Cargando…

Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft

Endovascular aneurysm repair has been associated with changes in arterial stiffness, as estimated by pulse wave velocity (PWV). This marker is influenced by the medical status of the patient, the elastic characteristics of the aneurysm wall, and the presence of intraluminal thrombus. Therefore, in o...

Descripción completa

Detalles Bibliográficos
Autores principales: Georgakarakos, Efstratios, Argyriou, Christos, Georgiadis, George S., Lazarides, Miltos K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707224/
https://www.ncbi.nlm.nih.gov/pubmed/26793712
http://dx.doi.org/10.3389/fsurg.2015.00068
_version_ 1782409269376712704
author Georgakarakos, Efstratios
Argyriou, Christos
Georgiadis, George S.
Lazarides, Miltos K.
author_facet Georgakarakos, Efstratios
Argyriou, Christos
Georgiadis, George S.
Lazarides, Miltos K.
author_sort Georgakarakos, Efstratios
collection PubMed
description Endovascular aneurysm repair has been associated with changes in arterial stiffness, as estimated by pulse wave velocity (PWV). This marker is influenced by the medical status of the patient, the elastic characteristics of the aneurysm wall, and the presence of intraluminal thrombus. Therefore, in order to delineate the influence of the endograft implantation in the early post-operative period, we conducted non-invasively pulse wave analysis in a male patient with an abdominal aortic aneurysm containing no intraluminal thrombus, unremarkable past medical history, and absence of peripheral arterial disease. The estimated parameters were the systolic and diastolic pressure calculated at the aortic level (central pressures), PWV, augmentation pressure (AP) and augmentation index (AI), pressure wave reflection magnitude (RM), and peripheral resistance. Central systolic and diastolic pressure decreased post-operatively. PWV showed subtle changes from 11.6 to 10.6 and 10.9 m/s at 1-week and 1-month, respectively. Accordingly, the AI decreased from 28 to 14% and continued to drop to 25%. The AP decreased gradually from 15 to 6 and 4 mmHg. The wave RM dropped from 68 to 52% at 1-month. Finally, the peripheral resistance dropped from 1.41 to 0.99 and 0.85 dyn × s × cm(−5). Our example shows that the implantation of an aortic endograft can modify the pressure wave reflection over the aortic bifurcation without causing significant alterations in PWV.
format Online
Article
Text
id pubmed-4707224
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-47072242016-01-20 Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft Georgakarakos, Efstratios Argyriou, Christos Georgiadis, George S. Lazarides, Miltos K. Front Surg Surgery Endovascular aneurysm repair has been associated with changes in arterial stiffness, as estimated by pulse wave velocity (PWV). This marker is influenced by the medical status of the patient, the elastic characteristics of the aneurysm wall, and the presence of intraluminal thrombus. Therefore, in order to delineate the influence of the endograft implantation in the early post-operative period, we conducted non-invasively pulse wave analysis in a male patient with an abdominal aortic aneurysm containing no intraluminal thrombus, unremarkable past medical history, and absence of peripheral arterial disease. The estimated parameters were the systolic and diastolic pressure calculated at the aortic level (central pressures), PWV, augmentation pressure (AP) and augmentation index (AI), pressure wave reflection magnitude (RM), and peripheral resistance. Central systolic and diastolic pressure decreased post-operatively. PWV showed subtle changes from 11.6 to 10.6 and 10.9 m/s at 1-week and 1-month, respectively. Accordingly, the AI decreased from 28 to 14% and continued to drop to 25%. The AP decreased gradually from 15 to 6 and 4 mmHg. The wave RM dropped from 68 to 52% at 1-month. Finally, the peripheral resistance dropped from 1.41 to 0.99 and 0.85 dyn × s × cm(−5). Our example shows that the implantation of an aortic endograft can modify the pressure wave reflection over the aortic bifurcation without causing significant alterations in PWV. Frontiers Media S.A. 2016-01-11 /pmc/articles/PMC4707224/ /pubmed/26793712 http://dx.doi.org/10.3389/fsurg.2015.00068 Text en Copyright © 2016 Georgakarakos, Argyriou, Georgiadis and Lazarides. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Georgakarakos, Efstratios
Argyriou, Christos
Georgiadis, George S.
Lazarides, Miltos K.
Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
title Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
title_full Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
title_fullStr Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
title_full_unstemmed Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
title_short Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft
title_sort non-invasive pulse wave analysis in a thrombus-free abdominal aortic aneurysm after implantation of a nitinol aortic endograft
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707224/
https://www.ncbi.nlm.nih.gov/pubmed/26793712
http://dx.doi.org/10.3389/fsurg.2015.00068
work_keys_str_mv AT georgakarakosefstratios noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft
AT argyriouchristos noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft
AT georgiadisgeorges noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft
AT lazaridesmiltosk noninvasivepulsewaveanalysisinathrombusfreeabdominalaorticaneurysmafterimplantationofanitinolaorticendograft