Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases

Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE) and double-balloon enteroscopy (DBE) for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The char...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jingjing, Guo, Qiaozhen, Zhao, Jianping, Liu, Mei, Liao, Guangquan, Chen, Nianjun, Tian, Dean, Wu, Xiaoli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707381/
https://www.ncbi.nlm.nih.gov/pubmed/26962305
http://dx.doi.org/10.1155/2016/5172873
_version_ 1782409303012933632
author Wang, Jingjing
Guo, Qiaozhen
Zhao, Jianping
Liu, Mei
Liao, Guangquan
Chen, Nianjun
Tian, Dean
Wu, Xiaoli
author_facet Wang, Jingjing
Guo, Qiaozhen
Zhao, Jianping
Liu, Mei
Liao, Guangquan
Chen, Nianjun
Tian, Dean
Wu, Xiaoli
author_sort Wang, Jingjing
collection PubMed
description Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE) and double-balloon enteroscopy (DBE) for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The characteristics of the patients, detection rates, diagnostic yields, sensitivity, specificity, positive predictive value, and negative predictive value were described and analyzed. Results. The overall detection rates of DBE and MDCTE were 92.6% and 55.8%, respectively (P<0.05), while the overall diagnostic yields were 83.2% and 33.7%, respectively (P<0.05). The sensitivity, specificity, positive predictive value, and negative predictive value of DBE were all higher than those of MDCTE. DBE had a higher diagnostic yield for OGIB (87.3% versus 20.9%, P<0.05). The diagnostic yields of DBE were higher than those of MDCTE for inflammatory diseases, angioma/angiodysplasia, and diverticulums, while being not for gastrointestinal tumors/polyps. Conclusions. The diagnostic value of DBE for small bowel diseases is better than that of MDCTE as a whole, but if gastrointestinal tumors are suspected, MDCTE is also needed to gain a comprehensive and accurate diagnosis.
format Online
Article
Text
id pubmed-4707381
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-47073812016-03-09 Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases Wang, Jingjing Guo, Qiaozhen Zhao, Jianping Liu, Mei Liao, Guangquan Chen, Nianjun Tian, Dean Wu, Xiaoli Gastroenterol Res Pract Clinical Study Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE) and double-balloon enteroscopy (DBE) for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The characteristics of the patients, detection rates, diagnostic yields, sensitivity, specificity, positive predictive value, and negative predictive value were described and analyzed. Results. The overall detection rates of DBE and MDCTE were 92.6% and 55.8%, respectively (P<0.05), while the overall diagnostic yields were 83.2% and 33.7%, respectively (P<0.05). The sensitivity, specificity, positive predictive value, and negative predictive value of DBE were all higher than those of MDCTE. DBE had a higher diagnostic yield for OGIB (87.3% versus 20.9%, P<0.05). The diagnostic yields of DBE were higher than those of MDCTE for inflammatory diseases, angioma/angiodysplasia, and diverticulums, while being not for gastrointestinal tumors/polyps. Conclusions. The diagnostic value of DBE for small bowel diseases is better than that of MDCTE as a whole, but if gastrointestinal tumors are suspected, MDCTE is also needed to gain a comprehensive and accurate diagnosis. Hindawi Publishing Corporation 2016 2015-12-28 /pmc/articles/PMC4707381/ /pubmed/26962305 http://dx.doi.org/10.1155/2016/5172873 Text en Copyright © 2016 Jingjing Wang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Wang, Jingjing
Guo, Qiaozhen
Zhao, Jianping
Liu, Mei
Liao, Guangquan
Chen, Nianjun
Tian, Dean
Wu, Xiaoli
Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
title Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
title_full Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
title_fullStr Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
title_full_unstemmed Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
title_short Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases
title_sort multidetector ct enterography versus double-balloon enteroscopy: comparison of the diagnostic value for patients with suspected small bowel diseases
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4707381/
https://www.ncbi.nlm.nih.gov/pubmed/26962305
http://dx.doi.org/10.1155/2016/5172873
work_keys_str_mv AT wangjingjing multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT guoqiaozhen multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT zhaojianping multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT liumei multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT liaoguangquan multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT chennianjun multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT tiandean multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases
AT wuxiaoli multidetectorctenterographyversusdoubleballoonenteroscopycomparisonofthediagnosticvalueforpatientswithsuspectedsmallboweldiseases