Cargando…
Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission
BACKGROUND: Precise and accurate field methods for body composition analyses in athletes are needed urgently. AIM: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). METHODS: Three observers captured US images of uncompres...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4717413/ https://www.ncbi.nlm.nih.gov/pubmed/26702017 http://dx.doi.org/10.1136/bjsports-2015-095641 |
_version_ | 1782410651980791808 |
---|---|
author | Müller, Wolfram Lohman, Timothy G Stewart, Arthur D Maughan, Ronald J Meyer, Nanna L Sardinha, Luis B Kirihennedige, Nuwanee Reguant-Closa, Alba Risoul-Salas, Vanessa Sundgot-Borgen, Jorunn Ahammer, Helmut Anderhuber, Friedrich Fürhapter-Rieger, Alfred Kainz, Philipp Materna, Wilfried Pilsl, Ulrike Pirstinger, Wolfram Ackland, Timothy R |
author_facet | Müller, Wolfram Lohman, Timothy G Stewart, Arthur D Maughan, Ronald J Meyer, Nanna L Sardinha, Luis B Kirihennedige, Nuwanee Reguant-Closa, Alba Risoul-Salas, Vanessa Sundgot-Borgen, Jorunn Ahammer, Helmut Anderhuber, Friedrich Fürhapter-Rieger, Alfred Kainz, Philipp Materna, Wilfried Pilsl, Ulrike Pirstinger, Wolfram Ackland, Timothy R |
author_sort | Müller, Wolfram |
collection | PubMed |
description | BACKGROUND: Precise and accurate field methods for body composition analyses in athletes are needed urgently. AIM: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). METHODS: Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements. RESULTS: Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R(2)=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ±1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured. CONCLUSIONS: A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately. |
format | Online Article Text |
id | pubmed-4717413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-47174132016-01-28 Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission Müller, Wolfram Lohman, Timothy G Stewart, Arthur D Maughan, Ronald J Meyer, Nanna L Sardinha, Luis B Kirihennedige, Nuwanee Reguant-Closa, Alba Risoul-Salas, Vanessa Sundgot-Borgen, Jorunn Ahammer, Helmut Anderhuber, Friedrich Fürhapter-Rieger, Alfred Kainz, Philipp Materna, Wilfried Pilsl, Ulrike Pirstinger, Wolfram Ackland, Timothy R Br J Sports Med Original Article BACKGROUND: Precise and accurate field methods for body composition analyses in athletes are needed urgently. AIM: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). METHODS: Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements. RESULTS: Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R(2)=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ±1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured. CONCLUSIONS: A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately. BMJ Publishing Group 2016-01 /pmc/articles/PMC4717413/ /pubmed/26702017 http://dx.doi.org/10.1136/bjsports-2015-095641 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Original Article Müller, Wolfram Lohman, Timothy G Stewart, Arthur D Maughan, Ronald J Meyer, Nanna L Sardinha, Luis B Kirihennedige, Nuwanee Reguant-Closa, Alba Risoul-Salas, Vanessa Sundgot-Borgen, Jorunn Ahammer, Helmut Anderhuber, Friedrich Fürhapter-Rieger, Alfred Kainz, Philipp Materna, Wilfried Pilsl, Ulrike Pirstinger, Wolfram Ackland, Timothy R Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission |
title | Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission |
title_full | Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission |
title_fullStr | Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission |
title_full_unstemmed | Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission |
title_short | Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission |
title_sort | subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the ioc medical commission |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4717413/ https://www.ncbi.nlm.nih.gov/pubmed/26702017 http://dx.doi.org/10.1136/bjsports-2015-095641 |
work_keys_str_mv | AT mullerwolfram subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT lohmantimothyg subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT stewartarthurd subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT maughanronaldj subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT meyernannal subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT sardinhaluisb subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT kirihennedigenuwanee subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT reguantclosaalba subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT risoulsalasvanessa subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT sundgotborgenjorunn subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT ahammerhelmut subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT anderhuberfriedrich subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT furhapterriegeralfred subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT kainzphilipp subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT maternawilfried subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT pilslulrike subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT pirstingerwolfram subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission AT acklandtimothyr subcutaneousfatpatterninginathletesselectionofappropriatesitesandstandardisationofanovelultrasoundmeasurementtechniqueadhocworkinggrouponbodycompositionhealthandperformanceundertheauspicesoftheiocmedicalcommission |