Cargando…

Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up

PURPOSE: The goal of this study was to investigate the long-term efficacy and safety of a mixture of polymethyl methacrylate (PMMA) and cross-linked dextran Lipen-10® used for penile augmentation under the physical impact generated during sexual intercourse. MATERIALS AND METHODS: From March 2010 to...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Ma Tae, Ko, Kyungtae, Lee, Won Ki, Kim, Sae Chul, Yang, Dae Yul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society for Sexual Medicine and Andrology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4709437/
https://www.ncbi.nlm.nih.gov/pubmed/26770941
http://dx.doi.org/10.5534/wjmh.2015.33.3.202
_version_ 1782409642819715072
author Kim, Ma Tae
Ko, Kyungtae
Lee, Won Ki
Kim, Sae Chul
Yang, Dae Yul
author_facet Kim, Ma Tae
Ko, Kyungtae
Lee, Won Ki
Kim, Sae Chul
Yang, Dae Yul
author_sort Kim, Ma Tae
collection PubMed
description PURPOSE: The goal of this study was to investigate the long-term efficacy and safety of a mixture of polymethyl methacrylate (PMMA) and cross-linked dextran Lipen-10® used for penile augmentation under the physical impact generated during sexual intercourse. MATERIALS AND METHODS: From March 2010 to October 2011, a total of 20 patients with a mean age of 44 years (interquartile range, 20~70 years) who requested penile augmentation participated in this study. Lipen-10® filler is a mixture of 75% cross-linked dextran, 15% PMMA, and 10% hypromellose solution. With the patient in the supine position, Lipen-10® was injected into the subcutaneous tissue between the dartos fascia and Buck's fascia of the penis using a fanning technique. Penile length and circumference were measured before the procedure and six, 12, and 18 months after the procedure. Values were compared using the Student's t-test and the paired t-test. RESULTS: A total of 15 patients completed this study. The increases in circumference and length observed six months after the procedure were found to have been maintained without change at 12 and 18 months of follow-up. At 12 and 18 months of follow-up, no abnormal findings were observed. Pelvic magnetic resonance imaging conducted at 18 months of follow-up showed no trace of the injected filler having migrated to other sites, and the volume was well maintained. CONCLUSIONS: Lipen-10®, a mixture of PMMA and cross-linked dextran, showed good durability and tolerability over 18 months of follow-up during which the participants were sexually active.
format Online
Article
Text
id pubmed-4709437
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Society for Sexual Medicine and Andrology
record_format MEDLINE/PubMed
spelling pubmed-47094372016-01-14 Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up Kim, Ma Tae Ko, Kyungtae Lee, Won Ki Kim, Sae Chul Yang, Dae Yul World J Mens Health Original Article PURPOSE: The goal of this study was to investigate the long-term efficacy and safety of a mixture of polymethyl methacrylate (PMMA) and cross-linked dextran Lipen-10® used for penile augmentation under the physical impact generated during sexual intercourse. MATERIALS AND METHODS: From March 2010 to October 2011, a total of 20 patients with a mean age of 44 years (interquartile range, 20~70 years) who requested penile augmentation participated in this study. Lipen-10® filler is a mixture of 75% cross-linked dextran, 15% PMMA, and 10% hypromellose solution. With the patient in the supine position, Lipen-10® was injected into the subcutaneous tissue between the dartos fascia and Buck's fascia of the penis using a fanning technique. Penile length and circumference were measured before the procedure and six, 12, and 18 months after the procedure. Values were compared using the Student's t-test and the paired t-test. RESULTS: A total of 15 patients completed this study. The increases in circumference and length observed six months after the procedure were found to have been maintained without change at 12 and 18 months of follow-up. At 12 and 18 months of follow-up, no abnormal findings were observed. Pelvic magnetic resonance imaging conducted at 18 months of follow-up showed no trace of the injected filler having migrated to other sites, and the volume was well maintained. CONCLUSIONS: Lipen-10®, a mixture of PMMA and cross-linked dextran, showed good durability and tolerability over 18 months of follow-up during which the participants were sexually active. Korean Society for Sexual Medicine and Andrology 2015-12 2015-12-23 /pmc/articles/PMC4709437/ /pubmed/26770941 http://dx.doi.org/10.5534/wjmh.2015.33.3.202 Text en Copyright © 2015 Korean Society for Sexual Medicine and Andrology http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Ma Tae
Ko, Kyungtae
Lee, Won Ki
Kim, Sae Chul
Yang, Dae Yul
Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up
title Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up
title_full Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up
title_fullStr Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up
title_full_unstemmed Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up
title_short Long-Term Safety and Longevity of a Mixture of Polymethyl Methacrylate and Cross-Linked Dextran (Lipen-10®) after Penile Augmentation: Extension Study from Six to 18 Months of Follow-Up
title_sort long-term safety and longevity of a mixture of polymethyl methacrylate and cross-linked dextran (lipen-10®) after penile augmentation: extension study from six to 18 months of follow-up
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4709437/
https://www.ncbi.nlm.nih.gov/pubmed/26770941
http://dx.doi.org/10.5534/wjmh.2015.33.3.202
work_keys_str_mv AT kimmatae longtermsafetyandlongevityofamixtureofpolymethylmethacrylateandcrosslinkeddextranlipen10afterpenileaugmentationextensionstudyfromsixto18monthsoffollowup
AT kokyungtae longtermsafetyandlongevityofamixtureofpolymethylmethacrylateandcrosslinkeddextranlipen10afterpenileaugmentationextensionstudyfromsixto18monthsoffollowup
AT leewonki longtermsafetyandlongevityofamixtureofpolymethylmethacrylateandcrosslinkeddextranlipen10afterpenileaugmentationextensionstudyfromsixto18monthsoffollowup
AT kimsaechul longtermsafetyandlongevityofamixtureofpolymethylmethacrylateandcrosslinkeddextranlipen10afterpenileaugmentationextensionstudyfromsixto18monthsoffollowup
AT yangdaeyul longtermsafetyandlongevityofamixtureofpolymethylmethacrylateandcrosslinkeddextranlipen10afterpenileaugmentationextensionstudyfromsixto18monthsoffollowup