Cargando…

Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()

INTRODUCTION: Objective evaluation of sleep bruxism (SB) using whole-night polysomnography (PSG) is relevant for diagnostic confirmation. Nevertheless, the PSG electromyogram (EMG) scoring may give rise to controversy, particularly when audiovisual monitoring is not performed. Therefore, the present...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferraz, Otávio, de Moura Guimarães, Thais, Maluly Filho, Milton, Dal-Fabbro, Cibele, Abraão Crosara Cunha, Thays, Cristina Lotaif, Ana, Cristina Barros Schütz, Teresa, Santos-Silva, Rogério, Tufik, Sergio, Bittencourt, Lia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4688588/
https://www.ncbi.nlm.nih.gov/pubmed/26779318
http://dx.doi.org/10.1016/j.slsci.2015.08.002
_version_ 1782406746324598784
author Ferraz, Otávio
de Moura Guimarães, Thais
Maluly Filho, Milton
Dal-Fabbro, Cibele
Abraão Crosara Cunha, Thays
Cristina Lotaif, Ana
Cristina Barros Schütz, Teresa
Santos-Silva, Rogério
Tufik, Sergio
Bittencourt, Lia
author_facet Ferraz, Otávio
de Moura Guimarães, Thais
Maluly Filho, Milton
Dal-Fabbro, Cibele
Abraão Crosara Cunha, Thays
Cristina Lotaif, Ana
Cristina Barros Schütz, Teresa
Santos-Silva, Rogério
Tufik, Sergio
Bittencourt, Lia
author_sort Ferraz, Otávio
collection PubMed
description INTRODUCTION: Objective evaluation of sleep bruxism (SB) using whole-night polysomnography (PSG) is relevant for diagnostic confirmation. Nevertheless, the PSG electromyogram (EMG) scoring may give rise to controversy, particularly when audiovisual monitoring is not performed. Therefore, the present study assessed the concordance between two independent scorers to visual SB on a PSG performed without audiovisual monitoring. METHODS: Fifty-six PSG tests were scored from individuals with clinical history and polysomnography criteria of SB. In addition to the protocol of conventional whole-night PSG, electrodes were also placed bilaterally on the masseter and temporal muscles. Visual EMG scoring without audio video monitoring was scored by two independent scorers (Dentist 1 and Dentist 2) according the recommendations formulated in the AASM manual (2007). Kendall Tau correlation was used to assess interobserver concordance relative to variables “total duration of events (seconds), “shortest events”, “longest events” and index in each phasic, tonic or mixed event. RESULTS: The correlation was positive and significant relative to all the investigated variables, being T>0.54. CONCLUSION: It was found a good inter-examiner concordance rate in SB scoring in absence of audio video monitoring.
format Online
Article
Text
id pubmed-4688588
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-46885882016-01-15 Assessment of interobserver concordance in polysomnography scoring of sleep bruxism() Ferraz, Otávio de Moura Guimarães, Thais Maluly Filho, Milton Dal-Fabbro, Cibele Abraão Crosara Cunha, Thays Cristina Lotaif, Ana Cristina Barros Schütz, Teresa Santos-Silva, Rogério Tufik, Sergio Bittencourt, Lia Sleep Sci Full-Length Article INTRODUCTION: Objective evaluation of sleep bruxism (SB) using whole-night polysomnography (PSG) is relevant for diagnostic confirmation. Nevertheless, the PSG electromyogram (EMG) scoring may give rise to controversy, particularly when audiovisual monitoring is not performed. Therefore, the present study assessed the concordance between two independent scorers to visual SB on a PSG performed without audiovisual monitoring. METHODS: Fifty-six PSG tests were scored from individuals with clinical history and polysomnography criteria of SB. In addition to the protocol of conventional whole-night PSG, electrodes were also placed bilaterally on the masseter and temporal muscles. Visual EMG scoring without audio video monitoring was scored by two independent scorers (Dentist 1 and Dentist 2) according the recommendations formulated in the AASM manual (2007). Kendall Tau correlation was used to assess interobserver concordance relative to variables “total duration of events (seconds), “shortest events”, “longest events” and index in each phasic, tonic or mixed event. RESULTS: The correlation was positive and significant relative to all the investigated variables, being T>0.54. CONCLUSION: It was found a good inter-examiner concordance rate in SB scoring in absence of audio video monitoring. Elsevier 2015-11 2015-08-25 /pmc/articles/PMC4688588/ /pubmed/26779318 http://dx.doi.org/10.1016/j.slsci.2015.08.002 Text en © 2015 Brazilian Association of Sleep. Production and Hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Full-Length Article
Ferraz, Otávio
de Moura Guimarães, Thais
Maluly Filho, Milton
Dal-Fabbro, Cibele
Abraão Crosara Cunha, Thays
Cristina Lotaif, Ana
Cristina Barros Schütz, Teresa
Santos-Silva, Rogério
Tufik, Sergio
Bittencourt, Lia
Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
title Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
title_full Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
title_fullStr Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
title_full_unstemmed Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
title_short Assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
title_sort assessment of interobserver concordance in polysomnography scoring of sleep bruxism()
topic Full-Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4688588/
https://www.ncbi.nlm.nih.gov/pubmed/26779318
http://dx.doi.org/10.1016/j.slsci.2015.08.002
work_keys_str_mv AT ferrazotavio assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT demouraguimaraesthais assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT malulyfilhomilton assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT dalfabbrocibele assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT abraaocrosaracunhathays assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT cristinalotaifana assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT cristinabarrosschutzteresa assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT santossilvarogerio assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT tufiksergio assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism
AT bittencourtlia assessmentofinterobserverconcordanceinpolysomnographyscoringofsleepbruxism