Cargando…

Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study

BACKGROUND: The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. This study aims to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Platon, Alexandra, Becker, Minerva, Becker, Christoph D., Lock, Eric, Wolff, Hans, Perneger, Thomas, Poletti, Pierre-Alexandre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4712503/
https://www.ncbi.nlm.nih.gov/pubmed/26762344
http://dx.doi.org/10.1186/s12880-016-0106-3
_version_ 1782410076241264640
author Platon, Alexandra
Becker, Minerva
Becker, Christoph D.
Lock, Eric
Wolff, Hans
Perneger, Thomas
Poletti, Pierre-Alexandre
author_facet Platon, Alexandra
Becker, Minerva
Becker, Christoph D.
Lock, Eric
Wolff, Hans
Perneger, Thomas
Poletti, Pierre-Alexandre
author_sort Platon, Alexandra
collection PubMed
description BACKGROUND: The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. This study aims to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets. METHODS: The study was approved by the institutional review board of our institution (CER 13_027_R). From November 2010 to May 2013, all consecutive conveyors in whom a low-dose abdominal CT (LDCT) revealed the presence of illegal intra-corporeal drug packets underwent a dual energy CT series (gemstone spectral imaging) targeted on one container. The mean radiological density (HU) of these packets was measured on the LDCT series, and on the monochromatic dual energy series, at 40 and 140 keV. The difference between the HU at 40 and 140 keV was reported as ∆HU. The effective atomic number Z(eff) was also measured on the monochromatic series. A chemical analysis was performed after expulsion to select cocaine containing packets, and to determine their cocaine concentrations. A correlation analysis was performed between HU, ∆HU and Z(eff), with regard to the percentage of cocaine. RESULTS: Fifty-four cocaine conveyors were included. The mean cocaine content of the packets was 36.8 % (range 11.2–80, SD 15.4), the mean radiologic density 105 HU, the mean Z(eff) 8.7 and the mean ∆HU 163. The cocaine content was correlated with the ∆HU (0.57, p < 0.001), with the Z(eff) (r = 0.56, p < 0.001) but not with radiologic density (r = 0.25, p = 0.064). ∆HU >200 was 0.9 (9 of 10) sensitive and 0.82 (36 of 44) specific to predict a cocaine concentration higher than 50 %. CONCLUSION: Measuring ∆HU or Z(eff) on dual energy monochromatic CT series can be used to detect ingested packets with cocaine concentration >50 %.
format Online
Article
Text
id pubmed-4712503
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47125032016-01-15 Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study Platon, Alexandra Becker, Minerva Becker, Christoph D. Lock, Eric Wolff, Hans Perneger, Thomas Poletti, Pierre-Alexandre BMC Med Imaging Research Article BACKGROUND: The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. This study aims to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets. METHODS: The study was approved by the institutional review board of our institution (CER 13_027_R). From November 2010 to May 2013, all consecutive conveyors in whom a low-dose abdominal CT (LDCT) revealed the presence of illegal intra-corporeal drug packets underwent a dual energy CT series (gemstone spectral imaging) targeted on one container. The mean radiological density (HU) of these packets was measured on the LDCT series, and on the monochromatic dual energy series, at 40 and 140 keV. The difference between the HU at 40 and 140 keV was reported as ∆HU. The effective atomic number Z(eff) was also measured on the monochromatic series. A chemical analysis was performed after expulsion to select cocaine containing packets, and to determine their cocaine concentrations. A correlation analysis was performed between HU, ∆HU and Z(eff), with regard to the percentage of cocaine. RESULTS: Fifty-four cocaine conveyors were included. The mean cocaine content of the packets was 36.8 % (range 11.2–80, SD 15.4), the mean radiologic density 105 HU, the mean Z(eff) 8.7 and the mean ∆HU 163. The cocaine content was correlated with the ∆HU (0.57, p < 0.001), with the Z(eff) (r = 0.56, p < 0.001) but not with radiologic density (r = 0.25, p = 0.064). ∆HU >200 was 0.9 (9 of 10) sensitive and 0.82 (36 of 44) specific to predict a cocaine concentration higher than 50 %. CONCLUSION: Measuring ∆HU or Z(eff) on dual energy monochromatic CT series can be used to detect ingested packets with cocaine concentration >50 %. BioMed Central 2016-01-13 /pmc/articles/PMC4712503/ /pubmed/26762344 http://dx.doi.org/10.1186/s12880-016-0106-3 Text en © Platon et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Platon, Alexandra
Becker, Minerva
Becker, Christoph D.
Lock, Eric
Wolff, Hans
Perneger, Thomas
Poletti, Pierre-Alexandre
Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
title Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
title_full Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
title_fullStr Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
title_full_unstemmed Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
title_short Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
title_sort illegal intra-corporeal packets: can dual energy ct be used for the evaluation of cocaine concentration? a cross sectional study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4712503/
https://www.ncbi.nlm.nih.gov/pubmed/26762344
http://dx.doi.org/10.1186/s12880-016-0106-3
work_keys_str_mv AT platonalexandra illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy
AT beckerminerva illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy
AT beckerchristophd illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy
AT lockeric illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy
AT wolffhans illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy
AT pernegerthomas illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy
AT polettipierrealexandre illegalintracorporealpacketscandualenergyctbeusedfortheevaluationofcocaineconcentrationacrosssectionalstudy