Cargando…
Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE) and double-balloon enteroscopy (DBE) for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The char...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707381/ https://www.ncbi.nlm.nih.gov/pubmed/26962305 http://dx.doi.org/10.1155/2016/5172873 |
_version_ | 1782409303012933632 |
---|---|
author | Wang, Jingjing Guo, Qiaozhen Zhao, Jianping Liu, Mei Liao, Guangquan Chen, Nianjun Tian, Dean Wu, Xiaoli |
author_facet | Wang, Jingjing Guo, Qiaozhen Zhao, Jianping Liu, Mei Liao, Guangquan Chen, Nianjun Tian, Dean Wu, Xiaoli |
author_sort | Wang, Jingjing |
collection | PubMed |
description | Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE) and double-balloon enteroscopy (DBE) for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The characteristics of the patients, detection rates, diagnostic yields, sensitivity, specificity, positive predictive value, and negative predictive value were described and analyzed. Results. The overall detection rates of DBE and MDCTE were 92.6% and 55.8%, respectively (P<0.05), while the overall diagnostic yields were 83.2% and 33.7%, respectively (P<0.05). The sensitivity, specificity, positive predictive value, and negative predictive value of DBE were all higher than those of MDCTE. DBE had a higher diagnostic yield for OGIB (87.3% versus 20.9%, P<0.05). The diagnostic yields of DBE were higher than those of MDCTE for inflammatory diseases, angioma/angiodysplasia, and diverticulums, while being not for gastrointestinal tumors/polyps. Conclusions. The diagnostic value of DBE for small bowel diseases is better than that of MDCTE as a whole, but if gastrointestinal tumors are suspected, MDCTE is also needed to gain a comprehensive and accurate diagnosis. |
format | Online Article Text |
id | pubmed-4707381 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47073812016-03-09 Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases Wang, Jingjing Guo, Qiaozhen Zhao, Jianping Liu, Mei Liao, Guangquan Chen, Nianjun Tian, Dean Wu, Xiaoli Gastroenterol Res Pract Clinical Study Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE) and double-balloon enteroscopy (DBE) for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The characteristics of the patients, detection rates, diagnostic yields, sensitivity, specificity, positive predictive value, and negative predictive value were described and analyzed. Results. The overall detection rates of DBE and MDCTE were 92.6% and 55.8%, respectively (P<0.05), while the overall diagnostic yields were 83.2% and 33.7%, respectively (P<0.05). The sensitivity, specificity, positive predictive value, and negative predictive value of DBE were all higher than those of MDCTE. DBE had a higher diagnostic yield for OGIB (87.3% versus 20.9%, P<0.05). The diagnostic yields of DBE were higher than those of MDCTE for inflammatory diseases, angioma/angiodysplasia, and diverticulums, while being not for gastrointestinal tumors/polyps. Conclusions. The diagnostic value of DBE for small bowel diseases is better than that of MDCTE as a whole, but if gastrointestinal tumors are suspected, MDCTE is also needed to gain a comprehensive and accurate diagnosis. Hindawi Publishing Corporation 2016 2015-12-28 /pmc/articles/PMC4707381/ /pubmed/26962305 http://dx.doi.org/10.1155/2016/5172873 Text en Copyright © 2016 Jingjing Wang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Wang, Jingjing Guo, Qiaozhen Zhao, Jianping Liu, Mei Liao, Guangquan Chen, Nianjun Tian, Dean Wu, Xiaoli Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases |
title | Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases |
title_full | Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases |
title_fullStr | Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases |
title_full_unstemmed | Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases |
title_short | Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases |
title_sort | multidetector ct enterography versus double-balloon enteroscopy: comparison of the diagnostic value for patients with suspected small bowel diseases |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707381/ https://www.ncbi.nlm.nih.gov/pubmed/26962305 http://dx.doi.org/10.1155/2016/5172873 |
work_keys_str_mv | AT wangjingjing multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT guoqiaozhen multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT zhaojianping multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT liumei multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT liaoguangquan multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT chennianjun multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT tiandean multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases AT wuxiaoli multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases |