Cargando…

Graft Biomechanics Following Three Corneal Transplantation Techniques

PURPOSE: To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. METHODS: This...

Descripción completa

Detalles Bibliográficos
Autores principales: Feizi, Sepehr, Montahai, Talieh, Moein, Hamidreza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4687255/
https://www.ncbi.nlm.nih.gov/pubmed/26730307
http://dx.doi.org/10.4103/2008-322X.170347
_version_ 1782406596938170368
author Feizi, Sepehr
Montahai, Talieh
Moein, Hamidreza
author_facet Feizi, Sepehr
Montahai, Talieh
Moein, Hamidreza
author_sort Feizi, Sepehr
collection PubMed
description PURPOSE: To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. METHODS: This cross-sectional comparative study included 118 eyes: 17 eyes of 17 patients received DSAEK, 23 eyes of 21 patients underwent DALK using Anwar's big bubble technique, and 45 eyes of 36 patients had PK; 33 right eyes of 33 normal subjects served as the control group. Using the ocular response analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, New York, USA), corneal hysteresis (CH) and corneal resistance factor (CRF) were measured and compared among the study groups at least 3 months after all sutures were removed. RESULTS: Mean patient age was 26.9 ± 5.0 years in the control group, 28.8 ± 4.2 in the PK group, 27.2 ± 6.5 in the DALK group, and 62.5 ± 16.8 in the DSAEK group (P < 0.001). Central corneal thickness (CCT) was 539.0 ± 24.8, 567.5 ± 38.8, 547.0 ± 42.6 and 631.1 ± 84.8 μm, respectively (P < 0.001). CH and CRF were significantly lower in the DSAEK group (7.79 ± 2.0 and 7.88 ± 1.74 mmHg, respectively) as compared to the PK (10.23 ± 2.07 and 10.13 ± 2.22 mmHg, respectively) and DALK (9.64 ± 2.07 and 9.36 ± 2.09 mmHg, respectively) groups. The two latter groups demonstrated biomechanical parameters comparable to normal subjects (9.84 ± 1.59 and 9.89 ± 1.73 mmHg, respectively). CONCLUSION: Graft biomechanical parameters after DSAEK are lower than those following PK and DALK. After PK and DALK in keratoconic eyes, these metrics are increased to normal values. These differences may have implications for interpreting intraocular pressure or planning graft refractive surgery after keratoplasty.
format Online
Article
Text
id pubmed-4687255
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-46872552016-01-04 Graft Biomechanics Following Three Corneal Transplantation Techniques Feizi, Sepehr Montahai, Talieh Moein, Hamidreza J Ophthalmic Vis Res Original Article PURPOSE: To compare corneal biomechanical properties following three different transplantation techniques, including Descemet stripping automated endothelial keratoplasty (DSAEK), deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in comparison to normal eyes. METHODS: This cross-sectional comparative study included 118 eyes: 17 eyes of 17 patients received DSAEK, 23 eyes of 21 patients underwent DALK using Anwar's big bubble technique, and 45 eyes of 36 patients had PK; 33 right eyes of 33 normal subjects served as the control group. Using the ocular response analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, New York, USA), corneal hysteresis (CH) and corneal resistance factor (CRF) were measured and compared among the study groups at least 3 months after all sutures were removed. RESULTS: Mean patient age was 26.9 ± 5.0 years in the control group, 28.8 ± 4.2 in the PK group, 27.2 ± 6.5 in the DALK group, and 62.5 ± 16.8 in the DSAEK group (P < 0.001). Central corneal thickness (CCT) was 539.0 ± 24.8, 567.5 ± 38.8, 547.0 ± 42.6 and 631.1 ± 84.8 μm, respectively (P < 0.001). CH and CRF were significantly lower in the DSAEK group (7.79 ± 2.0 and 7.88 ± 1.74 mmHg, respectively) as compared to the PK (10.23 ± 2.07 and 10.13 ± 2.22 mmHg, respectively) and DALK (9.64 ± 2.07 and 9.36 ± 2.09 mmHg, respectively) groups. The two latter groups demonstrated biomechanical parameters comparable to normal subjects (9.84 ± 1.59 and 9.89 ± 1.73 mmHg, respectively). CONCLUSION: Graft biomechanical parameters after DSAEK are lower than those following PK and DALK. After PK and DALK in keratoconic eyes, these metrics are increased to normal values. These differences may have implications for interpreting intraocular pressure or planning graft refractive surgery after keratoplasty. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4687255/ /pubmed/26730307 http://dx.doi.org/10.4103/2008-322X.170347 Text en Copyright: © 2015 Journal of Ophthalmic and Vision Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Feizi, Sepehr
Montahai, Talieh
Moein, Hamidreza
Graft Biomechanics Following Three Corneal Transplantation Techniques
title Graft Biomechanics Following Three Corneal Transplantation Techniques
title_full Graft Biomechanics Following Three Corneal Transplantation Techniques
title_fullStr Graft Biomechanics Following Three Corneal Transplantation Techniques
title_full_unstemmed Graft Biomechanics Following Three Corneal Transplantation Techniques
title_short Graft Biomechanics Following Three Corneal Transplantation Techniques
title_sort graft biomechanics following three corneal transplantation techniques
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4687255/
https://www.ncbi.nlm.nih.gov/pubmed/26730307
http://dx.doi.org/10.4103/2008-322X.170347
work_keys_str_mv AT feizisepehr graftbiomechanicsfollowingthreecornealtransplantationtechniques
AT montahaitalieh graftbiomechanicsfollowingthreecornealtransplantationtechniques
AT moeinhamidreza graftbiomechanicsfollowingthreecornealtransplantationtechniques