Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation

PURPOSE: Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this...

Descripción completa

Detalles Bibliográficos
Autores principales: Akhtari, Mani, Pino, Ramiro, Scarboro, Sarah B., Bass, Barbara L., Miltenburg, Darlene M., Butler, E. Brian, Teh, Bin S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4716129/
https://www.ncbi.nlm.nih.gov/pubmed/26816499
http://dx.doi.org/10.5114/jcb.2015.56515
_version_ 1782410505727508480
author Akhtari, Mani
Pino, Ramiro
Scarboro, Sarah B.
Bass, Barbara L.
Miltenburg, Darlene M.
Butler, E. Brian
Teh, Bin S.
author_facet Akhtari, Mani
Pino, Ramiro
Scarboro, Sarah B.
Bass, Barbara L.
Miltenburg, Darlene M.
Butler, E. Brian
Teh, Bin S.
author_sort Akhtari, Mani
collection PubMed
description PURPOSE: Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosmetic outcome for this population of patients at our institution. MATERIAL AND METHODS: We report the treatment and outcome of seven consecutive patients with existing breast implants and early stage breast cancer who were treated between 2009 and 2013 using APBI following lumpectomy. All patients were treated twice per day for five days to a total dose of 34 Gy using a high-dose-rate (192)Ir source. Cosmetic outcomes were evaluated using the Harvard breast cosmesis scale, and late toxicities were reported using the Radiation Therapy Oncology Group (RTOG) late radiation morbidity schema. RESULTS: After a mean follow-up of 32 months, all patients have remained cancer free. Six out of seven patients had an excellent or good cosmetic outcome. There were no grade 3 or 4 late toxicities. The average total breast implant volume was 279.3 cc, received an average mean dose of 12.1 Gy, and a maximum dose of 234.1 Gy. The average percentage of breast implant volume receiving 50%, 75%, 100%, 150%, and 200% of the prescribed dose was 15.6%, 7.03%, 4.6%, 1.58%, and 0.46%, respectively. Absolute volume of breast implants receiving more than 50% of prescribed dose correlated with worse cosmetic outcomes. CONCLUSIONS: Accelerated partial breast irradiation using a multi-lumen applicator in patients with existing breast implants can safely be performed with promising early clinical results. The presence of the implant did not compromise the ability to achieve dosimetric criteria; however, dose to the implant and the irradiated implant volume may be related with worse cosmetic outcomes.
format Online
Article
Text
id pubmed-4716129
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-47161292016-01-26 Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation Akhtari, Mani Pino, Ramiro Scarboro, Sarah B. Bass, Barbara L. Miltenburg, Darlene M. Butler, E. Brian Teh, Bin S. J Contemp Brachytherapy Original Paper PURPOSE: Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosmetic outcome for this population of patients at our institution. MATERIAL AND METHODS: We report the treatment and outcome of seven consecutive patients with existing breast implants and early stage breast cancer who were treated between 2009 and 2013 using APBI following lumpectomy. All patients were treated twice per day for five days to a total dose of 34 Gy using a high-dose-rate (192)Ir source. Cosmetic outcomes were evaluated using the Harvard breast cosmesis scale, and late toxicities were reported using the Radiation Therapy Oncology Group (RTOG) late radiation morbidity schema. RESULTS: After a mean follow-up of 32 months, all patients have remained cancer free. Six out of seven patients had an excellent or good cosmetic outcome. There were no grade 3 or 4 late toxicities. The average total breast implant volume was 279.3 cc, received an average mean dose of 12.1 Gy, and a maximum dose of 234.1 Gy. The average percentage of breast implant volume receiving 50%, 75%, 100%, 150%, and 200% of the prescribed dose was 15.6%, 7.03%, 4.6%, 1.58%, and 0.46%, respectively. Absolute volume of breast implants receiving more than 50% of prescribed dose correlated with worse cosmetic outcomes. CONCLUSIONS: Accelerated partial breast irradiation using a multi-lumen applicator in patients with existing breast implants can safely be performed with promising early clinical results. The presence of the implant did not compromise the ability to achieve dosimetric criteria; however, dose to the implant and the irradiated implant volume may be related with worse cosmetic outcomes. Termedia Publishing House 2015-12-17 2015-12 /pmc/articles/PMC4716129/ /pubmed/26816499 http://dx.doi.org/10.5114/jcb.2015.56515 Text en Copyright © 2015 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Akhtari, Mani
Pino, Ramiro
Scarboro, Sarah B.
Bass, Barbara L.
Miltenburg, Darlene M.
Butler, E. Brian
Teh, Bin S.
Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
title Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
title_full Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
title_fullStr Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
title_full_unstemmed Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
title_short Dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
title_sort dosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4716129/
https://www.ncbi.nlm.nih.gov/pubmed/26816499
http://dx.doi.org/10.5114/jcb.2015.56515
work_keys_str_mv AT akhtarimani dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation
AT pinoramiro dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation
AT scarborosarahb dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation
AT bassbarbaral dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation
AT miltenburgdarlenem dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation
AT butlerebrian dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation
AT tehbins dosimetricconsiderationsandearlyclinicalexperienceofacceleratedpartialbreastirradiationusingmultilumenapplicatorsinthesettingofbreastaugmentation