Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms

Despite accounting for the majority of all cerebral aneurysm cases, bifurcation aneurysms present many challenges to standard endovascular treatment techniques. This study examines the treatment of bifurcation aneurysms endovascularly with flow-diverting stents and presents an integrative computatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Peach, T. W., Spranger, K., Ventikos, Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4690836/
https://www.ncbi.nlm.nih.gov/pubmed/26240061
http://dx.doi.org/10.1007/s10439-015-1395-3
_version_ 1782407045507448832
author Peach, T. W.
Spranger, K.
Ventikos, Y.
author_facet Peach, T. W.
Spranger, K.
Ventikos, Y.
author_sort Peach, T. W.
collection PubMed
description Despite accounting for the majority of all cerebral aneurysm cases, bifurcation aneurysms present many challenges to standard endovascular treatment techniques. This study examines the treatment of bifurcation aneurysms endovascularly with flow-diverting stents and presents an integrative computational modeling suite allowing for rehearsing all aspects of the treatment. Six bifurcation aneurysms are virtually treated with 70% porosity flow-diverters. Substantial reduction (>50%) in aneurysm inflow due to device deployment is predicted in addition to reductions in peak and average aneurysm wall shear stress to values considered physiologically normal. The subsequent impact of flow-diverter deployment on daughter vessels that are jailed by the device is investigated further, with a number of simulations conducted with increased outlet pressure conditions at jailed vessels. Increased outlet pressures at jailed daughter vessels are found to have little effect on device-induced aneurysm inflow reduction, but large variation (13–86%) is seen in the resulting reduction in daughter vessel flow rate. Finally, we propose a potentially powerful approach for validation of such models, by introducing an angiographic contrast model, with contrast transport modeled both before and after virtual treatment. Virtual angiograms and contrast residence curves are created, which offer unique clinical relevance and the potential for future in vivo verification of simulated results.
format Online
Article
Text
id pubmed-4690836
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-46908362015-12-31 Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms Peach, T. W. Spranger, K. Ventikos, Y. Ann Biomed Eng Computational Biomechanics for Patient-Specific Applications Despite accounting for the majority of all cerebral aneurysm cases, bifurcation aneurysms present many challenges to standard endovascular treatment techniques. This study examines the treatment of bifurcation aneurysms endovascularly with flow-diverting stents and presents an integrative computational modeling suite allowing for rehearsing all aspects of the treatment. Six bifurcation aneurysms are virtually treated with 70% porosity flow-diverters. Substantial reduction (>50%) in aneurysm inflow due to device deployment is predicted in addition to reductions in peak and average aneurysm wall shear stress to values considered physiologically normal. The subsequent impact of flow-diverter deployment on daughter vessels that are jailed by the device is investigated further, with a number of simulations conducted with increased outlet pressure conditions at jailed vessels. Increased outlet pressures at jailed daughter vessels are found to have little effect on device-induced aneurysm inflow reduction, but large variation (13–86%) is seen in the resulting reduction in daughter vessel flow rate. Finally, we propose a potentially powerful approach for validation of such models, by introducing an angiographic contrast model, with contrast transport modeled both before and after virtual treatment. Virtual angiograms and contrast residence curves are created, which offer unique clinical relevance and the potential for future in vivo verification of simulated results. Springer US 2015-08-04 2016 /pmc/articles/PMC4690836/ /pubmed/26240061 http://dx.doi.org/10.1007/s10439-015-1395-3 Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Computational Biomechanics for Patient-Specific Applications
Peach, T. W.
Spranger, K.
Ventikos, Y.
Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
title Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
title_full Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
title_fullStr Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
title_full_unstemmed Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
title_short Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms
title_sort towards predicting patient-specific flow-diverter treatment outcomes for bifurcation aneurysms: from implantation rehearsal to virtual angiograms
topic Computational Biomechanics for Patient-Specific Applications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4690836/
https://www.ncbi.nlm.nih.gov/pubmed/26240061
http://dx.doi.org/10.1007/s10439-015-1395-3
work_keys_str_mv AT peachtw towardspredictingpatientspecificflowdivertertreatmentoutcomesforbifurcationaneurysmsfromimplantationrehearsaltovirtualangiograms
AT sprangerk towardspredictingpatientspecificflowdivertertreatmentoutcomesforbifurcationaneurysmsfromimplantationrehearsaltovirtualangiograms
AT ventikosy towardspredictingpatientspecificflowdivertertreatmentoutcomesforbifurcationaneurysmsfromimplantationrehearsaltovirtualangiograms