Cargando…
Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
Endovascular aneurysm repair has been associated with changes in arterial stiffness, as estimated by pulse wave velocity (PWV). This marker is influenced by the medical status of the patient, the elastic characteristics of the aneurysm wall, and the presence of intraluminal thrombus. Therefore, in o...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707224/ https://www.ncbi.nlm.nih.gov/pubmed/26793712 http://dx.doi.org/10.3389/fsurg.2015.00068 |
_version_ | 1782409269376712704 |
---|---|
author | Georgakarakos, Efstratios Argyriou, Christos Georgiadis, George S. Lazarides, Miltos K. |
author_facet | Georgakarakos, Efstratios Argyriou, Christos Georgiadis, George S. Lazarides, Miltos K. |
author_sort | Georgakarakos, Efstratios |
collection | PubMed |
description | Endovascular aneurysm repair has been associated with changes in arterial stiffness, as estimated by pulse wave velocity (PWV). This marker is influenced by the medical status of the patient, the elastic characteristics of the aneurysm wall, and the presence of intraluminal thrombus. Therefore, in order to delineate the influence of the endograft implantation in the early post-operative period, we conducted non-invasively pulse wave analysis in a male patient with an abdominal aortic aneurysm containing no intraluminal thrombus, unremarkable past medical history, and absence of peripheral arterial disease. The estimated parameters were the systolic and diastolic pressure calculated at the aortic level (central pressures), PWV, augmentation pressure (AP) and augmentation index (AI), pressure wave reflection magnitude (RM), and peripheral resistance. Central systolic and diastolic pressure decreased post-operatively. PWV showed subtle changes from 11.6 to 10.6 and 10.9 m/s at 1-week and 1-month, respectively. Accordingly, the AI decreased from 28 to 14% and continued to drop to 25%. The AP decreased gradually from 15 to 6 and 4 mmHg. The wave RM dropped from 68 to 52% at 1-month. Finally, the peripheral resistance dropped from 1.41 to 0.99 and 0.85 dyn × s × cm(−5). Our example shows that the implantation of an aortic endograft can modify the pressure wave reflection over the aortic bifurcation without causing significant alterations in PWV. |
format | Online Article Text |
id | pubmed-4707224 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-47072242016-01-20 Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft Georgakarakos, Efstratios Argyriou, Christos Georgiadis, George S. Lazarides, Miltos K. Front Surg Surgery Endovascular aneurysm repair has been associated with changes in arterial stiffness, as estimated by pulse wave velocity (PWV). This marker is influenced by the medical status of the patient, the elastic characteristics of the aneurysm wall, and the presence of intraluminal thrombus. Therefore, in order to delineate the influence of the endograft implantation in the early post-operative period, we conducted non-invasively pulse wave analysis in a male patient with an abdominal aortic aneurysm containing no intraluminal thrombus, unremarkable past medical history, and absence of peripheral arterial disease. The estimated parameters were the systolic and diastolic pressure calculated at the aortic level (central pressures), PWV, augmentation pressure (AP) and augmentation index (AI), pressure wave reflection magnitude (RM), and peripheral resistance. Central systolic and diastolic pressure decreased post-operatively. PWV showed subtle changes from 11.6 to 10.6 and 10.9 m/s at 1-week and 1-month, respectively. Accordingly, the AI decreased from 28 to 14% and continued to drop to 25%. The AP decreased gradually from 15 to 6 and 4 mmHg. The wave RM dropped from 68 to 52% at 1-month. Finally, the peripheral resistance dropped from 1.41 to 0.99 and 0.85 dyn × s × cm(−5). Our example shows that the implantation of an aortic endograft can modify the pressure wave reflection over the aortic bifurcation without causing significant alterations in PWV. Frontiers Media S.A. 2016-01-11 /pmc/articles/PMC4707224/ /pubmed/26793712 http://dx.doi.org/10.3389/fsurg.2015.00068 Text en Copyright © 2016 Georgakarakos, Argyriou, Georgiadis and Lazarides. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Georgakarakos, Efstratios Argyriou, Christos Georgiadis, George S. Lazarides, Miltos K. Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft |
title | Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft |
title_full | Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft |
title_fullStr | Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft |
title_full_unstemmed | Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft |
title_short | Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft |
title_sort | non-invasive pulse wave analysis in a thrombus-free abdominal aortic aneurysm after implantation of a nitinol aortic endograft |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707224/ https://www.ncbi.nlm.nih.gov/pubmed/26793712 http://dx.doi.org/10.3389/fsurg.2015.00068 |
work_keys_str_mv | AT georgakarakosefstratios noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft AT argyriouchristos noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft AT georgiadisgeorges noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft AT lazaridesmiltosk noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft |