Cargando…

Quantitative Ethylene Measurements with MOx Chemiresistive Sensors at Different Relative Air Humidities

The sensitivity of two commercial metal oxide (MOx) sensors to ethylene is tested at different relative humidities. One sensor (MiCS-5914) is based on tungsten oxide, the other (MQ-3) on tin oxide. Both sensors were found to be sensitive to ethylene concentrations down to 10 ppm. Both sensors have s...

Descripción completa

Detalles Bibliográficos
Autores principales: Krivec, Matic, Mc Gunnigle, Gerald, Abram, Anže, Maier, Dieter, Waldner, Roland, Gostner, Johanna M., Überall, Florian, Leitner, Raimund
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4701270/
https://www.ncbi.nlm.nih.gov/pubmed/26561812
http://dx.doi.org/10.3390/s151128088
Descripción
Sumario:The sensitivity of two commercial metal oxide (MOx) sensors to ethylene is tested at different relative humidities. One sensor (MiCS-5914) is based on tungsten oxide, the other (MQ-3) on tin oxide. Both sensors were found to be sensitive to ethylene concentrations down to 10 ppm. Both sensors have significant response times; however, the tungsten sensor is the faster one. Sensor models are developed that predict the concentration of ethylene given the sensor output and the relative humidity. The MQ-3 sensor model achieves an accuracy of ±9.2 ppm and the MiCS-5914 sensor model predicts concentration to ±7.0 ppm. Both sensors are more accurate for concentrations below 50 ppm, achieving ±6.7 ppm (MQ-3) and 5.7 ppm (MiCS-5914).