Cargando…

The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study

Background: Breast implants are worldwide in use since 1962. Initially there were some problems with capsular contracture and the palpability of the rim of the implant. In 1968 this led to the introduction of the micropolyurethane foam-coating and then in 1970 to the first micropolyurethane foam-coa...

Descripción completa

Detalles Bibliográficos
Autor principal: Brunnert, Klaus E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: German Medical Science GMS Publishing House 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686800/
https://www.ncbi.nlm.nih.gov/pubmed/26713264
http://dx.doi.org/10.3205/iprs000079
_version_ 1782406500994514944
author Brunnert, Klaus E.
author_facet Brunnert, Klaus E.
author_sort Brunnert, Klaus E.
collection PubMed
description Background: Breast implants are worldwide in use since 1962. Initially there were some problems with capsular contracture and the palpability of the rim of the implant. In 1968 this led to the introduction of the micropolyurethane foam-coating and then in 1970 to the first micropolyurethane foam-coated implant by F.A. Ashley. As a result of additional technical refinements in manufacturing this new implant design significantly reduced complications i.e. capsular contracture and implant rotation. Methods: This study reports a single surgeon’s experience with aesthetic and reconstructive breast surgery, in primary and secondary cases with the sole use of micropolyurethane foam-coated Diagon/gel(®)4Two implants, partly in combination with the additional use of synthetic meshes, acellular dermal matrices and lipofilling. The trial is a prospective, single center cohort study designed to demonstrate the safety and effectiveness of the new implant design in primary and secondary aesthetic and reconstructive breast surgery. The reported data provide an interim report of the implantations performed from November 2010 to December 2013. Results: 90 patients were admitted to the study with 152 implants. The majority of the implants (n=95, 62.5%) were used in reoperative cases for either oncological (n=52, 34.2%) or aesthetic reasons (n=43, 28.3%). The median age of the study cohort was 45 years; the median body mass index was 21; the median observation time is 41 months. There was a very low complication rate, both short term within 6 weeks after the implantation of the silicone gel implant and in the follow up in November 2015. There were no serious complications needing explantation, no capsular fibrosis or implant rotation or rupture so far. There were only 4 minor complications (1.97%). There was 1 local recurrence 4 years after skin and nipple sparing mastectomy. Conclusion: The micropolyurethane foam-coated Diagon/gel(®)4Two implant is a very reliable silicone gel implant filled with two high cross-linked, cohesive and form stable gels. The study demonstrated a very high safety profile of the 4Two implant and its effectiveness in both primary and secondary reoperative aesthetic, oncological and reconstructive breast surgery. The study is ongoing, a longer follow-up will be needed to consolidate the data.
format Online
Article
Text
id pubmed-4686800
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher German Medical Science GMS Publishing House
record_format MEDLINE/PubMed
spelling pubmed-46868002015-12-28 The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study Brunnert, Klaus E. GMS Interdiscip Plast Reconstr Surg DGPW Article Background: Breast implants are worldwide in use since 1962. Initially there were some problems with capsular contracture and the palpability of the rim of the implant. In 1968 this led to the introduction of the micropolyurethane foam-coating and then in 1970 to the first micropolyurethane foam-coated implant by F.A. Ashley. As a result of additional technical refinements in manufacturing this new implant design significantly reduced complications i.e. capsular contracture and implant rotation. Methods: This study reports a single surgeon’s experience with aesthetic and reconstructive breast surgery, in primary and secondary cases with the sole use of micropolyurethane foam-coated Diagon/gel(®)4Two implants, partly in combination with the additional use of synthetic meshes, acellular dermal matrices and lipofilling. The trial is a prospective, single center cohort study designed to demonstrate the safety and effectiveness of the new implant design in primary and secondary aesthetic and reconstructive breast surgery. The reported data provide an interim report of the implantations performed from November 2010 to December 2013. Results: 90 patients were admitted to the study with 152 implants. The majority of the implants (n=95, 62.5%) were used in reoperative cases for either oncological (n=52, 34.2%) or aesthetic reasons (n=43, 28.3%). The median age of the study cohort was 45 years; the median body mass index was 21; the median observation time is 41 months. There was a very low complication rate, both short term within 6 weeks after the implantation of the silicone gel implant and in the follow up in November 2015. There were no serious complications needing explantation, no capsular fibrosis or implant rotation or rupture so far. There were only 4 minor complications (1.97%). There was 1 local recurrence 4 years after skin and nipple sparing mastectomy. Conclusion: The micropolyurethane foam-coated Diagon/gel(®)4Two implant is a very reliable silicone gel implant filled with two high cross-linked, cohesive and form stable gels. The study demonstrated a very high safety profile of the 4Two implant and its effectiveness in both primary and secondary reoperative aesthetic, oncological and reconstructive breast surgery. The study is ongoing, a longer follow-up will be needed to consolidate the data. German Medical Science GMS Publishing House 2015-12-21 /pmc/articles/PMC4686800/ /pubmed/26713264 http://dx.doi.org/10.3205/iprs000079 Text en Copyright © 2015 Brunnert http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.
spellingShingle Article
Brunnert, Klaus E.
The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
title The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
title_full The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
title_fullStr The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
title_full_unstemmed The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
title_short The micropolyurethane foam-coated Diagon/Gel(®)4Two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
title_sort micropolyurethane foam-coated diagon/gel(®)4two implant in aesthetic and reconstructive breast surgery – 3-year results of an ongoing study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686800/
https://www.ncbi.nlm.nih.gov/pubmed/26713264
http://dx.doi.org/10.3205/iprs000079
work_keys_str_mv AT brunnertklause themicropolyurethanefoamcoateddiagongel4twoimplantinaestheticandreconstructivebreastsurgery3yearresultsofanongoingstudy
AT brunnertklause micropolyurethanefoamcoateddiagongel4twoimplantinaestheticandreconstructivebreastsurgery3yearresultsofanongoingstudy