A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip

The identification and characterization, at the cellular level, of cytokine productions present a high interest for both fundamental research and clinical studies. However, the majority of techniques currently available (ELISA, ELISpot, flow cytometry, etc.) have several shortcomings including, nota...

Descripción completa

Detalles Bibliográficos
Autores principales: Baganizi, Dieudonné R., Leroy, Loïc, Laplatine, Loïc, Fairley, Stacie J., Heidmann, Samuel, Menad, Samia, Livache, Thierry, Marche, Patrice N., Roupioz, Yoann
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4697143/
https://www.ncbi.nlm.nih.gov/pubmed/26690235
http://dx.doi.org/10.3390/bios5040750
_version_ 1782407893720498176
author Baganizi, Dieudonné R.
Leroy, Loïc
Laplatine, Loïc
Fairley, Stacie J.
Heidmann, Samuel
Menad, Samia
Livache, Thierry
Marche, Patrice N.
Roupioz, Yoann
author_facet Baganizi, Dieudonné R.
Leroy, Loïc
Laplatine, Loïc
Fairley, Stacie J.
Heidmann, Samuel
Menad, Samia
Livache, Thierry
Marche, Patrice N.
Roupioz, Yoann
author_sort Baganizi, Dieudonné R.
collection PubMed
description The identification and characterization, at the cellular level, of cytokine productions present a high interest for both fundamental research and clinical studies. However, the majority of techniques currently available (ELISA, ELISpot, flow cytometry, etc.) have several shortcomings including, notably, the assessment of several cytokines in relation to individual secreting cells and the monitoring of living cell responses for a long incubation time. In the present work, we describe a system composed of a microfluidic platform coupled with an antibody microarray chip for continuous SPR imaging and immunofluorescence analysis of cytokines (IL-2 and IFN-γ) secreted by T-Lymphocytes, specifically, and stably captured on the biochip under flow upon continued long-term on-chip culture (more than 24 h).
format Online
Article
Text
id pubmed-4697143
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-46971432016-01-19 A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip Baganizi, Dieudonné R. Leroy, Loïc Laplatine, Loïc Fairley, Stacie J. Heidmann, Samuel Menad, Samia Livache, Thierry Marche, Patrice N. Roupioz, Yoann Biosensors (Basel) Article The identification and characterization, at the cellular level, of cytokine productions present a high interest for both fundamental research and clinical studies. However, the majority of techniques currently available (ELISA, ELISpot, flow cytometry, etc.) have several shortcomings including, notably, the assessment of several cytokines in relation to individual secreting cells and the monitoring of living cell responses for a long incubation time. In the present work, we describe a system composed of a microfluidic platform coupled with an antibody microarray chip for continuous SPR imaging and immunofluorescence analysis of cytokines (IL-2 and IFN-γ) secreted by T-Lymphocytes, specifically, and stably captured on the biochip under flow upon continued long-term on-chip culture (more than 24 h). MDPI 2015-12-04 /pmc/articles/PMC4697143/ /pubmed/26690235 http://dx.doi.org/10.3390/bios5040750 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Baganizi, Dieudonné R.
Leroy, Loïc
Laplatine, Loïc
Fairley, Stacie J.
Heidmann, Samuel
Menad, Samia
Livache, Thierry
Marche, Patrice N.
Roupioz, Yoann
A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip
title A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip
title_full A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip
title_fullStr A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip
title_full_unstemmed A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip
title_short A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip
title_sort simple microfluidic platform for long-term analysis and continuous dual-imaging detection of t-cell secreted ifn-γ and il-2 on antibody-based biochip
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4697143/
https://www.ncbi.nlm.nih.gov/pubmed/26690235
http://dx.doi.org/10.3390/bios5040750
work_keys_str_mv AT baganizidieudonner asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT leroyloic asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT laplatineloic asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT fairleystaciej asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT heidmannsamuel asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT menadsamia asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT livachethierry asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT marchepatricen asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT roupiozyoann asimplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT baganizidieudonner simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT leroyloic simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT laplatineloic simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT fairleystaciej simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT heidmannsamuel simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT menadsamia simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT livachethierry simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT marchepatricen simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip
AT roupiozyoann simplemicrofluidicplatformforlongtermanalysisandcontinuousdualimagingdetectionoftcellsecretedifngandil2onantibodybasedbiochip