Cargando…

Extension of the standard addition method by blank addition

Standard addition involves adding varying amounts of the analyte to sample portions of fixed mass or fixed volume and submitting those portions to the sample preparation procedure. After measuring the final extract solutions, the observed signals are linearly regressed on the spiked amounts. The ori...

Descripción completa

Detalles Bibliográficos
Autor principal: Steliopoulos, Panagiotis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4703584/
https://www.ncbi.nlm.nih.gov/pubmed/26844210
http://dx.doi.org/10.1016/j.mex.2015.09.001
_version_ 1782408747870584832
author Steliopoulos, Panagiotis
author_facet Steliopoulos, Panagiotis
author_sort Steliopoulos, Panagiotis
collection PubMed
description Standard addition involves adding varying amounts of the analyte to sample portions of fixed mass or fixed volume and submitting those portions to the sample preparation procedure. After measuring the final extract solutions, the observed signals are linearly regressed on the spiked amounts. The original unknown amount is estimated by the opposite of the abscissa intercept of the fitted straight line [1]. A limitation of this method is that only data points with abscissa values equal to and greater than zero are available so that there is no information on whether linearity holds below the spiking level zero. An approach to overcome this limitation is introduced. • Standard addition is combined with blank addition. • Blank addition means that defined mixtures of blank matrix and sample material are subjected to sample preparation to give final extract solutions. • Equations are presented to estimate the original unknown amount and to calculate the 1-2α confidence interval about this estimate using the combined data set.
format Online
Article
Text
id pubmed-4703584
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-47035842016-02-03 Extension of the standard addition method by blank addition Steliopoulos, Panagiotis MethodsX Chemistry Standard addition involves adding varying amounts of the analyte to sample portions of fixed mass or fixed volume and submitting those portions to the sample preparation procedure. After measuring the final extract solutions, the observed signals are linearly regressed on the spiked amounts. The original unknown amount is estimated by the opposite of the abscissa intercept of the fitted straight line [1]. A limitation of this method is that only data points with abscissa values equal to and greater than zero are available so that there is no information on whether linearity holds below the spiking level zero. An approach to overcome this limitation is introduced. • Standard addition is combined with blank addition. • Blank addition means that defined mixtures of blank matrix and sample material are subjected to sample preparation to give final extract solutions. • Equations are presented to estimate the original unknown amount and to calculate the 1-2α confidence interval about this estimate using the combined data set. Elsevier 2015-09-09 /pmc/articles/PMC4703584/ /pubmed/26844210 http://dx.doi.org/10.1016/j.mex.2015.09.001 Text en © 2015 The Author http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Chemistry
Steliopoulos, Panagiotis
Extension of the standard addition method by blank addition
title Extension of the standard addition method by blank addition
title_full Extension of the standard addition method by blank addition
title_fullStr Extension of the standard addition method by blank addition
title_full_unstemmed Extension of the standard addition method by blank addition
title_short Extension of the standard addition method by blank addition
title_sort extension of the standard addition method by blank addition
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4703584/
https://www.ncbi.nlm.nih.gov/pubmed/26844210
http://dx.doi.org/10.1016/j.mex.2015.09.001
work_keys_str_mv AT steliopoulospanagiotis extensionofthestandardadditionmethodbyblankaddition