Advances in the development of an imaging device for plaque measurement in the area of the carotid artery
This paper describes the advances in the development and subsequent testing of an imaging device for three-dimensional ultrasound measurement of atherosclerotic plaque in the carotid artery. The embolization from the atherosclerotic carotid plaque is one of the most common causes of ischemic stroke...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686974/ https://www.ncbi.nlm.nih.gov/pubmed/26740760 http://dx.doi.org/10.1080/13102818.2014.910362 |
_version_ | 1782406538384637952 |
---|---|
author | Ličev, Lačezar Krumnikl, Michal Škuta, Jaromír Babiuch, Marek Farana, Radim |
author_facet | Ličev, Lačezar Krumnikl, Michal Škuta, Jaromír Babiuch, Marek Farana, Radim |
author_sort | Ličev, Lačezar |
collection | PubMed |
description | This paper describes the advances in the development and subsequent testing of an imaging device for three-dimensional ultrasound measurement of atherosclerotic plaque in the carotid artery. The embolization from the atherosclerotic carotid plaque is one of the most common causes of ischemic stroke and, therefore, we consider the measurement of the plaque as extremely important. The paper describes the proposed hardware for enhancing the standard ultrasonic probe to provide a possibility of accurate probe positioning and synchronization with the cardiac activity, allowing the precise plaque measurements that were impossible with the standard equipment. The synchronization signal is derived from the output signal of the patient monitor (electrocardiogram (ECG)), processed by a microcontroller-based system, generating the control commands for the linear motion moving the probe. The controlling algorithm synchronizes the movement with the ECG waveform to obtain clear images not disturbed by the heart activity. |
format | Online Article Text |
id | pubmed-4686974 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-46869742016-01-04 Advances in the development of an imaging device for plaque measurement in the area of the carotid artery Ličev, Lačezar Krumnikl, Michal Škuta, Jaromír Babiuch, Marek Farana, Radim Biotechnol Biotechnol Equip Article; Biotechnological Equipment This paper describes the advances in the development and subsequent testing of an imaging device for three-dimensional ultrasound measurement of atherosclerotic plaque in the carotid artery. The embolization from the atherosclerotic carotid plaque is one of the most common causes of ischemic stroke and, therefore, we consider the measurement of the plaque as extremely important. The paper describes the proposed hardware for enhancing the standard ultrasonic probe to provide a possibility of accurate probe positioning and synchronization with the cardiac activity, allowing the precise plaque measurements that were impossible with the standard equipment. The synchronization signal is derived from the output signal of the patient monitor (electrocardiogram (ECG)), processed by a microcontroller-based system, generating the control commands for the linear motion moving the probe. The controlling algorithm synchronizes the movement with the ECG waveform to obtain clear images not disturbed by the heart activity. Taylor & Francis 2014-03-04 2014-07-08 /pmc/articles/PMC4686974/ /pubmed/26740760 http://dx.doi.org/10.1080/13102818.2014.910362 Text en © 2014 The Author(s). Published by Taylor & Francis. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The moral rights of the named author(s) have been asserted. |
spellingShingle | Article; Biotechnological Equipment Ličev, Lačezar Krumnikl, Michal Škuta, Jaromír Babiuch, Marek Farana, Radim Advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
title | Advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
title_full | Advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
title_fullStr | Advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
title_full_unstemmed | Advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
title_short | Advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
title_sort | advances in the development of an imaging device for plaque measurement in the area of the carotid artery |
topic | Article; Biotechnological Equipment |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4686974/ https://www.ncbi.nlm.nih.gov/pubmed/26740760 http://dx.doi.org/10.1080/13102818.2014.910362 |
work_keys_str_mv | AT licevlacezar advancesinthedevelopmentofanimagingdeviceforplaquemeasurementintheareaofthecarotidartery AT krumniklmichal advancesinthedevelopmentofanimagingdeviceforplaquemeasurementintheareaofthecarotidartery AT skutajaromir advancesinthedevelopmentofanimagingdeviceforplaquemeasurementintheareaofthecarotidartery AT babiuchmarek advancesinthedevelopmentofanimagingdeviceforplaquemeasurementintheareaofthecarotidartery AT faranaradim advancesinthedevelopmentofanimagingdeviceforplaquemeasurementintheareaofthecarotidartery |