Cargando…

Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures

Background and study aims: The treatment success of benign biliary strictures with fully covered metal stents (CSEMS) is altered by high stent dislocation rates. We aimed to evaluate a new stent design to prevent dislocation. Patients and methods: Patients with benign biliary strictures were treated...

Descripción completa

Detalles Bibliográficos
Autores principales: Weigt, Jochen, Kandulski, Arne, Malfertheiner, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4713183/
https://www.ncbi.nlm.nih.gov/pubmed/26793789
http://dx.doi.org/10.1055/s-0034-1393583
_version_ 1782410160579280896
author Weigt, Jochen
Kandulski, Arne
Malfertheiner, Peter
author_facet Weigt, Jochen
Kandulski, Arne
Malfertheiner, Peter
author_sort Weigt, Jochen
collection PubMed
description Background and study aims: The treatment success of benign biliary strictures with fully covered metal stents (CSEMS) is altered by high stent dislocation rates. We aimed to evaluate a new stent design to prevent dislocation. Patients and methods: Patients with benign biliary strictures were treated with a newly designed double-coned stent (dcSEMS). Mechanical analysis of the new stent was performed and it was compared with a cylindrical stent. Results: A total of 13 dcCSEMS were implanted in 11 patients (2 female, 9 male, median age 47, range 33 – 71). All patients had distal biliary strictures due to chronic pancreatitis. No stent migration occurred. In all but one patient the stents were removed. One patient refused stent extraction and was lost to follow up. Stent occlusion occurred twice leading to cholangitis in both cases. The duration of stent treatment was 170 days (range 61 – 254). After extraction only one patient had early recurrent stricture and received the same stent again. Three stents showed minimal tissue granulation at the papilla. One stent presented ingrowth at the proximal end and was removed after implantation of a second fully covered stent. Mechanical examination revealed significantly lower radial expansion force of the new stent as compared to the cylindrical stent. Conclusions: The new stent design has a low rate of migration. Biomechanical properties may explain this effect.
format Online
Article
Text
id pubmed-4713183
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher © Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-47131832016-01-20 Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures Weigt, Jochen Kandulski, Arne Malfertheiner, Peter Endosc Int Open Article Background and study aims: The treatment success of benign biliary strictures with fully covered metal stents (CSEMS) is altered by high stent dislocation rates. We aimed to evaluate a new stent design to prevent dislocation. Patients and methods: Patients with benign biliary strictures were treated with a newly designed double-coned stent (dcSEMS). Mechanical analysis of the new stent was performed and it was compared with a cylindrical stent. Results: A total of 13 dcCSEMS were implanted in 11 patients (2 female, 9 male, median age 47, range 33 – 71). All patients had distal biliary strictures due to chronic pancreatitis. No stent migration occurred. In all but one patient the stents were removed. One patient refused stent extraction and was lost to follow up. Stent occlusion occurred twice leading to cholangitis in both cases. The duration of stent treatment was 170 days (range 61 – 254). After extraction only one patient had early recurrent stricture and received the same stent again. Three stents showed minimal tissue granulation at the papilla. One stent presented ingrowth at the proximal end and was removed after implantation of a second fully covered stent. Mechanical examination revealed significantly lower radial expansion force of the new stent as compared to the cylindrical stent. Conclusions: The new stent design has a low rate of migration. Biomechanical properties may explain this effect. © Georg Thieme Verlag KG 2016-01 2015-11-27 /pmc/articles/PMC4713183/ /pubmed/26793789 http://dx.doi.org/10.1055/s-0034-1393583 Text en © Thieme Medical Publishers
spellingShingle Article
Weigt, Jochen
Kandulski, Arne
Malfertheiner, Peter
Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
title Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
title_full Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
title_fullStr Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
title_full_unstemmed Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
title_short Anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
title_sort anatomy-shaped design of a fully-covered, biliary, self-expandable metal stent for treatment of benign distal biliary strictures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4713183/
https://www.ncbi.nlm.nih.gov/pubmed/26793789
http://dx.doi.org/10.1055/s-0034-1393583
work_keys_str_mv AT weigtjochen anatomyshapeddesignofafullycoveredbiliaryselfexpandablemetalstentfortreatmentofbenigndistalbiliarystrictures
AT kandulskiarne anatomyshapeddesignofafullycoveredbiliaryselfexpandablemetalstentfortreatmentofbenigndistalbiliarystrictures
AT malfertheinerpeter anatomyshapeddesignofafullycoveredbiliaryselfexpandablemetalstentfortreatmentofbenigndistalbiliarystrictures