Cargando…

Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis

BACKGROUND: Occupational sharps injuries are associated with transmission of bloodborne viruses to healthcare workers, including hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Similarly reuse of syringes in healthcare settings might transmit these infection...

Descripción completa

Detalles Bibliográficos
Autores principales: Harb, Alain C., Tarabay, Rami, Diab, Batoul, Ballout, Rami A., Khamassi, Selma, Akl, Elie A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4697323/
https://www.ncbi.nlm.nih.gov/pubmed/26722224
http://dx.doi.org/10.1186/s12912-015-0119-1
_version_ 1782407919830040576
author Harb, Alain C.
Tarabay, Rami
Diab, Batoul
Ballout, Rami A.
Khamassi, Selma
Akl, Elie A.
author_facet Harb, Alain C.
Tarabay, Rami
Diab, Batoul
Ballout, Rami A.
Khamassi, Selma
Akl, Elie A.
author_sort Harb, Alain C.
collection PubMed
description BACKGROUND: Occupational sharps injuries are associated with transmission of bloodborne viruses to healthcare workers, including hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Similarly reuse of syringes in healthcare settings might transmit these infections between patients. The objective of this study was to systematically review the evidence about the effects of the use by health care workers of two types of safety engineered injection devices, when delivering intramuscular, subcutaneous, or intradermal injectable medications: sharps injury protection syringes and reuse prevention syringes. METHODS: We included both randomized and non-randomized studies comparing safety syringes to syringes without safety features. Outcomes of interest included needlestick injuries, and HIV, HBV and HCV infections amongst HCWs (for sharps injury prevention syringes) and patients (for reuse prevention syringes). When possible, we conducted meta-analyses using a random-effects model. We tested results for heterogeneity across studies using the I statistic. We assessed the quality of evidence by outcome using the GRADE methodology. RESULTS: We included nine eligible studies: six assessed devices that qualify as sharps injury prevention devices, and three assessed devices that qualify as both injury prevention devices and reuse prevention devices. Eight studies were observational while one was randomized. All studies assessed a single outcome: needle stick injuries among healthcare workers. For sharp injury prevention syringes, the meta-analysis of five studies resulted in a pooled relative risk of 0.54 [0.41, 0.71] for the effect on needlestick injuries per healthcare worker. The associated quality of evidence was rated as moderate. For reuse prevention syringes, data from one study provided a relative risk of 0.40 [0.27, 0.59] for the effect on needlestick injuries per healthcare worker. The associated quality of evidence was rated as moderate. We identified no studies reporting on the effect on the reuse of syringes. CONCLUSIONS: We identified moderate quality evidence that syringes with sharps injury prevention feature reduce the incidence of needlestick injuries per healthcare worker. We identified no studies reporting data for the remaining outcomes of interest for HCWs. Similarly we identified no studies reporting on the effect of syringes with a reuse prevention feature on the reuse of syringes or on the other outcomes of interest for patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12912-015-0119-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4697323
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-46973232016-01-01 Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis Harb, Alain C. Tarabay, Rami Diab, Batoul Ballout, Rami A. Khamassi, Selma Akl, Elie A. BMC Nurs Research Article BACKGROUND: Occupational sharps injuries are associated with transmission of bloodborne viruses to healthcare workers, including hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Similarly reuse of syringes in healthcare settings might transmit these infections between patients. The objective of this study was to systematically review the evidence about the effects of the use by health care workers of two types of safety engineered injection devices, when delivering intramuscular, subcutaneous, or intradermal injectable medications: sharps injury protection syringes and reuse prevention syringes. METHODS: We included both randomized and non-randomized studies comparing safety syringes to syringes without safety features. Outcomes of interest included needlestick injuries, and HIV, HBV and HCV infections amongst HCWs (for sharps injury prevention syringes) and patients (for reuse prevention syringes). When possible, we conducted meta-analyses using a random-effects model. We tested results for heterogeneity across studies using the I statistic. We assessed the quality of evidence by outcome using the GRADE methodology. RESULTS: We included nine eligible studies: six assessed devices that qualify as sharps injury prevention devices, and three assessed devices that qualify as both injury prevention devices and reuse prevention devices. Eight studies were observational while one was randomized. All studies assessed a single outcome: needle stick injuries among healthcare workers. For sharp injury prevention syringes, the meta-analysis of five studies resulted in a pooled relative risk of 0.54 [0.41, 0.71] for the effect on needlestick injuries per healthcare worker. The associated quality of evidence was rated as moderate. For reuse prevention syringes, data from one study provided a relative risk of 0.40 [0.27, 0.59] for the effect on needlestick injuries per healthcare worker. The associated quality of evidence was rated as moderate. We identified no studies reporting on the effect on the reuse of syringes. CONCLUSIONS: We identified moderate quality evidence that syringes with sharps injury prevention feature reduce the incidence of needlestick injuries per healthcare worker. We identified no studies reporting data for the remaining outcomes of interest for HCWs. Similarly we identified no studies reporting on the effect of syringes with a reuse prevention feature on the reuse of syringes or on the other outcomes of interest for patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12912-015-0119-1) contains supplementary material, which is available to authorized users. BioMed Central 2015-12-30 /pmc/articles/PMC4697323/ /pubmed/26722224 http://dx.doi.org/10.1186/s12912-015-0119-1 Text en © Harb et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Harb, Alain C.
Tarabay, Rami
Diab, Batoul
Ballout, Rami A.
Khamassi, Selma
Akl, Elie A.
Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
title Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
title_full Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
title_fullStr Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
title_full_unstemmed Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
title_short Safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
title_sort safety engineered injection devices for intramuscular, subcutaneous and intradermal injections in healthcare delivery settings: a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4697323/
https://www.ncbi.nlm.nih.gov/pubmed/26722224
http://dx.doi.org/10.1186/s12912-015-0119-1
work_keys_str_mv AT harbalainc safetyengineeredinjectiondevicesforintramuscularsubcutaneousandintradermalinjectionsinhealthcaredeliverysettingsasystematicreviewandmetaanalysis
AT tarabayrami safetyengineeredinjectiondevicesforintramuscularsubcutaneousandintradermalinjectionsinhealthcaredeliverysettingsasystematicreviewandmetaanalysis
AT diabbatoul safetyengineeredinjectiondevicesforintramuscularsubcutaneousandintradermalinjectionsinhealthcaredeliverysettingsasystematicreviewandmetaanalysis
AT balloutramia safetyengineeredinjectiondevicesforintramuscularsubcutaneousandintradermalinjectionsinhealthcaredeliverysettingsasystematicreviewandmetaanalysis
AT khamassiselma safetyengineeredinjectiondevicesforintramuscularsubcutaneousandintradermalinjectionsinhealthcaredeliverysettingsasystematicreviewandmetaanalysis
AT akleliea safetyengineeredinjectiondevicesforintramuscularsubcutaneousandintradermalinjectionsinhealthcaredeliverysettingsasystematicreviewandmetaanalysis