A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†)
OBJECTIVE: Current endoscopic transection devices are not optimized to meet the unique challenges posed by the task of vessel transection in difficult-to-access locations within the pleural cavity. The ECHELON FLEX™ powered vascular stapler (PVS) has been designed with four rows of staples instead o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4711582/ https://www.ncbi.nlm.nih.gov/pubmed/26464450 http://dx.doi.org/10.1093/ejcts/ezv352 |
_version_ | 1782409952393953280 |
---|---|
author | Ng, Calvin S.H. Pickens, Allan Siegel, Julianne M. Clymer, Jeffrey W. Cummings, John F. |
author_facet | Ng, Calvin S.H. Pickens, Allan Siegel, Julianne M. Clymer, Jeffrey W. Cummings, John F. |
author_sort | Ng, Calvin S.H. |
collection | PubMed |
description | OBJECTIVE: Current endoscopic transection devices are not optimized to meet the unique challenges posed by the task of vessel transection in difficult-to-access locations within the pleural cavity. The ECHELON FLEX™ powered vascular stapler (PVS) has been designed with four rows of staples instead of six, to decrease its size and enable more precise placement on fragile pulmonary vessels, using a narrower anvil than other commercially available transecting devices. This study was performed to determine whether the reduced number of staple rows affects haemostasis, and to assess surgeons' initial impression of the smaller stapler during in vivo usage. METHODS: The new four-row stapler was compared with commercially available six-row articulating staplers via expert graders using a validated scale of haemostasis in vivo after application on porcine gastroepiploic pedicles and other thin- and thick-walled vessels. The new stapler was then compared with current products by practising thoracic surgeons (n = 27) during in vivo usage of simulated pulmonary procedures in a porcine model. The surgeons were also surveyed on the key attributes of the four-row stapler in relation to the six-row predicates. RESULTS: Haemostasis evaluated on an ordered scale was clinically equivalent between the test and predicate staplers, and was deemed acceptable for all thin- and thick-vascular tissue applications. Surgeons found no difference in haemostasis between the four- and six-row staplers (P = 0.486), and judged the four-row stapler superior in terms of access, reduced need for dissection, reduced stress of surgeon and precise control (P < 0.001 for all). CONCLUSIONS: The new ECHELON FLEX™ PVS provides haemostasis equivalent to six-row staplers. With a smaller anvil, narrower shaft and wider angle of articulation, the PVS demonstrated improved access capability for pulmonary vessel procedures. |
format | Online Article Text |
id | pubmed-4711582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-47115822016-01-14 A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) Ng, Calvin S.H. Pickens, Allan Siegel, Julianne M. Clymer, Jeffrey W. Cummings, John F. Eur J Cardiothorac Surg Original Articles OBJECTIVE: Current endoscopic transection devices are not optimized to meet the unique challenges posed by the task of vessel transection in difficult-to-access locations within the pleural cavity. The ECHELON FLEX™ powered vascular stapler (PVS) has been designed with four rows of staples instead of six, to decrease its size and enable more precise placement on fragile pulmonary vessels, using a narrower anvil than other commercially available transecting devices. This study was performed to determine whether the reduced number of staple rows affects haemostasis, and to assess surgeons' initial impression of the smaller stapler during in vivo usage. METHODS: The new four-row stapler was compared with commercially available six-row articulating staplers via expert graders using a validated scale of haemostasis in vivo after application on porcine gastroepiploic pedicles and other thin- and thick-walled vessels. The new stapler was then compared with current products by practising thoracic surgeons (n = 27) during in vivo usage of simulated pulmonary procedures in a porcine model. The surgeons were also surveyed on the key attributes of the four-row stapler in relation to the six-row predicates. RESULTS: Haemostasis evaluated on an ordered scale was clinically equivalent between the test and predicate staplers, and was deemed acceptable for all thin- and thick-vascular tissue applications. Surgeons found no difference in haemostasis between the four- and six-row staplers (P = 0.486), and judged the four-row stapler superior in terms of access, reduced need for dissection, reduced stress of surgeon and precise control (P < 0.001 for all). CONCLUSIONS: The new ECHELON FLEX™ PVS provides haemostasis equivalent to six-row staplers. With a smaller anvil, narrower shaft and wider angle of articulation, the PVS demonstrated improved access capability for pulmonary vessel procedures. Oxford University Press 2016-01 2015-10-31 /pmc/articles/PMC4711582/ /pubmed/26464450 http://dx.doi.org/10.1093/ejcts/ezv352 Text en © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Articles Ng, Calvin S.H. Pickens, Allan Siegel, Julianne M. Clymer, Jeffrey W. Cummings, John F. A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
title | A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
title_full | A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
title_fullStr | A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
title_full_unstemmed | A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
title_short | A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
title_sort | novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices(†) |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4711582/ https://www.ncbi.nlm.nih.gov/pubmed/26464450 http://dx.doi.org/10.1093/ejcts/ezv352 |
work_keys_str_mv | AT ngcalvinsh anovelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT pickensallan anovelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT siegeljuliannem anovelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT clymerjeffreyw anovelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT cummingsjohnf anovelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT ngcalvinsh novelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT pickensallan novelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT siegeljuliannem novelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT clymerjeffreyw novelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices AT cummingsjohnf novelnarrowprofilearticulatingpoweredvascularstaplerprovidessuperioraccessandhaemostasisequivalenttoconventionaldevices |