Cargando…
Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool
BACKGROUND: Magnetic resonance imaging (MRI) is the standard neuroimaging method to diagnose neoplastic brain lesions, as well as to perform stereotactic biopsy surgical planning. MRI has the advantage of providing structural anatomical details with high sensitivity, though histological specificity...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4689263/ https://www.ncbi.nlm.nih.gov/pubmed/26719708 http://dx.doi.org/10.2147/OTT.S87126 |
_version_ | 1782406818205532160 |
---|---|
author | Lopez, William Omar Contreras Cordeiro, Joacir Graciolli Albicker, Ulrich Doostkam, Soroush Nikkhah, Guido Kirch, Robert D Trippel, Michael Reithmeier, Thomas |
author_facet | Lopez, William Omar Contreras Cordeiro, Joacir Graciolli Albicker, Ulrich Doostkam, Soroush Nikkhah, Guido Kirch, Robert D Trippel, Michael Reithmeier, Thomas |
author_sort | Lopez, William Omar Contreras |
collection | PubMed |
description | BACKGROUND: Magnetic resonance imaging (MRI) is the standard neuroimaging method to diagnose neoplastic brain lesions, as well as to perform stereotactic biopsy surgical planning. MRI has the advantage of providing structural anatomical details with high sensitivity, though histological specificity is limited. Although combining MRI with other imaging modalities, such as positron-emission tomography (PET), has proven to increment specificity, exact correlation between PET threshold uptake ratios (URs) and histological diagnosis and grading has not yet been described. OBJECTIVES: The aim of this study was to correlate exactly the histopathological criteria of the biopsy site to its PET uptake value with high spatial resolution (mm(3)), and to analyze the diagnostic value of PET using the amino acid O-(2-[(18)F]fluoroethyl)-l-tyrosine ((18)F-FET) PET in patients with newly diagnosed brain lesions in comparison to histological findings obtained from stereotactic serial biopsy. PATIENTS AND METHODS: A total of 23 adult patients with newly diagnosed brain tumors on MRI were enrolled in this study. Subsequently to diagnoses, all patients underwent a (18)F-FET PET-guided stereotactic biopsy, using an original newly developed software module, which is presented here. Conventional MRI, stereotactic computed tomography series, and (18)F-FET PET images were semiautomatically fused, and hot-spot detection was performed for target planning. UR was determined using the uptake value from the biopsy sites in relation to the contralateral frontal white matter. UR values ≥1.6 were considered positive for glioma. High-grade glioma (HGG) was suspected with URs ≥3.0, while low-grade glioma (LGG) was suspected with URs between 1.6 and 3.0. Stereotactic serial biopsies along the trajectory at multiple sites were performed in millimeter steps, and the FET URs for each site were correlated exactly with a panel of 27 different histopathological markers. Comparisons between FET URs along the biopsy trajectories and the histological diagnoses were made with Pearson product-moment correlation coefficients. Analysis of variance was performed to test for significant differences in maximum UR between different tumor grades. RESULTS: A total of 363 biopsy specimens were taken from 23 patients by stereotactic serial biopsies. Histological examination revealed eight patients (35%) with an LGG: one with a World Health Organization (WHO)-I lesion and seven with a WHO-II lesion. Thirteen (57%) patients revealed an HGG (two with a WHO-III and three with a WHO-IV tumor), and two patients (9%) showed a process that was neither HGG nor LGG (group X or no-grade group). The correlation matrix between histological findings and the UR revealed five strong correlations. Low cell density in tissue samples was found to have a significant negative correlation with the measured cortical uptake rate (r=−0.43, P=0.02), as well as moderate cell density (r=−0.48, P=0.02). Pathological patterns of proliferation (r=0.37, P=0.04), GFAP (r=0.37, P=0.04), and Olig2 (r=0.36, P=0.05) showed a significant positive correlation with cortical URs. Analysis of variance tests showed a significant difference between the LGG and the HGG groups (F=8.27, P<0.002), but no significant differences when differentiating between the X group and the HGG (P=0.2)/LGG (P=0.8) groups, nor between the no-grade group and the WHO-I group. CONCLUSION: (18)F-FET PET is a valuable tool, as it allows the differentiation of HGGs from LGGs. Its use is not limited to preoperative evaluation; it may also refine biopsy targeting and improve tumor delimitation for radiotherapy. Histology is still necessary, and remains the gold standard for definitive diagnosis of brain lesions. |
format | Online Article Text |
id | pubmed-4689263 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-46892632015-12-30 Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool Lopez, William Omar Contreras Cordeiro, Joacir Graciolli Albicker, Ulrich Doostkam, Soroush Nikkhah, Guido Kirch, Robert D Trippel, Michael Reithmeier, Thomas Onco Targets Ther Original Research BACKGROUND: Magnetic resonance imaging (MRI) is the standard neuroimaging method to diagnose neoplastic brain lesions, as well as to perform stereotactic biopsy surgical planning. MRI has the advantage of providing structural anatomical details with high sensitivity, though histological specificity is limited. Although combining MRI with other imaging modalities, such as positron-emission tomography (PET), has proven to increment specificity, exact correlation between PET threshold uptake ratios (URs) and histological diagnosis and grading has not yet been described. OBJECTIVES: The aim of this study was to correlate exactly the histopathological criteria of the biopsy site to its PET uptake value with high spatial resolution (mm(3)), and to analyze the diagnostic value of PET using the amino acid O-(2-[(18)F]fluoroethyl)-l-tyrosine ((18)F-FET) PET in patients with newly diagnosed brain lesions in comparison to histological findings obtained from stereotactic serial biopsy. PATIENTS AND METHODS: A total of 23 adult patients with newly diagnosed brain tumors on MRI were enrolled in this study. Subsequently to diagnoses, all patients underwent a (18)F-FET PET-guided stereotactic biopsy, using an original newly developed software module, which is presented here. Conventional MRI, stereotactic computed tomography series, and (18)F-FET PET images were semiautomatically fused, and hot-spot detection was performed for target planning. UR was determined using the uptake value from the biopsy sites in relation to the contralateral frontal white matter. UR values ≥1.6 were considered positive for glioma. High-grade glioma (HGG) was suspected with URs ≥3.0, while low-grade glioma (LGG) was suspected with URs between 1.6 and 3.0. Stereotactic serial biopsies along the trajectory at multiple sites were performed in millimeter steps, and the FET URs for each site were correlated exactly with a panel of 27 different histopathological markers. Comparisons between FET URs along the biopsy trajectories and the histological diagnoses were made with Pearson product-moment correlation coefficients. Analysis of variance was performed to test for significant differences in maximum UR between different tumor grades. RESULTS: A total of 363 biopsy specimens were taken from 23 patients by stereotactic serial biopsies. Histological examination revealed eight patients (35%) with an LGG: one with a World Health Organization (WHO)-I lesion and seven with a WHO-II lesion. Thirteen (57%) patients revealed an HGG (two with a WHO-III and three with a WHO-IV tumor), and two patients (9%) showed a process that was neither HGG nor LGG (group X or no-grade group). The correlation matrix between histological findings and the UR revealed five strong correlations. Low cell density in tissue samples was found to have a significant negative correlation with the measured cortical uptake rate (r=−0.43, P=0.02), as well as moderate cell density (r=−0.48, P=0.02). Pathological patterns of proliferation (r=0.37, P=0.04), GFAP (r=0.37, P=0.04), and Olig2 (r=0.36, P=0.05) showed a significant positive correlation with cortical URs. Analysis of variance tests showed a significant difference between the LGG and the HGG groups (F=8.27, P<0.002), but no significant differences when differentiating between the X group and the HGG (P=0.2)/LGG (P=0.8) groups, nor between the no-grade group and the WHO-I group. CONCLUSION: (18)F-FET PET is a valuable tool, as it allows the differentiation of HGGs from LGGs. Its use is not limited to preoperative evaluation; it may also refine biopsy targeting and improve tumor delimitation for radiotherapy. Histology is still necessary, and remains the gold standard for definitive diagnosis of brain lesions. Dove Medical Press 2015-12-17 /pmc/articles/PMC4689263/ /pubmed/26719708 http://dx.doi.org/10.2147/OTT.S87126 Text en © 2015 Lopez et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Lopez, William Omar Contreras Cordeiro, Joacir Graciolli Albicker, Ulrich Doostkam, Soroush Nikkhah, Guido Kirch, Robert D Trippel, Michael Reithmeier, Thomas Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
title | Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
title_full | Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
title_fullStr | Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
title_full_unstemmed | Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
title_short | Correlation of (18)F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
title_sort | correlation of (18)f-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4689263/ https://www.ncbi.nlm.nih.gov/pubmed/26719708 http://dx.doi.org/10.2147/OTT.S87126 |
work_keys_str_mv | AT lopezwilliamomarcontreras correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT cordeirojoacirgraciolli correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT albickerulrich correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT doostkamsoroush correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT nikkhahguido correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT kirchrobertd correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT trippelmichael correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool AT reithmeierthomas correlationof18ffluoroethyltyrosinepositronemissiontomographyuptakevaluesandhistomorphologicalfindingsbystereotacticserialbiopsyinnewlydiagnosedbraintumorsusingarefinedsoftwaretool |