Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission

BACKGROUND: Precise and accurate field methods for body composition analyses in athletes are needed urgently. AIM: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). METHODS: Three observers captured US images of uncompres...

Descripción completa

Detalles Bibliográficos
Autores principales: Müller, Wolfram, Lohman, Timothy G, Stewart, Arthur D, Maughan, Ronald J, Meyer, Nanna L, Sardinha, Luis B, Kirihennedige, Nuwanee, Reguant-Closa, Alba, Risoul-Salas, Vanessa, Sundgot-Borgen, Jorunn, Ahammer, Helmut, Anderhuber, Friedrich, Fürhapter-Rieger, Alfred, Kainz, Philipp, Materna, Wilfried, Pilsl, Ulrike, Pirstinger, Wolfram, Ackland, Timothy R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4717413/
https://www.ncbi.nlm.nih.gov/pubmed/26702017
http://dx.doi.org/10.1136/bjsports-2015-095641
Descripción
Sumario:BACKGROUND: Precise and accurate field methods for body composition analyses in athletes are needed urgently. AIM: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). METHODS: Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements. RESULTS: Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R(2)=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ±1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured. CONCLUSIONS: A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately.