Cargando…
Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers
MscL, a large conductance mechanosensitive channel (MSC), is a ubiquitous osmolyte release valve that helps bacteria survive abrupt hypo-osmotic shocks. It has been discovered and rigorously studied using the patch-clamp technique for almost three decades. Its basic role of translating tension appli...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MyJove Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4692740/ https://www.ncbi.nlm.nih.gov/pubmed/26650467 http://dx.doi.org/10.3791/53362 |
_version_ | 1782407287128719360 |
---|---|
author | Najem, Joseph S. Dunlap, Myles D. Yasmann, Anthony Freeman, Eric C. Grant, John W. Sukharev, Sergei Leo, Donald J. |
author_facet | Najem, Joseph S. Dunlap, Myles D. Yasmann, Anthony Freeman, Eric C. Grant, John W. Sukharev, Sergei Leo, Donald J. |
author_sort | Najem, Joseph S. |
collection | PubMed |
description | MscL, a large conductance mechanosensitive channel (MSC), is a ubiquitous osmolyte release valve that helps bacteria survive abrupt hypo-osmotic shocks. It has been discovered and rigorously studied using the patch-clamp technique for almost three decades. Its basic role of translating tension applied to the cell membrane into permeability response makes it a strong candidate to function as a mechanoelectrical transducer in artificial membrane-based biomolecular devices. Serving as building blocks to such devices, droplet interface bilayers (DIBs) can be used as a new platform for the incorporation and stimulation of MscL channels. Here, we describe a micropipette-based method to form DIBs and measure the activity of the incorporated MscL channels. This method consists of lipid-encased aqueous droplets anchored to the tips of two opposing (coaxially positioned) borosilicate glass micropipettes. When droplets are brought into contact, a lipid bilayer interface is formed. This technique offers control over the chemical composition and the size of each droplet, as well as the dimensions of the bilayer interface. Having one of the micropipettes attached to a harmonic piezoelectric actuator provides the ability to deliver a desired oscillatory stimulus. Through analysis of the shapes of the droplets during deformation, the tension created at the interface can be estimated. Using this technique, the first activity of MscL channels in a DIB system is reported. Besides MS channels, activities of other types of channels can be studied using this method, proving the multi-functionality of this platform. The method presented here enables the measurement of fundamental membrane properties, provides a greater control over the formation of symmetric and asymmetric membranes, and is an alternative way to stimulate and study mechanosensitive channels. |
format | Online Article Text |
id | pubmed-4692740 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MyJove Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46927402016-01-07 Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers Najem, Joseph S. Dunlap, Myles D. Yasmann, Anthony Freeman, Eric C. Grant, John W. Sukharev, Sergei Leo, Donald J. J Vis Exp Bioengineering MscL, a large conductance mechanosensitive channel (MSC), is a ubiquitous osmolyte release valve that helps bacteria survive abrupt hypo-osmotic shocks. It has been discovered and rigorously studied using the patch-clamp technique for almost three decades. Its basic role of translating tension applied to the cell membrane into permeability response makes it a strong candidate to function as a mechanoelectrical transducer in artificial membrane-based biomolecular devices. Serving as building blocks to such devices, droplet interface bilayers (DIBs) can be used as a new platform for the incorporation and stimulation of MscL channels. Here, we describe a micropipette-based method to form DIBs and measure the activity of the incorporated MscL channels. This method consists of lipid-encased aqueous droplets anchored to the tips of two opposing (coaxially positioned) borosilicate glass micropipettes. When droplets are brought into contact, a lipid bilayer interface is formed. This technique offers control over the chemical composition and the size of each droplet, as well as the dimensions of the bilayer interface. Having one of the micropipettes attached to a harmonic piezoelectric actuator provides the ability to deliver a desired oscillatory stimulus. Through analysis of the shapes of the droplets during deformation, the tension created at the interface can be estimated. Using this technique, the first activity of MscL channels in a DIB system is reported. Besides MS channels, activities of other types of channels can be studied using this method, proving the multi-functionality of this platform. The method presented here enables the measurement of fundamental membrane properties, provides a greater control over the formation of symmetric and asymmetric membranes, and is an alternative way to stimulate and study mechanosensitive channels. MyJove Corporation 2015-11-19 /pmc/articles/PMC4692740/ /pubmed/26650467 http://dx.doi.org/10.3791/53362 Text en Copyright © 2015, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Bioengineering Najem, Joseph S. Dunlap, Myles D. Yasmann, Anthony Freeman, Eric C. Grant, John W. Sukharev, Sergei Leo, Donald J. Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers |
title | Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers |
title_full | Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers |
title_fullStr | Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers |
title_full_unstemmed | Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers |
title_short | Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers |
title_sort | multifunctional, micropipette-based method for incorporation and stimulation of bacterial mechanosensitive ion channels in droplet interface bilayers |
topic | Bioengineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4692740/ https://www.ncbi.nlm.nih.gov/pubmed/26650467 http://dx.doi.org/10.3791/53362 |
work_keys_str_mv | AT najemjosephs multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers AT dunlapmylesd multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers AT yasmannanthony multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers AT freemanericc multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers AT grantjohnw multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers AT sukharevsergei multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers AT leodonaldj multifunctionalmicropipettebasedmethodforincorporationandstimulationofbacterialmechanosensitiveionchannelsindropletinterfacebilayers |