Cargando…
Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults
BACKGROUD: To determine whether the professional Omron HBP-1300 blood pressure (BP) monitor meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards in Chinese children and adults. METHOD: According to the AAMI protocol, simultaneous auscultatory measuremen...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4711064/ https://www.ncbi.nlm.nih.gov/pubmed/26758197 http://dx.doi.org/10.1186/s12872-015-0177-z |
_version_ | 1782409911656775680 |
---|---|
author | Meng, Linghui Zhao, Di Pan, Yan Ding, Wenqing Wei, Qing Li, Hua Gao, Pingjin Mi, Jie |
author_facet | Meng, Linghui Zhao, Di Pan, Yan Ding, Wenqing Wei, Qing Li, Hua Gao, Pingjin Mi, Jie |
author_sort | Meng, Linghui |
collection | PubMed |
description | BACKGROUD: To determine whether the professional Omron HBP-1300 blood pressure (BP) monitor meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards in Chinese children and adults. METHOD: According to the AAMI protocol, simultaneous auscultatory measurements by two observers using a mercury manometer were obtained in participants using the Omron HBP-1300. Triple measurements were obtained after a minimum 5-min rest with a 1-min interval between adjacent measurements. RESULTS: A total of 85 participants submitted to 255 doctor-measured BP and 255 successful professional monitor readings. The initial auscultation systolic BP was <100 mmHg in 25 participants (29.4 %), 100–160 mmHg in 53 participants (62.4 %), and >160 mmHg in seven participants (8.2 %). All of the simultaneous measurements agreed to within ±10 mmHg, while 95 % agreed to within ±4 mmHg for both systolic and diastolic BP, and the consistency between two observers was satisfactory. The difference between the devices was -1.3 ± 3.6 mmHg for systolic BP and 0.7 ± 3.8 mmHg for diastolic BP and by AAMI method 1, which met this guideline. The average difference between two devices by AAMI method 2 was 1.4 ± 3.2 mmHg for systolic BP and 1.0 ± 3.9 mmHg for diastolic BP, which met this guideline. CONCLUSION: The professional BP monitor Omron HBP-1300 is desirable for measuring the BP for Chinese children and adults. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12872-015-0177-z) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4711064 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-47110642016-01-14 Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults Meng, Linghui Zhao, Di Pan, Yan Ding, Wenqing Wei, Qing Li, Hua Gao, Pingjin Mi, Jie BMC Cardiovasc Disord Research Article BACKGROUD: To determine whether the professional Omron HBP-1300 blood pressure (BP) monitor meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards in Chinese children and adults. METHOD: According to the AAMI protocol, simultaneous auscultatory measurements by two observers using a mercury manometer were obtained in participants using the Omron HBP-1300. Triple measurements were obtained after a minimum 5-min rest with a 1-min interval between adjacent measurements. RESULTS: A total of 85 participants submitted to 255 doctor-measured BP and 255 successful professional monitor readings. The initial auscultation systolic BP was <100 mmHg in 25 participants (29.4 %), 100–160 mmHg in 53 participants (62.4 %), and >160 mmHg in seven participants (8.2 %). All of the simultaneous measurements agreed to within ±10 mmHg, while 95 % agreed to within ±4 mmHg for both systolic and diastolic BP, and the consistency between two observers was satisfactory. The difference between the devices was -1.3 ± 3.6 mmHg for systolic BP and 0.7 ± 3.8 mmHg for diastolic BP and by AAMI method 1, which met this guideline. The average difference between two devices by AAMI method 2 was 1.4 ± 3.2 mmHg for systolic BP and 1.0 ± 3.9 mmHg for diastolic BP, which met this guideline. CONCLUSION: The professional BP monitor Omron HBP-1300 is desirable for measuring the BP for Chinese children and adults. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12872-015-0177-z) contains supplementary material, which is available to authorized users. BioMed Central 2016-01-13 /pmc/articles/PMC4711064/ /pubmed/26758197 http://dx.doi.org/10.1186/s12872-015-0177-z Text en © Meng et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Meng, Linghui Zhao, Di Pan, Yan Ding, Wenqing Wei, Qing Li, Hua Gao, Pingjin Mi, Jie Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults |
title | Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults |
title_full | Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults |
title_fullStr | Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults |
title_full_unstemmed | Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults |
title_short | Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults |
title_sort | validation of omron hbp-1300 professional blood pressure monitor based on auscultation in children and adults |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4711064/ https://www.ncbi.nlm.nih.gov/pubmed/26758197 http://dx.doi.org/10.1186/s12872-015-0177-z |
work_keys_str_mv | AT menglinghui validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT zhaodi validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT panyan validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT dingwenqing validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT weiqing validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT lihua validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT gaopingjin validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults AT mijie validationofomronhbp1300professionalbloodpressuremonitorbasedonauscultationinchildrenandadults |