Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
OBJECTIVE(S): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and di...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mashhad University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686582/ https://www.ncbi.nlm.nih.gov/pubmed/26730332 |
_version_ | 1782406452679278592 |
---|---|
author | Fazeli-Bakhtiyari, Rana Panahi-Azar, Vahid Sorouraddin, Mohammad Hossein Jouyban, Abolghasem |
author_facet | Fazeli-Bakhtiyari, Rana Panahi-Azar, Vahid Sorouraddin, Mohammad Hossein Jouyban, Abolghasem |
author_sort | Fazeli-Bakhtiyari, Rana |
collection | PubMed |
description | OBJECTIVE(S): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. RESULTS: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. CONCLUSION: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma. |
format | Online Article Text |
id | pubmed-4686582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Mashhad University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-46865822016-01-04 Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection Fazeli-Bakhtiyari, Rana Panahi-Azar, Vahid Sorouraddin, Mohammad Hossein Jouyban, Abolghasem Iran J Basic Med Sci Original Article OBJECTIVE(S): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. RESULTS: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. CONCLUSION: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma. Mashhad University of Medical Sciences 2015-10 /pmc/articles/PMC4686582/ /pubmed/26730332 Text en Copyright: © Iranian Journal of Basic Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Fazeli-Bakhtiyari, Rana Panahi-Azar, Vahid Sorouraddin, Mohammad Hossein Jouyban, Abolghasem Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
title | Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
title_full | Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
title_fullStr | Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
title_full_unstemmed | Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
title_short | Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
title_sort | determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686582/ https://www.ncbi.nlm.nih.gov/pubmed/26730332 |
work_keys_str_mv | AT fazelibakhtiyarirana determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection AT panahiazarvahid determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection AT sorouraddinmohammadhossein determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection AT jouybanabolghasem determinationofvalproicacidinhumanplasmausingdispersiveliquidliquidmicroextractionfollowedbygaschromatographyflameionizationdetection |