Cargando…
Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus
BACKGROUND: The aim of this study was to design a new minimally invasive percutaneous lag screw guide apparatus and to verify its adjuvant treatment of acetabular anterior column fracture on pelvis specimens. METHODS: This guide apparatus was self-developed based on the principles of “two points for...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4714437/ https://www.ncbi.nlm.nih.gov/pubmed/26769591 http://dx.doi.org/10.1186/s12891-015-0846-1 |
_version_ | 1782410320041476096 |
---|---|
author | Zhang, Li-hai Zhang, Li-cheng Si, Qing-hua Gao, Yuan Su, Xiu-yun Zhao, Zhe Tang, Pei-fu |
author_facet | Zhang, Li-hai Zhang, Li-cheng Si, Qing-hua Gao, Yuan Su, Xiu-yun Zhao, Zhe Tang, Pei-fu |
author_sort | Zhang, Li-hai |
collection | PubMed |
description | BACKGROUND: The aim of this study was to design a new minimally invasive percutaneous lag screw guide apparatus and to verify its adjuvant treatment of acetabular anterior column fracture on pelvis specimens. METHODS: This guide apparatus was self-developed based on the principles of “two points form a line” and “Rectangle”. Using C-arm fluoroscopy, this guide apparatus was used to conduct minimally invasive percutaneous lag screw internal fixation of acetabular anterior column fractures. Ten hollow lag screws were placed into 5 pelvis specimens. RESULT: Result showed no sign of any screws puncturing the cortex or entering into the hip joint on radiological assessment. The cross-section reconstructed vertical distance to the screw, on the cross-section acetabular notch and the cross-section of the screw where the distance of between the screw and the iliopectineal line’s arc roof was at its shortest, indicate that at all points (T, R-r) under the line with an inclination of 1 (namely T = R-r) the screw is within the cortex and does not puncture the acetabula anterior column or enter into the hip joint. CONCLUSIONS: We may conclude that this self-developed guide apparatus solves the screw precision problem during the treatment of acetabular anterior column fractures through a minimally invasive percutaneous lag screw. |
format | Online Article Text |
id | pubmed-4714437 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-47144372016-01-16 Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus Zhang, Li-hai Zhang, Li-cheng Si, Qing-hua Gao, Yuan Su, Xiu-yun Zhao, Zhe Tang, Pei-fu BMC Musculoskelet Disord Research Article BACKGROUND: The aim of this study was to design a new minimally invasive percutaneous lag screw guide apparatus and to verify its adjuvant treatment of acetabular anterior column fracture on pelvis specimens. METHODS: This guide apparatus was self-developed based on the principles of “two points form a line” and “Rectangle”. Using C-arm fluoroscopy, this guide apparatus was used to conduct minimally invasive percutaneous lag screw internal fixation of acetabular anterior column fractures. Ten hollow lag screws were placed into 5 pelvis specimens. RESULT: Result showed no sign of any screws puncturing the cortex or entering into the hip joint on radiological assessment. The cross-section reconstructed vertical distance to the screw, on the cross-section acetabular notch and the cross-section of the screw where the distance of between the screw and the iliopectineal line’s arc roof was at its shortest, indicate that at all points (T, R-r) under the line with an inclination of 1 (namely T = R-r) the screw is within the cortex and does not puncture the acetabula anterior column or enter into the hip joint. CONCLUSIONS: We may conclude that this self-developed guide apparatus solves the screw precision problem during the treatment of acetabular anterior column fractures through a minimally invasive percutaneous lag screw. BioMed Central 2016-01-15 /pmc/articles/PMC4714437/ /pubmed/26769591 http://dx.doi.org/10.1186/s12891-015-0846-1 Text en © Zhang et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Zhang, Li-hai Zhang, Li-cheng Si, Qing-hua Gao, Yuan Su, Xiu-yun Zhao, Zhe Tang, Pei-fu Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
title | Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
title_full | Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
title_fullStr | Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
title_full_unstemmed | Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
title_short | Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
title_sort | experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4714437/ https://www.ncbi.nlm.nih.gov/pubmed/26769591 http://dx.doi.org/10.1186/s12891-015-0846-1 |
work_keys_str_mv | AT zhanglihai experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus AT zhanglicheng experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus AT siqinghua experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus AT gaoyuan experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus AT suxiuyun experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus AT zhaozhe experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus AT tangpeifu experimentalstudyontreatmentofacetabularanteriorcolumnfracturesapplymentofaminimallyinvasivepercutaneouslagscrewguideapparatus |