Cargando…

Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation

INTRODUCTION: Mesenchymal stromal cells (MSCs) are well known for their application potential in tissue engineering. We previously reported that MSCs are able to differentiate into hepatocytes in vitro. However, conventional methods for estimating the maturation of hepatic differentiation require re...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Hao-Hsiang, Ho, Jennifer H., Lee, Oscar K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4709909/
https://www.ncbi.nlm.nih.gov/pubmed/26753763
http://dx.doi.org/10.1186/s13287-015-0259-y
_version_ 1782409737389735936
author Wu, Hao-Hsiang
Ho, Jennifer H.
Lee, Oscar K.
author_facet Wu, Hao-Hsiang
Ho, Jennifer H.
Lee, Oscar K.
author_sort Wu, Hao-Hsiang
collection PubMed
description INTRODUCTION: Mesenchymal stromal cells (MSCs) are well known for their application potential in tissue engineering. We previously reported that MSCs are able to differentiate into hepatocytes in vitro. However, conventional methods for estimating the maturation of hepatic differentiation require relatively large amounts of cell samples. Raman spectroscopy (RS), a photonic tool for acquisition of cell spectra by inelastic scattering, has been recently used as a label-free single-cell detector for biological applications including phenotypic changes and differentiation of cells and diagnosis. In this study, RS is used to real-time monitor the maturation of hepatic differentiation in live MSCs. METHODS: The MSCs were cultured on the type I collagen pre-coating substrate and differentiated into hepatocytes in vitro using a two-step protocol. The Raman spectra at different time points are acquired in the range 400–3000 cm(–1)and analyzed by quantification methods and principle component analysis during hepatic differentiation from the MSCs. RESULTS: The intensity of the broad band in the range 2800–3000 cm(–1) reflects the amount of glycogen within lipochrome in differentiated hepatocytes. A high correlation coefficient between the glycogen amount and hepatic maturation was exhibited. Moreover, principle component analysis of the Raman spectra from 400 to 3000 cm(–1) indicated that MSC-derived hepatocytes were close to the primary hepatocytes and were distinct from the undifferentiated MSCs. CONCLUSIONS: In summary, RS can serve as a rapid, non-invasive, real-time and label-free biosensor and reflects changes in live cell components during hepatic differentiation. The use of RS may thus facilitate the detection of hepatic differentiation and maturation in stem cells. Such an approach may substantially improve the feasibility as well as shorten the time required compared to the conventional molecular biology methods.
format Online
Article
Text
id pubmed-4709909
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47099092016-01-13 Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation Wu, Hao-Hsiang Ho, Jennifer H. Lee, Oscar K. Stem Cell Res Ther Research INTRODUCTION: Mesenchymal stromal cells (MSCs) are well known for their application potential in tissue engineering. We previously reported that MSCs are able to differentiate into hepatocytes in vitro. However, conventional methods for estimating the maturation of hepatic differentiation require relatively large amounts of cell samples. Raman spectroscopy (RS), a photonic tool for acquisition of cell spectra by inelastic scattering, has been recently used as a label-free single-cell detector for biological applications including phenotypic changes and differentiation of cells and diagnosis. In this study, RS is used to real-time monitor the maturation of hepatic differentiation in live MSCs. METHODS: The MSCs were cultured on the type I collagen pre-coating substrate and differentiated into hepatocytes in vitro using a two-step protocol. The Raman spectra at different time points are acquired in the range 400–3000 cm(–1)and analyzed by quantification methods and principle component analysis during hepatic differentiation from the MSCs. RESULTS: The intensity of the broad band in the range 2800–3000 cm(–1) reflects the amount of glycogen within lipochrome in differentiated hepatocytes. A high correlation coefficient between the glycogen amount and hepatic maturation was exhibited. Moreover, principle component analysis of the Raman spectra from 400 to 3000 cm(–1) indicated that MSC-derived hepatocytes were close to the primary hepatocytes and were distinct from the undifferentiated MSCs. CONCLUSIONS: In summary, RS can serve as a rapid, non-invasive, real-time and label-free biosensor and reflects changes in live cell components during hepatic differentiation. The use of RS may thus facilitate the detection of hepatic differentiation and maturation in stem cells. Such an approach may substantially improve the feasibility as well as shorten the time required compared to the conventional molecular biology methods. BioMed Central 2016-01-11 /pmc/articles/PMC4709909/ /pubmed/26753763 http://dx.doi.org/10.1186/s13287-015-0259-y Text en © Wu et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Wu, Hao-Hsiang
Ho, Jennifer H.
Lee, Oscar K.
Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
title Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
title_full Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
title_fullStr Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
title_full_unstemmed Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
title_short Detection of hepatic maturation by Raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
title_sort detection of hepatic maturation by raman spectroscopy in mesenchymal stromal cells undergoing hepatic differentiation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4709909/
https://www.ncbi.nlm.nih.gov/pubmed/26753763
http://dx.doi.org/10.1186/s13287-015-0259-y
work_keys_str_mv AT wuhaohsiang detectionofhepaticmaturationbyramanspectroscopyinmesenchymalstromalcellsundergoinghepaticdifferentiation
AT hojenniferh detectionofhepaticmaturationbyramanspectroscopyinmesenchymalstromalcellsundergoinghepaticdifferentiation
AT leeoscark detectionofhepaticmaturationbyramanspectroscopyinmesenchymalstromalcellsundergoinghepaticdifferentiation