Cargando…

Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy

PURPOSE: The purpose of this study is to evaluate our first experience with 3D image-guided breast brachytherapy and to compare dose distribution parameters between Paris dosimetry system (PDS) and image-based plans. MATERIAL AND METHODS: First 49 breast cancer patients treated with 3D high-dose-rat...

Descripción completa

Detalles Bibliográficos
Autores principales: Wiercińska, Judyta, Wronczewska, Anna, Kabacińska, Renata, Makarewicz, Roman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4716128/
https://www.ncbi.nlm.nih.gov/pubmed/26816505
http://dx.doi.org/10.5114/jcb.2015.56492
_version_ 1782410505473753088
author Wiercińska, Judyta
Wronczewska, Anna
Kabacińska, Renata
Makarewicz, Roman
author_facet Wiercińska, Judyta
Wronczewska, Anna
Kabacińska, Renata
Makarewicz, Roman
author_sort Wiercińska, Judyta
collection PubMed
description PURPOSE: The purpose of this study is to evaluate our first experience with 3D image-guided breast brachytherapy and to compare dose distribution parameters between Paris dosimetry system (PDS) and image-based plans. MATERIAL AND METHODS: First 49 breast cancer patients treated with 3D high-dose-rate interstitial brachytherapy as a boost were selected for the study. Every patient underwent computed tomography, and the planning target volume (PTV) and organs at risk (OAR) were outlined. Two treatment plans were created for every patient. First, based on a Paris dosimetry system (PDS), and the second one, imaged-based plan with graphical optimization (OPT). The reference isodose in PDS implants was 85%, whereas in OPT plans the isodose was chosen to obtain proper target coverage. Dose and volume parameters (D(90), D(100), V(90), V(100)), doses at OARs, total reference air kerma (TRAK), and quality assurance parameters: dose nonuniformity ratio (DNR), dose homogeneity index (DHI), and conformity index (COIN) were used for a comparison of both plans. RESULTS: The mean number of catheters was 7 but the mean for 20 first patients was 5 and almost 9 for the next 29 patients. The mean value of prescribed isodose for OPT plans was 73%. The mean D(90) was 88.2% and 105.8%, the D(100) was 59.8% and 75.7%, the V(PTV90) was 88.6% and 98.1%, the V(PTV100) was 79.9% and 98.9%, and the TRAK was 0.00375 Gym(–1) and 0.00439 Gym(–1) for the PDS and OPT plans, respectively. The mean DNR was 0.29 and 0.42, the DHI was 0.71 and 0.58, and the COIN was 0.68 and 0.76, respectively. CONCLUSIONS: The target coverage in image-guided plans (OPT) was significantly higher than in PDS plans but the dose homogeneity was worse. Also, the value of TRAK increased because of change of prescribing isodose. The learning curve slightly affected our results.
format Online
Article
Text
id pubmed-4716128
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-47161282016-01-26 Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy Wiercińska, Judyta Wronczewska, Anna Kabacińska, Renata Makarewicz, Roman J Contemp Brachytherapy Original Paper PURPOSE: The purpose of this study is to evaluate our first experience with 3D image-guided breast brachytherapy and to compare dose distribution parameters between Paris dosimetry system (PDS) and image-based plans. MATERIAL AND METHODS: First 49 breast cancer patients treated with 3D high-dose-rate interstitial brachytherapy as a boost were selected for the study. Every patient underwent computed tomography, and the planning target volume (PTV) and organs at risk (OAR) were outlined. Two treatment plans were created for every patient. First, based on a Paris dosimetry system (PDS), and the second one, imaged-based plan with graphical optimization (OPT). The reference isodose in PDS implants was 85%, whereas in OPT plans the isodose was chosen to obtain proper target coverage. Dose and volume parameters (D(90), D(100), V(90), V(100)), doses at OARs, total reference air kerma (TRAK), and quality assurance parameters: dose nonuniformity ratio (DNR), dose homogeneity index (DHI), and conformity index (COIN) were used for a comparison of both plans. RESULTS: The mean number of catheters was 7 but the mean for 20 first patients was 5 and almost 9 for the next 29 patients. The mean value of prescribed isodose for OPT plans was 73%. The mean D(90) was 88.2% and 105.8%, the D(100) was 59.8% and 75.7%, the V(PTV90) was 88.6% and 98.1%, the V(PTV100) was 79.9% and 98.9%, and the TRAK was 0.00375 Gym(–1) and 0.00439 Gym(–1) for the PDS and OPT plans, respectively. The mean DNR was 0.29 and 0.42, the DHI was 0.71 and 0.58, and the COIN was 0.68 and 0.76, respectively. CONCLUSIONS: The target coverage in image-guided plans (OPT) was significantly higher than in PDS plans but the dose homogeneity was worse. Also, the value of TRAK increased because of change of prescribing isodose. The learning curve slightly affected our results. Termedia Publishing House 2015-12-16 2015-12 /pmc/articles/PMC4716128/ /pubmed/26816505 http://dx.doi.org/10.5114/jcb.2015.56492 Text en Copyright © 2015 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Wiercińska, Judyta
Wronczewska, Anna
Kabacińska, Renata
Makarewicz, Roman
Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy
title Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy
title_full Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy
title_fullStr Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy
title_full_unstemmed Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy
title_short Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy
title_sort transition from paris dosimetry system to 3d image-guided planning in interstitial breast brachytherapy
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4716128/
https://www.ncbi.nlm.nih.gov/pubmed/26816505
http://dx.doi.org/10.5114/jcb.2015.56492
work_keys_str_mv AT wiercinskajudyta transitionfromparisdosimetrysystemto3dimageguidedplanningininterstitialbreastbrachytherapy
AT wronczewskaanna transitionfromparisdosimetrysystemto3dimageguidedplanningininterstitialbreastbrachytherapy
AT kabacinskarenata transitionfromparisdosimetrysystemto3dimageguidedplanningininterstitialbreastbrachytherapy
AT makarewiczroman transitionfromparisdosimetrysystemto3dimageguidedplanningininterstitialbreastbrachytherapy