Cargando…

A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans

BACKGROUND: The choice of any radiotherapy treatment plan is usually made after the evaluation of a few preliminary isodose distributions obtained from different beam configurations. Despite considerable advances in planning techniques, such final decision remains a challenging task that would great...

Descripción completa

Detalles Bibliográficos
Autores principales: L. Alfonso, J. C., Herrero, M. A., Núñez, L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4696205/
https://www.ncbi.nlm.nih.gov/pubmed/26715096
http://dx.doi.org/10.1186/s13014-015-0569-3
_version_ 1782407749709070336
author L. Alfonso, J. C.
Herrero, M. A.
Núñez, L.
author_facet L. Alfonso, J. C.
Herrero, M. A.
Núñez, L.
author_sort L. Alfonso, J. C.
collection PubMed
description BACKGROUND: The choice of any radiotherapy treatment plan is usually made after the evaluation of a few preliminary isodose distributions obtained from different beam configurations. Despite considerable advances in planning techniques, such final decision remains a challenging task that would greatly benefit from efficient and reliable assessment tools. METHODS: For any dosimetric plan considered, data on dose-volume histograms supplied by treatment planning systems are used to provide estimates on planning target coverage as well as on sparing of organs at risk and the remaining healthy tissue. These partial metrics are then combined into a dose distribution index (DDI), which provides a unified, easy-to-read score for each competing radiotherapy plan. To assess the performance of the proposed scoring system, DDI figures for fifty brain cancer patients were retrospectively evaluated. Patients were divided in three groups depending on tumor location and malignancy. For each patient, three tentative plans were designed and recorded during planning, one of which was eventually selected for treatment. We thus were able to compare the plans with better DDI scores and those actually delivered. RESULTS: When planning target coverage and organs at risk sparing are considered as equally important, the tentative plan with the highest DDI score is shown to coincide with that actually delivered in 32 of the 50 patients considered. In 15 (respectively 3) of the remaining 18 cases, the plan with highest DDI value still coincides with that actually selected, provided that organs at risk sparing is given higher priority (respectively, lower priority) than target coverage. CONCLUSIONS: DDI provides a straightforward and non-subjective tool for dosimetric comparison of tentative radiotherapy plans. In particular, DDI readily quantifies differences among competing plans with similar-looking dose-volume histograms and can be easily implemented for any tumor type and localization, irrespective of the planning system and irradiation technique considered. Moreover, DDI permits to estimate the dosimetry impact of different priorities being assigned to sparing of organs at risk or to better target coverage.
format Online
Article
Text
id pubmed-4696205
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46962052015-12-31 A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans L. Alfonso, J. C. Herrero, M. A. Núñez, L. Radiat Oncol Research BACKGROUND: The choice of any radiotherapy treatment plan is usually made after the evaluation of a few preliminary isodose distributions obtained from different beam configurations. Despite considerable advances in planning techniques, such final decision remains a challenging task that would greatly benefit from efficient and reliable assessment tools. METHODS: For any dosimetric plan considered, data on dose-volume histograms supplied by treatment planning systems are used to provide estimates on planning target coverage as well as on sparing of organs at risk and the remaining healthy tissue. These partial metrics are then combined into a dose distribution index (DDI), which provides a unified, easy-to-read score for each competing radiotherapy plan. To assess the performance of the proposed scoring system, DDI figures for fifty brain cancer patients were retrospectively evaluated. Patients were divided in three groups depending on tumor location and malignancy. For each patient, three tentative plans were designed and recorded during planning, one of which was eventually selected for treatment. We thus were able to compare the plans with better DDI scores and those actually delivered. RESULTS: When planning target coverage and organs at risk sparing are considered as equally important, the tentative plan with the highest DDI score is shown to coincide with that actually delivered in 32 of the 50 patients considered. In 15 (respectively 3) of the remaining 18 cases, the plan with highest DDI value still coincides with that actually selected, provided that organs at risk sparing is given higher priority (respectively, lower priority) than target coverage. CONCLUSIONS: DDI provides a straightforward and non-subjective tool for dosimetric comparison of tentative radiotherapy plans. In particular, DDI readily quantifies differences among competing plans with similar-looking dose-volume histograms and can be easily implemented for any tumor type and localization, irrespective of the planning system and irradiation technique considered. Moreover, DDI permits to estimate the dosimetry impact of different priorities being assigned to sparing of organs at risk or to better target coverage. BioMed Central 2015-12-29 /pmc/articles/PMC4696205/ /pubmed/26715096 http://dx.doi.org/10.1186/s13014-015-0569-3 Text en © Alfonso et al. 2015 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
L. Alfonso, J. C.
Herrero, M. A.
Núñez, L.
A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
title A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
title_full A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
title_fullStr A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
title_full_unstemmed A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
title_short A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
title_sort dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4696205/
https://www.ncbi.nlm.nih.gov/pubmed/26715096
http://dx.doi.org/10.1186/s13014-015-0569-3
work_keys_str_mv AT lalfonsojc adosevolumehistogrambaseddecisionsupportsystemfordosimetriccomparisonofradiotherapytreatmentplans
AT herreroma adosevolumehistogrambaseddecisionsupportsystemfordosimetriccomparisonofradiotherapytreatmentplans
AT nunezl adosevolumehistogrambaseddecisionsupportsystemfordosimetriccomparisonofradiotherapytreatmentplans
AT lalfonsojc dosevolumehistogrambaseddecisionsupportsystemfordosimetriccomparisonofradiotherapytreatmentplans
AT herreroma dosevolumehistogrambaseddecisionsupportsystemfordosimetriccomparisonofradiotherapytreatmentplans
AT nunezl dosevolumehistogrambaseddecisionsupportsystemfordosimetriccomparisonofradiotherapytreatmentplans