[Purpose] The purpose of this study was to investigate the effects of using a device for the self-measurement of cervical range of motion on neck pain experienced by a computer user. [Subject] A 39-year-old male subject with neck pain caused by working on a computer was selected for the study. [Meth...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4713827/ https://www.ncbi.nlm.nih.gov/pubmed/26834388 http://dx.doi.org/10.1589/jpts.27.3947 |
_version_ | 1782410207065800704 |
---|---|
author | Yoo, Won-gyu |
author_facet | Yoo, Won-gyu |
author_sort | Yoo, Won-gyu |
collection | PubMed |
description | [Purpose] The purpose of this study was to investigate the effects of using a device for the self-measurement of cervical range of motion on neck pain experienced by a computer user. [Subject] A 39-year-old male subject with neck pain caused by working on a computer was selected for the study. [Methods] The instrument was developed for the study, and that the instrument is used to self-measure cervical range of movement. The subject was trained in self-measurement procedures and a self-exercise program for two months, and pain was controlled through self-assessment and a program. The pressure pain threshold for the upper trapezius muscle, and cervical ranges of motion were measured prior to and after the 2-month period of pain control. [Results] At the conclusion of self-measurement and the self-exercise program, the pressure pain threshold was higher than the initial pressure pain threshold, and all cervical ranges of motion increased compared to the initial cervical ranges of motion. [Conclusion] This result shows that the self-management device for cervical ROM is an effective tool for pain management for computer users with cervical pain. |
format | Online Article Text |
id | pubmed-4713827 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47138272016-01-29 Effects of using a device for self-measurement of cervical ROM on neck pain of computer user Yoo, Won-gyu J Phys Ther Sci Case Study [Purpose] The purpose of this study was to investigate the effects of using a device for the self-measurement of cervical range of motion on neck pain experienced by a computer user. [Subject] A 39-year-old male subject with neck pain caused by working on a computer was selected for the study. [Methods] The instrument was developed for the study, and that the instrument is used to self-measure cervical range of movement. The subject was trained in self-measurement procedures and a self-exercise program for two months, and pain was controlled through self-assessment and a program. The pressure pain threshold for the upper trapezius muscle, and cervical ranges of motion were measured prior to and after the 2-month period of pain control. [Results] At the conclusion of self-measurement and the self-exercise program, the pressure pain threshold was higher than the initial pressure pain threshold, and all cervical ranges of motion increased compared to the initial cervical ranges of motion. [Conclusion] This result shows that the self-management device for cervical ROM is an effective tool for pain management for computer users with cervical pain. The Society of Physical Therapy Science 2015-12-28 2015-12 /pmc/articles/PMC4713827/ /pubmed/26834388 http://dx.doi.org/10.1589/jpts.27.3947 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. |
spellingShingle | Case Study Yoo, Won-gyu Effects of using a device for self-measurement of cervical ROM on neck pain of computer user |
title | Effects of using a device for self-measurement of cervical ROM on neck pain
of computer user |
title_full | Effects of using a device for self-measurement of cervical ROM on neck pain
of computer user |
title_fullStr | Effects of using a device for self-measurement of cervical ROM on neck pain
of computer user |
title_full_unstemmed | Effects of using a device for self-measurement of cervical ROM on neck pain
of computer user |
title_short | Effects of using a device for self-measurement of cervical ROM on neck pain
of computer user |
title_sort | effects of using a device for self-measurement of cervical rom on neck pain
of computer user |
topic | Case Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4713827/ https://www.ncbi.nlm.nih.gov/pubmed/26834388 http://dx.doi.org/10.1589/jpts.27.3947 |
work_keys_str_mv | AT yoowongyu effectsofusingadeviceforselfmeasurementofcervicalromonneckpainofcomputeruser |