MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane

Analysis of (34)S/(32)S of sulfate in rainwater and soil solutions can be seen as a powerful tool for the study of the sulfur cycle. Therefore, it is considered as a useful means, e.g., for amelioration and calibration of ecological or biogeochemical models. Due to several analytical limitations, ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanousek, Ondrej, Berger, Torsten W., Prohaska, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4709390/
https://www.ncbi.nlm.nih.gov/pubmed/26438477
http://dx.doi.org/10.1007/s00216-015-9053-z
_version_ 1782409632417841152
author Hanousek, Ondrej
Berger, Torsten W.
Prohaska, Thomas
author_facet Hanousek, Ondrej
Berger, Torsten W.
Prohaska, Thomas
author_sort Hanousek, Ondrej
collection PubMed
description Analysis of (34)S/(32)S of sulfate in rainwater and soil solutions can be seen as a powerful tool for the study of the sulfur cycle. Therefore, it is considered as a useful means, e.g., for amelioration and calibration of ecological or biogeochemical models. Due to several analytical limitations, mainly caused by low sulfate concentration in rainwater, complex matrix of soil solutions, limited sample volume, and high number of samples in ecosystem studies, a straightforward analytical protocol is required to provide accurate S isotopic data on a large set of diverse samples. Therefore, sulfate separation by anion exchange membrane was combined with precise isotopic measurement by multicollector inductively coupled plasma mass spectrometry (MC ICP-MS). The separation method proved to be able to remove quantitatively sulfate from matrix cations (Ca, K, Na, or Li) which is a precondition in order to avoid a matrix-induced analytical bias in the mass spectrometer. Moreover, sulfate exchange on the resin is capable of preconcentrating sulfate from low concentrated solutions (to factor 3 in our protocol). No significant sulfur isotope fractionation was observed during separation and preconcentration. MC ICP-MS operated at edge mass resolution has enabled the direct (34)S/(32)S analysis of sulfate eluted from the membrane, with an expanded uncertainty U (k = 2) down to 0.3 ‰ (a single measurement). The protocol was optimized and validated using different sulfate solutions and different matrix compositions. The optimized method was applied in a study on solute samples retrieved in a beech (Fagus sylvatica) forest in the Vienna Woods. Both rainwater (precipitation and tree throughfall) and soil solution δ(34)S(VCDT) ranged between 4 and 6 ‰, the ratio in soil solution being slightly lower. The lower ratio indicates that a considerable portion of the atmospherically deposited sulfate is cycled through the organic S pool before being released to the soil solution. Nearly the same trends and variations were observed in soil solution and rainwater δ(34)S(VCDT) values showing that sulfate adsorption/desorption are not important processes in the studied soil. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-015-9053-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4709390
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-47093902016-01-18 MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane Hanousek, Ondrej Berger, Torsten W. Prohaska, Thomas Anal Bioanal Chem Research Paper Analysis of (34)S/(32)S of sulfate in rainwater and soil solutions can be seen as a powerful tool for the study of the sulfur cycle. Therefore, it is considered as a useful means, e.g., for amelioration and calibration of ecological or biogeochemical models. Due to several analytical limitations, mainly caused by low sulfate concentration in rainwater, complex matrix of soil solutions, limited sample volume, and high number of samples in ecosystem studies, a straightforward analytical protocol is required to provide accurate S isotopic data on a large set of diverse samples. Therefore, sulfate separation by anion exchange membrane was combined with precise isotopic measurement by multicollector inductively coupled plasma mass spectrometry (MC ICP-MS). The separation method proved to be able to remove quantitatively sulfate from matrix cations (Ca, K, Na, or Li) which is a precondition in order to avoid a matrix-induced analytical bias in the mass spectrometer. Moreover, sulfate exchange on the resin is capable of preconcentrating sulfate from low concentrated solutions (to factor 3 in our protocol). No significant sulfur isotope fractionation was observed during separation and preconcentration. MC ICP-MS operated at edge mass resolution has enabled the direct (34)S/(32)S analysis of sulfate eluted from the membrane, with an expanded uncertainty U (k = 2) down to 0.3 ‰ (a single measurement). The protocol was optimized and validated using different sulfate solutions and different matrix compositions. The optimized method was applied in a study on solute samples retrieved in a beech (Fagus sylvatica) forest in the Vienna Woods. Both rainwater (precipitation and tree throughfall) and soil solution δ(34)S(VCDT) ranged between 4 and 6 ‰, the ratio in soil solution being slightly lower. The lower ratio indicates that a considerable portion of the atmospherically deposited sulfate is cycled through the organic S pool before being released to the soil solution. Nearly the same trends and variations were observed in soil solution and rainwater δ(34)S(VCDT) values showing that sulfate adsorption/desorption are not important processes in the studied soil. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00216-015-9053-z) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2015-10-05 2016 /pmc/articles/PMC4709390/ /pubmed/26438477 http://dx.doi.org/10.1007/s00216-015-9053-z Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research Paper
Hanousek, Ondrej
Berger, Torsten W.
Prohaska, Thomas
MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
title MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
title_full MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
title_fullStr MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
title_full_unstemmed MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
title_short MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
title_sort mc icp-ms δ(34)s(vcdt) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4709390/
https://www.ncbi.nlm.nih.gov/pubmed/26438477
http://dx.doi.org/10.1007/s00216-015-9053-z
work_keys_str_mv AT hanousekondrej mcicpmsd34svcdtmeasurementofdissolvedsulfateinenvironmentalaqueoussamplesaftermatrixseparationbymeansofananionexchangemembrane
AT bergertorstenw mcicpmsd34svcdtmeasurementofdissolvedsulfateinenvironmentalaqueoussamplesaftermatrixseparationbymeansofananionexchangemembrane
AT prohaskathomas mcicpmsd34svcdtmeasurementofdissolvedsulfateinenvironmentalaqueoussamplesaftermatrixseparationbymeansofananionexchangemembrane