Intermediate-term trends in serum levels of metal ions after hip resurfacing arthroplasty
BACKGROUND: The potential risks associated with hip resurfacing arthroplasty (HRA) are controversial and underestimated. The aim of this study was to explore intermediate-term trends for the levels of cobalt (Co), chromium (Cr), and molybdenum (Mo) ions after HRA. METHODS: Forty patients who underwe...
Autores principales: | Jiang, Wenxue, Wan, Yanlin, Cui, Peng, Ning, Xianjia |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4690317/ https://www.ncbi.nlm.nih.gov/pubmed/26698115 http://dx.doi.org/10.1186/s13018-015-0335-0 |
Ejemplares similares
-
Correlation of serum metal ion levels with pathological changes of ARMD in failed metal-on-metal-hip-resurfacing arthroplasties
por: Grammatopoulos, George, et al.
Publicado: (2017) -
Total hip arthroplasty in advanced osteonecrosis: The short-term results by metal-on-metal hip resurfacing
por: Madadi, Firooz, et al.
Publicado: (2011) -
Metal ion levels and functional results after either resurfacing hip arthroplasty or conventional metal-on-metal hip arthroplasty: Short-term outcome of a randomized controlled trial
por: Smolders, José MH, et al.
Publicado: (2011) -
Microseparation, fluid pressure and
flow in failures of metal-on-metal hip resurfacing arthroplasties
por: Wroblewski, B. M., et al.
Publicado: (2012) -
Management Guidelines for Metal-on-metal Hip Resurfacing Arthroplasty: A Strategy on Followup
por: Nakano, Naoki, et al.
Publicado: (2017)