Cargando…
A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software
We established a novel measurement technique to evaluate the anatomic information of nutrient artery canals using Mimics (Materialise's Interactive Medical Image Control System) software, which will provide full knowledge of nutrient artery canals to assist in the diagnosis of longitudinal frac...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4692976/ https://www.ncbi.nlm.nih.gov/pubmed/26788498 http://dx.doi.org/10.1155/2015/171672 |
_version_ | 1782407298719678464 |
---|---|
author | Li, Jiantao Zhang, Hao Yin, Peng Su, Xiuyun Zhao, Zhe Zhou, Jianfeng Li, Chen Li, Zhirui Zhang, Lihai Tang, Peifu |
author_facet | Li, Jiantao Zhang, Hao Yin, Peng Su, Xiuyun Zhao, Zhe Zhou, Jianfeng Li, Chen Li, Zhirui Zhang, Lihai Tang, Peifu |
author_sort | Li, Jiantao |
collection | PubMed |
description | We established a novel measurement technique to evaluate the anatomic information of nutrient artery canals using Mimics (Materialise's Interactive Medical Image Control System) software, which will provide full knowledge of nutrient artery canals to assist in the diagnosis of longitudinal fractures of tibia and choosing an optimal therapy. Here we collected Digital Imaging and Communications in Medicine (DICOM) format of 199 patients hospitalized in our hospital. All three-dimensional models of tibia in Mimics were reconstructed. In 3-matic software, we marked five points in tibia which located at intercondylar eminence, tibia tuberosity, outer ostium, inner ostium, and bottom of medial malleolus. We then recorded Z-coordinates values of the five points and performed statistical analysis. Our results indicate that foramen was found to be absent in 9 (2.3%) tibias, and 379 (95.2%) tibias had single nutrient foramen. The double foramina was observed in 10 (2.5%) tibias. The mean of tibia length was 358 ± 22 mm. The mean foraminal index was 31.8% ± 3%. The mean distance between tibial tuberosity and foramen (TFD) is 66 ± 12 mm. Foraminal index has significant positive correlation with TFD (r = 0.721, P < 0.01). Length of nutrient artery canals has significant negative correlation with TFD (r = −0.340, P < 0.01) and has significant negative correlation with foraminal index (r = −0.541, P < 0.01). |
format | Online Article Text |
id | pubmed-4692976 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-46929762016-01-19 A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software Li, Jiantao Zhang, Hao Yin, Peng Su, Xiuyun Zhao, Zhe Zhou, Jianfeng Li, Chen Li, Zhirui Zhang, Lihai Tang, Peifu Biomed Res Int Research Article We established a novel measurement technique to evaluate the anatomic information of nutrient artery canals using Mimics (Materialise's Interactive Medical Image Control System) software, which will provide full knowledge of nutrient artery canals to assist in the diagnosis of longitudinal fractures of tibia and choosing an optimal therapy. Here we collected Digital Imaging and Communications in Medicine (DICOM) format of 199 patients hospitalized in our hospital. All three-dimensional models of tibia in Mimics were reconstructed. In 3-matic software, we marked five points in tibia which located at intercondylar eminence, tibia tuberosity, outer ostium, inner ostium, and bottom of medial malleolus. We then recorded Z-coordinates values of the five points and performed statistical analysis. Our results indicate that foramen was found to be absent in 9 (2.3%) tibias, and 379 (95.2%) tibias had single nutrient foramen. The double foramina was observed in 10 (2.5%) tibias. The mean of tibia length was 358 ± 22 mm. The mean foraminal index was 31.8% ± 3%. The mean distance between tibial tuberosity and foramen (TFD) is 66 ± 12 mm. Foraminal index has significant positive correlation with TFD (r = 0.721, P < 0.01). Length of nutrient artery canals has significant negative correlation with TFD (r = −0.340, P < 0.01) and has significant negative correlation with foraminal index (r = −0.541, P < 0.01). Hindawi Publishing Corporation 2015 2015-12-15 /pmc/articles/PMC4692976/ /pubmed/26788498 http://dx.doi.org/10.1155/2015/171672 Text en Copyright © 2015 Jiantao Li et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Li, Jiantao Zhang, Hao Yin, Peng Su, Xiuyun Zhao, Zhe Zhou, Jianfeng Li, Chen Li, Zhirui Zhang, Lihai Tang, Peifu A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software |
title | A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software |
title_full | A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software |
title_fullStr | A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software |
title_full_unstemmed | A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software |
title_short | A New Measurement Technique of the Characteristics of Nutrient Artery Canals in Tibias Using Materialise's Interactive Medical Image Control System Software |
title_sort | new measurement technique of the characteristics of nutrient artery canals in tibias using materialise's interactive medical image control system software |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4692976/ https://www.ncbi.nlm.nih.gov/pubmed/26788498 http://dx.doi.org/10.1155/2015/171672 |
work_keys_str_mv | AT lijiantao anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhanghao anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT yinpeng anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT suxiuyun anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhaozhe anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhoujianfeng anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT lichen anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT lizhirui anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhanglihai anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT tangpeifu anewmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT lijiantao newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhanghao newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT yinpeng newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT suxiuyun newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhaozhe newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhoujianfeng newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT lichen newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT lizhirui newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT zhanglihai newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware AT tangpeifu newmeasurementtechniqueofthecharacteristicsofnutrientarterycanalsintibiasusingmaterialisesinteractivemedicalimagecontrolsystemsoftware |