Cargando…

Yes, one can obtain better quality structures from routine X-ray data collection

Single-crystal X-ray diffraction structural results for benzidine dihydrochloride, hydrated and protonated N,N,N,N-peri(dimethylamino)naphthalene chloride, triptycene, dichlorodimethyltriptycene and decamethylferrocene have been analysed. A critical discussion of the dependence of structural and the...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanjuan-Szklarz, W. Fabiola, Hoser, Anna A., Gutmann, Matthias, Madsen, Anders Østergaard, Woźniak, Krzysztof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4704080/
https://www.ncbi.nlm.nih.gov/pubmed/26870382
http://dx.doi.org/10.1107/S2052252515020941
_version_ 1782408838782124032
author Sanjuan-Szklarz, W. Fabiola
Hoser, Anna A.
Gutmann, Matthias
Madsen, Anders Østergaard
Woźniak, Krzysztof
author_facet Sanjuan-Szklarz, W. Fabiola
Hoser, Anna A.
Gutmann, Matthias
Madsen, Anders Østergaard
Woźniak, Krzysztof
author_sort Sanjuan-Szklarz, W. Fabiola
collection PubMed
description Single-crystal X-ray diffraction structural results for benzidine dihydrochloride, hydrated and protonated N,N,N,N-peri(dimethylamino)naphthalene chloride, triptycene, dichlorodimethyltriptycene and decamethylferrocene have been analysed. A critical discussion of the dependence of structural and thermal parameters on resolution for these compounds is presented. Results of refinements against X-ray data, cut off to different resolutions from the high-resolution data files, are compared to structural models derived from neutron diffraction experiments. The Independent Atom Model (IAM) and the Transferable Aspherical Atom Model (TAAM) are tested. The average differences between the X-ray and neutron structural parameters (with the exception of valence angles defined by H atoms) decrease with the increasing 2θ(max) angle. The scale of differences between X-ray and neutron geometrical parameters can be significantly reduced when data are collected to the higher, than commonly used, 2θ(max) diffraction angles (for Mo Kα 2θ(max) > 65°). The final structural and thermal parameters obtained for the studied compounds using TAAM refinement are in better agreement with the neutron values than the IAM results for all resolutions and all compounds. By using TAAM, it is still possible to obtain accurate results even from low-resolution X-ray data. This is particularly important as TAAM is easy to apply and can routinely be used to improve the quality of structural investigations [Dominiak (2015 ▸). LSDB from UBDB. University of Buffalo, USA]. We can recommend that, in order to obtain more adequate (more accurate and precise) structural and displacement parameters during the IAM model refinement, data should be collected up to the larger diffraction angles, at least, for Mo Kα radiation to 2θ(max) = 65° (sin θ(max)/λ < 0.75 Å(−1)). The TAAM approach is a very good option to obtain more adequate results even using data collected to the lower 2θ(max) angles. Also the results of translation–libration–screw (TLS) analysis and vibrational entropy values are more reliable for 2θ(max) > 65°.
format Online
Article
Text
id pubmed-4704080
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-47040802016-02-11 Yes, one can obtain better quality structures from routine X-ray data collection Sanjuan-Szklarz, W. Fabiola Hoser, Anna A. Gutmann, Matthias Madsen, Anders Østergaard Woźniak, Krzysztof IUCrJ Research Papers Single-crystal X-ray diffraction structural results for benzidine dihydrochloride, hydrated and protonated N,N,N,N-peri(dimethylamino)naphthalene chloride, triptycene, dichlorodimethyltriptycene and decamethylferrocene have been analysed. A critical discussion of the dependence of structural and thermal parameters on resolution for these compounds is presented. Results of refinements against X-ray data, cut off to different resolutions from the high-resolution data files, are compared to structural models derived from neutron diffraction experiments. The Independent Atom Model (IAM) and the Transferable Aspherical Atom Model (TAAM) are tested. The average differences between the X-ray and neutron structural parameters (with the exception of valence angles defined by H atoms) decrease with the increasing 2θ(max) angle. The scale of differences between X-ray and neutron geometrical parameters can be significantly reduced when data are collected to the higher, than commonly used, 2θ(max) diffraction angles (for Mo Kα 2θ(max) > 65°). The final structural and thermal parameters obtained for the studied compounds using TAAM refinement are in better agreement with the neutron values than the IAM results for all resolutions and all compounds. By using TAAM, it is still possible to obtain accurate results even from low-resolution X-ray data. This is particularly important as TAAM is easy to apply and can routinely be used to improve the quality of structural investigations [Dominiak (2015 ▸). LSDB from UBDB. University of Buffalo, USA]. We can recommend that, in order to obtain more adequate (more accurate and precise) structural and displacement parameters during the IAM model refinement, data should be collected up to the larger diffraction angles, at least, for Mo Kα radiation to 2θ(max) = 65° (sin θ(max)/λ < 0.75 Å(−1)). The TAAM approach is a very good option to obtain more adequate results even using data collected to the lower 2θ(max) angles. Also the results of translation–libration–screw (TLS) analysis and vibrational entropy values are more reliable for 2θ(max) > 65°. International Union of Crystallography 2016-01-01 /pmc/articles/PMC4704080/ /pubmed/26870382 http://dx.doi.org/10.1107/S2052252515020941 Text en © W. Fabiola Sanjuan-Szklarz et al. 2016 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Sanjuan-Szklarz, W. Fabiola
Hoser, Anna A.
Gutmann, Matthias
Madsen, Anders Østergaard
Woźniak, Krzysztof
Yes, one can obtain better quality structures from routine X-ray data collection
title Yes, one can obtain better quality structures from routine X-ray data collection
title_full Yes, one can obtain better quality structures from routine X-ray data collection
title_fullStr Yes, one can obtain better quality structures from routine X-ray data collection
title_full_unstemmed Yes, one can obtain better quality structures from routine X-ray data collection
title_short Yes, one can obtain better quality structures from routine X-ray data collection
title_sort yes, one can obtain better quality structures from routine x-ray data collection
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4704080/
https://www.ncbi.nlm.nih.gov/pubmed/26870382
http://dx.doi.org/10.1107/S2052252515020941
work_keys_str_mv AT sanjuanszklarzwfabiola yesonecanobtainbetterqualitystructuresfromroutinexraydatacollection
AT hoserannaa yesonecanobtainbetterqualitystructuresfromroutinexraydatacollection
AT gutmannmatthias yesonecanobtainbetterqualitystructuresfromroutinexraydatacollection
AT madsenandersøstergaard yesonecanobtainbetterqualitystructuresfromroutinexraydatacollection
AT wozniakkrzysztof yesonecanobtainbetterqualitystructuresfromroutinexraydatacollection