
work_keys_str_mv AT yaraghiahmad comparisonofcapillaryandvenousbloodglucoselevelsusingglucometerandlaboratorybloodglucoselevelinpoisonedpatientsbeingincoma
AT moodnastaraneizadi comparisonofcapillaryandvenousbloodglucoselevelsusingglucometerandlaboratorybloodglucoselevelinpoisonedpatientsbeingincoma
AT dolatabadileilakamali comparisonofcapillaryandvenousbloodglucoselevelsusingglucometerandlaboratorybloodglucoselevelinpoisonedpatientsbeingincoma