Cargando…

Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber

A new kind of hollow fiber surface plasmon resonance sensor (HF-SPRS) based on the silver-coated ethylene tetra-fluoro-ethylene (ETFE) hollow fiber (HF) is presented. The ETFE HF-SPRS is fabricated, and its performance is investigated experimentally by measuring the transmission spectra of the senso...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Pan, He, Yu-Jing, Zhu, Xiao-Song, Shi, Yi-Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4701261/
https://www.ncbi.nlm.nih.gov/pubmed/26540062
http://dx.doi.org/10.3390/s151127917
_version_ 1782408446648254464
author Chen, Pan
He, Yu-Jing
Zhu, Xiao-Song
Shi, Yi-Wei
author_facet Chen, Pan
He, Yu-Jing
Zhu, Xiao-Song
Shi, Yi-Wei
author_sort Chen, Pan
collection PubMed
description A new kind of hollow fiber surface plasmon resonance sensor (HF-SPRS) based on the silver-coated ethylene tetra-fluoro-ethylene (ETFE) hollow fiber (HF) is presented. The ETFE HF-SPRS is fabricated, and its performance is investigated experimentally by measuring the transmission spectra of the sensor when filled by liquid sensed media with different refractive indices (RIs). Theoretical analysis based on the ray transmission model is also taken to evaluate the sensor. Because the RI of ETFE is much lower than that of fused silica (FSG), the ETFE HF-SPRS can extend the lower limit of the detection range of the early reported FSG HF-SPRS from 1.5 to 1.42 approximately. This could greatly enhance the application potential of HF-SPRS. Moreover, the joint use of both ETFE and FSG HF-SPRSs can cover a wide detection range from 1.42 to 1.69 approximately with high sensitivities larger than 1000 nm/RIU.
format Online
Article
Text
id pubmed-4701261
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-47012612016-01-19 Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber Chen, Pan He, Yu-Jing Zhu, Xiao-Song Shi, Yi-Wei Sensors (Basel) Article A new kind of hollow fiber surface plasmon resonance sensor (HF-SPRS) based on the silver-coated ethylene tetra-fluoro-ethylene (ETFE) hollow fiber (HF) is presented. The ETFE HF-SPRS is fabricated, and its performance is investigated experimentally by measuring the transmission spectra of the sensor when filled by liquid sensed media with different refractive indices (RIs). Theoretical analysis based on the ray transmission model is also taken to evaluate the sensor. Because the RI of ETFE is much lower than that of fused silica (FSG), the ETFE HF-SPRS can extend the lower limit of the detection range of the early reported FSG HF-SPRS from 1.5 to 1.42 approximately. This could greatly enhance the application potential of HF-SPRS. Moreover, the joint use of both ETFE and FSG HF-SPRSs can cover a wide detection range from 1.42 to 1.69 approximately with high sensitivities larger than 1000 nm/RIU. MDPI 2015-11-03 /pmc/articles/PMC4701261/ /pubmed/26540062 http://dx.doi.org/10.3390/s151127917 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Pan
He, Yu-Jing
Zhu, Xiao-Song
Shi, Yi-Wei
Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber
title Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber
title_full Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber
title_fullStr Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber
title_full_unstemmed Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber
title_short Surface Plasmon Resonance Sensor Based on Ethylene Tetra-Fluoro-Ethylene Hollow Fiber
title_sort surface plasmon resonance sensor based on ethylene tetra-fluoro-ethylene hollow fiber
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4701261/
https://www.ncbi.nlm.nih.gov/pubmed/26540062
http://dx.doi.org/10.3390/s151127917
work_keys_str_mv AT chenpan surfaceplasmonresonancesensorbasedonethylenetetrafluoroethylenehollowfiber
AT heyujing surfaceplasmonresonancesensorbasedonethylenetetrafluoroethylenehollowfiber
AT zhuxiaosong surfaceplasmonresonancesensorbasedonethylenetetrafluoroethylenehollowfiber
AT shiyiwei surfaceplasmonresonancesensorbasedonethylenetetrafluoroethylenehollowfiber