Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

OBJECTIVE(S): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and di...

Descripción completa

Detalles Bibliográficos
Autores principales: Fazeli-Bakhtiyari, Rana, Panahi-Azar, Vahid, Sorouraddin, Mohammad Hossein, Jouyban, Abolghasem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686582/
https://www.ncbi.nlm.nih.gov/pubmed/26730332
_version_ 1782406452679278592
author Fazeli-Bakhtiyari, Rana
Panahi-Azar, Vahid
Sorouraddin, Mohammad Hossein
Jouyban, Abolghasem
author_facet Fazeli-Bakhtiyari, Rana
Panahi-Azar, Vahid
Sorouraddin, Mohammad Hossein
Jouyban, Abolghasem
author_sort Fazeli-Bakhtiyari, Rana
collection PubMed
description OBJECTIVE(S): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. RESULTS: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. CONCLUSION: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma.
format Online
Article
Text
id pubmed-4686582
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Mashhad University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-46865822016-01-04 Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection Fazeli-Bakhtiyari, Rana Panahi-Azar, Vahid Sorouraddin, Mohammad Hossein Jouyban, Abolghasem Iran J Basic Med Sci Original Article OBJECTIVE(S): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. RESULTS: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. CONCLUSION: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma. Mashhad University of Medical Sciences 2015-10 /pmc/articles/PMC4686582/ /pubmed/26730332 Text en Copyright: © Iranian Journal of Basic Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Fazeli-Bakhtiyari, Rana
Panahi-Azar, Vahid
Sorouraddin, Mohammad Hossein
Jouyban, Abolghasem
Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
title Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
title_full Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
title_fullStr Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
title_full_unstemmed Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
title_short Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
title_sort determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686582/
https://www.ncbi.nlm.nih.gov/pubmed/26730332
work_keys_str_mv AT fazelibakhtiyarirana determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection
AT panahiazarvahid determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection
AT sorouraddinmohammadhossein determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection
AT jouybanabolghasem determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection