Cargando…

System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure

Pathologic changes in intracranial pressure (ICP) are commonly observed in a variety of medical conditions, including traumatic brain injury, stroke, brain tumors, and glaucoma. However, current ICP measurement techniques are invasive, requiring a lumbar puncture or surgical insertion of a cannula i...

Descripción completa

Detalles Bibliográficos
Autores principales: Stockslager, Max A., Samuels, Brian C., Allingham, R. Rand, Klesmith, Zoe A., Schwaner, Stephen A., Forest, Craig R., Ethier, C. Ross
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4714900/
https://www.ncbi.nlm.nih.gov/pubmed/26771837
http://dx.doi.org/10.1371/journal.pone.0147020
_version_ 1782410386211864576
author Stockslager, Max A.
Samuels, Brian C.
Allingham, R. Rand
Klesmith, Zoe A.
Schwaner, Stephen A.
Forest, Craig R.
Ethier, C. Ross
author_facet Stockslager, Max A.
Samuels, Brian C.
Allingham, R. Rand
Klesmith, Zoe A.
Schwaner, Stephen A.
Forest, Craig R.
Ethier, C. Ross
author_sort Stockslager, Max A.
collection PubMed
description Pathologic changes in intracranial pressure (ICP) are commonly observed in a variety of medical conditions, including traumatic brain injury, stroke, brain tumors, and glaucoma. However, current ICP measurement techniques are invasive, requiring a lumbar puncture or surgical insertion of a cannula into the cerebrospinal fluid (CSF)-filled ventricles of the brain. A potential alternative approach to ICP measurement leverages the unique anatomy of the central retinal vein, which is exposed to both intraocular pressure (IOP) and ICP as it travels inside the eye and through the optic nerve; manipulating IOP while observing changes in the natural pulsations of the central retinal vein could potentially provide an accurate, indirect measure of ICP. As a step toward implementing this technique, we describe the design, fabrication, and characterization of a system that is capable of manipulating IOP in vivo with <0.1 mmHg resolution and settling times less than 2 seconds. In vitro tests were carried out to characterize system performance. Then, as a proof of concept, we used the system to manipulate IOP in tree shrews (Tupaia belangeri) while video of the retinal vessels was recorded and the caliber of a selected vein was quantified. Modulating IOP using our system elicited a rapid change in the appearance of the retinal vein of interest: IOP was lowered from 10 to 3 mmHg, and retinal vein caliber sharply increased as IOP decreased from 7 to 5 mmHg. Another important feature of this technology is its capability to measure ocular compliance and outflow facility in vivo, as demonstrated in tree shrews. Collectively, these proof-of-concept demonstrations support the utility of this system to manipulate IOP for a variety of useful applications in ocular biomechanics, and provide a framework for further study of the mechanisms of retinal venous pulsation.
format Online
Article
Text
id pubmed-4714900
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47149002016-01-30 System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure Stockslager, Max A. Samuels, Brian C. Allingham, R. Rand Klesmith, Zoe A. Schwaner, Stephen A. Forest, Craig R. Ethier, C. Ross PLoS One Research Article Pathologic changes in intracranial pressure (ICP) are commonly observed in a variety of medical conditions, including traumatic brain injury, stroke, brain tumors, and glaucoma. However, current ICP measurement techniques are invasive, requiring a lumbar puncture or surgical insertion of a cannula into the cerebrospinal fluid (CSF)-filled ventricles of the brain. A potential alternative approach to ICP measurement leverages the unique anatomy of the central retinal vein, which is exposed to both intraocular pressure (IOP) and ICP as it travels inside the eye and through the optic nerve; manipulating IOP while observing changes in the natural pulsations of the central retinal vein could potentially provide an accurate, indirect measure of ICP. As a step toward implementing this technique, we describe the design, fabrication, and characterization of a system that is capable of manipulating IOP in vivo with <0.1 mmHg resolution and settling times less than 2 seconds. In vitro tests were carried out to characterize system performance. Then, as a proof of concept, we used the system to manipulate IOP in tree shrews (Tupaia belangeri) while video of the retinal vessels was recorded and the caliber of a selected vein was quantified. Modulating IOP using our system elicited a rapid change in the appearance of the retinal vein of interest: IOP was lowered from 10 to 3 mmHg, and retinal vein caliber sharply increased as IOP decreased from 7 to 5 mmHg. Another important feature of this technology is its capability to measure ocular compliance and outflow facility in vivo, as demonstrated in tree shrews. Collectively, these proof-of-concept demonstrations support the utility of this system to manipulate IOP for a variety of useful applications in ocular biomechanics, and provide a framework for further study of the mechanisms of retinal venous pulsation. Public Library of Science 2016-01-15 /pmc/articles/PMC4714900/ /pubmed/26771837 http://dx.doi.org/10.1371/journal.pone.0147020 Text en © 2016 Stockslager et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Stockslager, Max A.
Samuels, Brian C.
Allingham, R. Rand
Klesmith, Zoe A.
Schwaner, Stephen A.
Forest, Craig R.
Ethier, C. Ross
System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure
title System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure
title_full System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure
title_fullStr System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure
title_full_unstemmed System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure
title_short System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure
title_sort system for rapid, precise modulation of intraocular pressure, toward minimally-invasive in vivo measurement of intracranial pressure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4714900/
https://www.ncbi.nlm.nih.gov/pubmed/26771837
http://dx.doi.org/10.1371/journal.pone.0147020
work_keys_str_mv AT stockslagermaxa systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure
AT samuelsbrianc systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure
AT allinghamrrand systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure
AT klesmithzoea systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure
AT schwanerstephena systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure
AT forestcraigr systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure
AT ethiercross systemforrapidprecisemodulationofintraocularpressuretowardminimallyinvasiveinvivomeasurementofintracranialpressure